1. Introduction

The JUNCTEK KL-F series DC voltage and current meter/battery coulomb meter is a new type of coulomb meter designed to measure various parameters such as voltage, current, power, charge and discharge capacity, watt-hour, and time. It also features configurable protection functions including over-voltage, under-voltage, over-current, over-power, and over-temperature protection.

This device automatically identifies the direction of current flow and provides real-time battery capacity monitoring. It connects to a sampler in series with the battery's negative wire and communicates with a mobile phone APP via Bluetooth, allowing users to view measured data, control the meter, and perform firmware upgrades.

For a more detailed understanding, please refer to the official user manual PDF: KL-F Series User Manual (PDF).

2. Safety Information

Please read and understand all safety precautions before operating the meter to prevent personal injury or damage to the device.

General Safety Guidelines

  • Observe All Terminal Ratings: To avoid fire or shock hazards, always adhere to specified ratings and markers.
  • Use Proper Over-voltage Protection: Ensure no over-voltage reaches the product to prevent electric shock.
  • Do Not Operate Without Covers: Never operate the meter with covers or panels removed.
  • Do Not Insert Anything Into Air Outlet: Avoid inserting objects into the air outlet to prevent damage.
  • Avoid Circuit or Wire Exposure: Do not touch exposed junctions or components when the unit is powered on.
  • Do Not Operate With Suspected Failures: If damage is suspected, have the meter inspected by JUNCTEK authorized personnel.
  • Provide Adequate Ventilation: Ensure proper ventilation to prevent overheating. Regularly inspect the air outlet and fan.
  • Do Not Operate in Wet Conditions: Avoid humid environments to prevent short circuits or electric shock.
  • Do Not Operate in an Explosive Atmosphere: Never operate the meter in an explosive environment.
  • Keep Meter Surfaces Clean and Dry: Maintain clean and dry surfaces to ensure optimal performance.
  • Prevent Electrostatic Impact: Operate in an electrostatic discharge protective environment. Ground internal and external cable conductors before making connections.
  • Handle with Caution: Handle the device carefully during transportation to prevent damage to components.

Important Notices

  • Do not exceed the specified voltage and current range to prevent damage.
  • Ensure correct polarity; positive and negative poles cannot be reversed.
  • The meter's shell is fragile; avoid impacts and exposure to corrosive chemicals.
  • Store the meter in a dry environment at temperatures between -25℃ and 50℃.
  • Do not attempt to disassemble the meter, as this will void the warranty. Repairs must be performed by authorized personnel.
  • Avoid violent movement to prevent internal circuit damage. Contact the supplier if the meter malfunctions.

3. Specifications

ParameterKL140F Value
TypeVehicle Battery Tester
DIY SuppliesElectrical
OriginMainland China
CertificationCE
Battery IncludedNo
High-concerned chemicalNone
Sampling methodShunt
Voltage measurement range (External power supply)0-120V
Voltage measurement range (Self-powered)10-120V
Voltage resolution0.01V
Current measurement range0-400A
Current resolution0.1A
RelayNot provided, need to be purchased separately
Temperature measurement range-20-120 °C
Capacity display range0%~100%
Power measurement range0~72KW
Power resolution0.01W
Amp-hour measurement range0~9999.99AH
Capacity resolution0.001AH
Watt-hour measurement range0~999.99KWH
Watt-hour resolution0.01WH
Bluetooth communication distanceMax. 10 meters (without obstacles)
Voltage accuracy±2%+3 digits
Current accuracy±5%+10 digits
Sampling rate1 time/sec
Measuring module power consumptionAbout 0.4W
OPP (Over Power Protection)0-9999.99W
NCP (Negative Overcurrent Protection)0~50A/100A/400A/600A
OCP (Overcurrent Protection)0~50A/100A/400A/600A
OVP (Over Voltage Protection)0~120V/600V
LVP (Low Voltage Protection)0~120V/600V
OTP (Over Temperature Protection)0-120℃

4. Package Contents

The package for the KL140F Battery Monitor typically includes the following items:

Shipping List for JUNCTEK KL140F Battery Monitor

Image: Detailed view of the package contents for the KL140F Battery Monitor.

Textual Shipping List for JUNCTEK KL140F Battery Monitor

Image: Textual representation of the shipping list items.

  • Battery Monitor (1 pc)
  • Sampler (1 pc)
  • 4P Connection Cable (1 pc)
  • Sampler Mounting Plate (1 pc)
  • Temperature Sensor (1 pc)
  • 3P Terminal (1 pc)
  • 3P Connection Cable (1 pc)
  • Screws (4 pcs)
  • Spacers (4 pcs)

5. Setup and Installation

5.1. Physical Dimensions

Understanding the dimensions of the main unit and shunt is crucial for proper installation.

Dimensions of KL140F Battery Monitor and Shunt

Image: Dimensional drawing of the KL140F Battery Monitor and its shunt, showing measurements in millimeters.

5.2. Sampler Introduction

The sampler is a critical component for current detection. It connects to the measurement module via the sampler interface.

KL-F Series Sampler (100A example)

Image: A 100A sampler, illustrating its components and connection points.

  • Battery Negative Terminal (1): Connect the negative terminal of the battery to the screw marked 'GND' or 'BATT-'.
  • Sampler Interface (2): Connect this to the sampler interface of the measurement module for current measurement.

5.3. Wiring Methods

Correct wiring is essential for the proper functioning of the battery monitor. Refer to the diagrams and instructions below. A video demonstration of wiring instructions is available: Wiring Instructions Video.

5.3.1. Self-Powered Wiring Method (2-Wire)

This method is suitable if the battery voltage is within 10-120V. Set the power selection interface switch to '2W'.

Self-Powered Wiring Diagram for KL140F

Image: Diagram showing the self-powered wiring configuration for the KL140F Battery Monitor.

  • Connect the positive terminal of the battery to the power interface 'VSNS'. A 13-16AWG wire is sufficient.
  • Connect the negative pole of the battery to the screw marked 'BATT-' on the shunt.
  • Connect the negative poles of the charger and load to the other screw of the shunt. Use a copper nose for a firm connection.
  • Important: Pay attention to polarity; do not reverse connections.

5.3.2. External Power Supply Wiring Method (3-Wire)

This method is used when the external power supply voltage is 0-120V. Set the power selection interface switch to '3W'.

External Power Supply Wiring Diagram for KL140F

Image: Diagram illustrating the external power supply wiring configuration for the KL140F Battery Monitor.

  • Connect the positive pole of the external power supply to the power interface 'VEXT'.
  • Connect the negative pole of the external power supply to 'GND'.
  • Connect the positive pole of the battery to the measurement interface 'VSNS'.
  • The negative pole of the battery connects to 'BATT-' on the shunt.
  • The negative poles of the charger and load connect to the other screw of the shunt.
  • Important: Ensure positive and negative poles of the battery and external power supply are not connected incorrectly or reversed.

5.3.3. External Power Supply Wiring Method (Relay Control)

This method allows control over charging/discharging using a relay. The working power for the relay must be provided by an external power supply with the same voltage as the relay (e.g., 12V or 24V).

External Power Supply Wiring Diagram with Relay Control for KL140F

Image: Diagram detailing the external power supply wiring with relay control for the KL140F Battery Monitor.

  • Connect the relay's control ports to 'OUT' and 'VEXT' of the measurement module's Output Control.
  • Connect the positive pole of the external power supply to 'VEXT' of the Output Control, and its negative pole to 'GND'.
  • The negative pole of the battery connects to 'BATT-' on the shunt.
  • The negative poles of the charger and load connect to the other screw of the shunt.
  • When the relay is closed, the indicator light will be on; when disconnected, it will be off.

6. Operating Instructions

6.1. Mobile App Control

The KL140F Battery Monitor is primarily controlled and monitored via a mobile application available for Android and iOS devices.

6.1.1. App Download and Installation

  • Android App: Download from Google Play Store (search for "Juntek Celiangvat") or directly via http://68.168.132.244/app/KL/KL.apk. Requires Android 5.0 or above.
  • iOS App: Search for "KL Series" in the Apple App Store. Requires iOS 9.0 or above.
  • Installation: During installation, grant location services access. It is recommended to update to the latest software version for optimal performance.

Video demonstration for Android App installation and operation: Android App Demo Video.

Video demonstration for iOS App installation and operation: iOS App Demo Video.

Wireless Mobile App Control Interface

Image: Screenshots of the mobile app's main and settings interfaces, demonstrating wireless control and monitoring.

6.1.2. App Interface Overview

The app provides a comprehensive interface for monitoring and controlling the device.

  • Interface Title Bar: Navigate between Main, System Settings, and About Us sections.
  • Device Number: Displays after successful Bluetooth connection.
  • Communication Address: Range P00-P99.
  • Measured Voltage Value: Displays voltage from the power supply interface.
  • Remaining Battery Capacity: Calculated from preset capacity minus cumulative capacity.
  • Battery Capacity Percentage: Graphical representation of remaining capacity.
  • Preset Battery Capacity: User-defined total battery capacity.
  • Ambient Temperature: Displays current temperature from the external sensor.
  • Battery Life: Estimates battery life and charging time based on current.
  • Bluetooth Switch: Connects/disconnects the Bluetooth module.
  • Product Model: Displays after successful Bluetooth connection.
  • Control State: Allows control of the output state.
  • Measured Current Value: Displays actual current. Green for charging, brown for discharging.
  • Power: Displays measured current power in Watts.
  • Power Consumption: Accumulated electric energy in KW.h.
  • Clear Data: Resets time, power consumption, and accumulated capacity.
  • Cumulative Capacity: Accumulated charging/discharging capacity.

6.1.3. Main Interface Operations

  • Output State Control: Toggle the output state. Different states are displayed under various protection conditions.
  • Voltage/Current Fine Adjustment: Click on the voltage/current value to open a calibration pop-up. Default calibration is 100.
  • Voltage/Current Range Adjustment: Click on the voltage/current dial to adjust the display scale range.
  • Clear Data: Click the 'Clear data' button to reset time, power consumption, and accumulated capacity.
  • Percentage of Remaining Capacity: Click the battery icon to set the remaining capacity percentage.
  • Preset Battery Capacity: Click the 'setting' button next to preset battery capacity to input the actual AH value of your battery. This is crucial for accurate capacity monitoring.
  • Ambient Temperature Adjustment: Click on the ambient temperature display to fine-tune the temperature calibration.
  • Temperature Unit Switching: Click the ambient temperature value to switch between Celsius and Fahrenheit.

6.1.4. Protection Functions (Requires Relay)

The KL140F offers comprehensive protection features. A relay must be purchased separately and installed in the circuit to enable these functions.

Comprehensive Protection Features Diagram

Image: Diagram illustrating the various protection features: LVP, OPP, OTP, OCP/NCP, OVP.

  • Over Voltage Protection (OVP): Set a maximum voltage. If exceeded, the output turns off.
  • Under Voltage Protection (LVP): Set a minimum voltage. If dropped below, the output turns off.
  • Discharge Overcurrent Protection (OCP): Set a maximum discharge current. If exceeded, the output turns off.
  • Over Temperature Protection (OTP): Set a maximum temperature. If exceeded, the output turns off.
  • Charging Overcurrent Protection (NCP): Set a maximum charging current. If exceeded, the output turns off.
  • Over Power Protection (OPP): Set a maximum power. If exceeded, the output turns off.
  • Low Temperature Protection (LTP): Set a minimum temperature. If dropped below, the output turns off.
  • Protection Recovery Time: Configures the delay before the output recovers after a protection event.
  • Delay Protection Time: Configures a delay before protection activates.
  • Relay Mode: Select between normally open or normally closed relay types.
  • Low Volume Reminder: Sets a percentage threshold for a low capacity alert.

7. Maintenance

To ensure the longevity and accurate performance of your JUNCTEK KL140F Battery Monitor, follow these maintenance guidelines:

  • Keep Surfaces Clean and Dry: Regularly wipe the meter's surfaces with a soft, dry cloth to remove dust and moisture. Avoid using harsh chemicals or abrasive materials.
  • Ensure Adequate Ventilation: Periodically check that the air outlet is clear of obstructions and the fan (if present) is functioning correctly to prevent overheating.
  • Inspect Connections: Regularly inspect all wiring connections for tightness and signs of wear or corrosion. Loose connections can lead to inaccurate readings or malfunctions.
  • Software Updates: Keep the mobile application and device firmware updated to the latest versions to benefit from new features, improvements, and bug fixes.
  • Storage: When not in use for extended periods, store the device in a dry environment within the recommended temperature range (-25℃ to 50℃).
  • Avoid Physical Shock: Handle the device gently. Avoid dropping or subjecting it to strong vibrations, which can damage internal components.

8. Troubleshooting

If you encounter issues with your KL140F Battery Monitor, refer to the following common problems and solutions:

Common Issues and Solutions

  • Mobile APP cannot connect to Bluetooth or no display after power on:
    1. Check if the power supply and measurement module are correctly connected.
    2. Restart the instrument after checking connections.
    3. If the problem persists, contact JUNCTEK customer support.
  • Inaccurate Readings:
    1. Verify all wiring connections are secure and correct, especially for the shunt.
    2. Perform voltage and current fine adjustment via the mobile APP.
    3. Ensure the preset battery capacity in the APP matches the actual battery capacity.
  • Protection Function Not Working:
    1. Confirm that a relay is correctly installed and wired according to the relay control diagram.
    2. Check the protection settings in the mobile APP (OVP, LVP, OCP, etc.) and ensure they are enabled (not set to 0.00V/A/W/℃).
    3. Verify the relay mode (normally open/closed) matches your relay type.
  • App Crashing or Freezing:
    1. Ensure your mobile device's operating system and the KL-F App are up to date.
    2. Clear the app's cache or reinstall the app.
    3. Check for mobile phone model incompatibility (some older models or specific systems might have issues).

9. User Tips

  • Initial Setup for Capacity: When using a new battery or after replacing one, the displayed capacity might not be accurate. Fully discharge the battery, then set the remaining capacity percentage to 0% in the app. Fully charge the battery, then set the displayed capacity as the preset battery capacity for accurate monitoring.
  • Current Direction Indication: The app visually indicates current direction: green for charging and blue for discharging. This helps in quickly understanding battery status.
  • Pure Copper Shunt: The shunt and screws are made of pure copper, ensuring good electrical conductivity, low heat generation, and minimal power consumption in standby mode. This contributes to the accuracy and efficiency of the device.
  • Regular Calibration: Although the product has a self-calibration function, periodically checking and fine-tuning voltage and current values via the app can help maintain high accuracy over time.
  • Firmware Updates: Take advantage of the online firmware upgrade feature via the mobile app to ensure your device has the latest features and performance enhancements.
  • Protection with Relay: Remember that all advanced protection functions (OVP, LVP, OCP, etc.) require a separately purchased and correctly wired relay to physically disconnect the circuit. Without a relay, these functions will only trigger an alert in the app.

10. Warranty and Support

Warranty Information

JUNCTEK products are covered by P.R.C. patents. This document replaces all previously published documentation. Disassembly of the meter by unauthorized personnel will void the warranty.

Contact Us

If you have any problems or requirements regarding the use of this product or manual, please contact JUNCTEK directly:

For more product information, you can visit the JUNCTEK official website to download relevant manuals and resources.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.