1. Introduction
The KKMOON ET828P is a versatile 2-in-1 digital oscilloscope and multimeter designed to improve work efficiency for various electronic testing applications. This compact device features a 2.4-inch color screen, 1MHz bandwidth, and a 2.5Msps sampling rate, making it suitable for tasks ranging from car overhaul to production line diagnostics. It combines the functionality of a graphical oscilloscope with a comprehensive auto-ranging multimeter, offering measurements for AC/DC voltage, current, resistance, capacitance, frequency, duty cycle, diode, and continuity tests.

Figure 1: KKMOON ET828P Digital Oscilloscope Multimeter
2. Product Features
- 2-in-1 Functionality: Combines a digital oscilloscope and a multimeter for enhanced versatility.
- One-Button Oscilloscope: Allows direct waveform measurement without the need for an external oscilloscope probe.
- Color Display: Features a 2.4-inch (320*240 pixels) LCM color screen with white backlight for clear readings.
- Comprehensive Multimeter Functions: Measures AC/DC voltage, AC/DC current, resistance, capacitance, frequency, duty cycle, diode test, and continuity test.
- Mass Storage: Capable of storing 100 sets of data and 10 waveform records.
- Triple Safety Protection: Includes double insurance tubes (750mA/250V, 10A/250V), a beep warning for input voltage exceeding 24V, and an over-range beep warning. Automatic circuit cut-off for voltage overload.
- Simultaneous Display: Shows historical records and real-time data on the same screen for easy comparison.
- User-Friendly Interface: Equipped with silicone buttons and a sensitive function dial for accurate gear selection.
- Ergonomic Design: Features a back bracket that tilts at 60° for convenient viewing.
- Auto-Sleep Function: Automatically enters sleep mode after 15 minutes of inactivity to conserve battery.
- Auto-Capture Waveform: One-touch automatic waveform capture function.
- REL+MAX Function: Provides relative value measurement and MAX/MIN test for accurate data analysis.
- Trigger Modes: Supports Auto, Normal, and Single trigger modes for oscilloscope functionality.

Figure 2: Key Advantages of the ET828P
3. Package Contents
Please check the package contents upon receipt to ensure all items are present and undamaged:
- 1 x KKMOON ET828P Graphical Multimeter
- 1 x Pair of Test Pens (Test Leads)
- 1 x Protective Bag
- 1 x User Manual

Figure 3: Included Accessories
4. Setup
4.1 Battery Installation
- Ensure the device is powered off.
- Locate the battery compartment cover on the back of the multimeter.
- Open the battery compartment cover.
- Insert 3 AA batteries (not included) into the compartment, observing the correct polarity (+/-) as indicated.
- Close the battery compartment cover securely.
4.2 Connecting Test Leads
- Identify the red and black test leads.
- Insert the black test lead into the 'COM' (Common) input jack.
- Insert the red test lead into the appropriate input jack for your measurement:
- For voltage, resistance, capacitance, frequency, duty cycle, and diode tests, insert into the 'VΩCxHz%' jack.
- For current measurements up to 600mA, insert into the 'mA' jack.
- For current measurements up to 10A, insert into the '10A' jack.
- Ensure the connections are firm before proceeding with any measurements.
5. Operating Instructions
5.1 Power On/Off
To power on the device, rotate the central function dial from the 'OFF' position to any desired measurement function. To power off, rotate the dial back to the 'OFF' position.
5.2 Multimeter Mode Selection
Rotate the central function dial to select the desired measurement mode:
- V~: AC Voltage measurement
- V=: DC Voltage measurement
- Cx: Capacitance measurement
- Hz%: Frequency and Duty Cycle measurement
- mA~: AC Current (milliampere) measurement
- mA=: DC Current (milliampere) measurement
- 10A~: AC Current (ampere) measurement
- 10A=: DC Current (ampere) measurement
- Ω: Resistance measurement
- Diode/Continuity: Diode test and Continuity test
The device features automatic ranging for most multimeter functions. The 2.4-inch color screen will display the current measurement, range, and other relevant data.

Figure 4: Multimeter Display Elements

Figure 5: Examples of Measurement Displays
5.3 Oscilloscope Mode
To enter Oscilloscope mode, long press the 'R' key (Function 1 button) while the device is on. The screen will switch to display waveforms.

Figure 6: Entering Oscilloscope Mode
5.3.1 Waveform Capture (Auto-Capture)
The device features a one-touch automatic waveform capture function. In oscilloscope mode, the device can automatically capture and display waveforms. The display will show parameters like VP-P, average value, effective value, frequency, time base, and amplitude.

Figure 7: Auto-Capture Waveform Examples
5.3.2 Trigger Modes
The oscilloscope supports three trigger modes:
- Auto Mode: If no trigger signal is detected, the device will still acquire and display waveform data.
- Normal Mode: Waveform data is acquired only when a trigger signal is detected.
- Single Mode: Acquires a single waveform data set upon detecting a trigger signal and then stops.

Figure 8: Trigger Modes
5.4 Data Storage and Recall
The device can store up to 100 sets of measurement data and 10 waveform records. Use the function buttons (F1, F2, F3, F4) to navigate menus for saving and recalling data. Refer to the on-screen prompts for specific operations.

Figure 9: Mass Storage Feature
5.5 REL+MAX Function
The REL (Relative Value) function helps eliminate lead resistance and distributed capacitance, improving measurement accuracy. The MAX/MIN test function allows for easy analysis of data by displaying the maximum and minimum values recorded during a measurement session.

Figure 10: REL+MAX Function
6. Maintenance
6.1 Cleaning
To clean the device, use a soft, dry cloth. Do not use abrasive cleaners or solvents, as they may damage the casing or screen.
6.2 Fuse Replacement
The device is equipped with double insurance tubes: 750mA/250V and 10A/250V. If a fuse blows, ensure the device is powered off and disconnect all test leads before attempting replacement. Replace with fuses of the exact same specifications to maintain safety and functionality.
6.3 Battery Replacement
When the battery indicator shows low power, replace the 3 AA batteries as described in Section 4.1. Always use fresh batteries of the same type.
6.4 Storage
Store the device in a dry environment with temperatures between -10℃ and 60℃ and relative humidity below 90% RH. Avoid direct sunlight and extreme temperatures.
7. Troubleshooting
- No Display: Check if the batteries are correctly installed and have sufficient charge. Replace batteries if necessary. Ensure the function dial is not in the 'OFF' position.
- Incorrect Readings: Verify that the test leads are correctly connected to the appropriate input jacks for the selected measurement. Ensure the function dial is set to the correct measurement mode. Check for damaged test leads.
- Beep Warning:
- If the input voltage is greater than 24V, a beep warning will sound. Disconnect immediately to prevent damage.
- If an input over-range occurs, a beep warning will sound. Adjust the range or check the input signal.
- Device Not Responding: Try turning the device off and on again. If the issue persists, remove and reinsert the batteries.

Figure 11: Safety Features and Warnings
8. Specifications
| Category | Parameter | Value |
|---|---|---|
| General | Material | ABS |
| Color | Black | |
| Display | 320*240 LCM | |
| Display Area | Approx. 2.4 inches | |
| Backlight | White | |
| Input Resistance | 10MΩ | |
| Battery | 3 * AA battery (not included) | |
| Power Consumption | About 75mA | |
| Item Size | 160 * 83 * 32mm / 6.3 * 3.3 * 1.3in | |
| Item Weight | 195g / 6.9ounce (without battery) | |
| Oscilloscope | Bandwidth | ACV / 10MHz |
| Max. Real-time Sampling Rate | 50Msps | |
| Number of Channels | 1 | |
| Vertical Sensitivity Range | 500mV- 200V/div | |
| Timebase Range | 200ns - 10s/div | |
| Vertical Range Accuracy | ±(5% + 0.2div) | |
| Time Base Accuracy | ±(0.01% + 0.1div) | |
| Trigger Mode | Auto / Single / Normal | |
| Multimeter | DC Voltage Range | 600mV/6V/60V/600V/1000V (Uncertainty: ±1.2%rdg + 5dgt) |
| AC Voltage Range | 600mV/6V/60V/600V/750V (Uncertainty: ±1.2%rdg + 5dgt (50Hz ~60Hz), ±1.5%rdg + 5dgt (100-400Hz)) | |
| DC Current Range | 60mA/600mA/6A /10A (Uncertainty: ±1.2%rdg + 5dgt (±1.5%rdg + 5dgt)) | |
| AC Current Range | 60mA/600mA/6A /10A (Uncertainty: ±1.2%rdg + 5dgt (±2%rdg + 10dgt)) | |
| Resistance Range | 60Ω/6kΩ/60kΩ/600kΩ/6MΩ/60MΩ (Uncertainty: ±(1.0%rdg + 5dgt)± (3.0%rdg + 5dgt) /60MΩ) | |
| Capacitance Range | 99.99nF/999.9nF/9.99μF/99.99μF/999.9μF (Uncertainty: ±3.0% rdg+10dgt) | |
| Frequency Range | 1.000Hz~20.00MHz (Uncertainty: ±0.5% rdg+5dgt) | |
| Duty Cycle Range | 0.1%~99.9% (Uncertainty: 1.0% rdg+5dgt) | |
| Diode Test | Voltage is about 5V, test current is about 1.5mA | |
| Continuity Test | Judgment resistance about: <50Ω beep | |
| Environmental | Use Environment | 0~40℃, <75%RH |
| Storage Environment | -10~60℃, <90%RH | |
| Automatic Sleep | 15 minutes or disabled |

Figure 12: Detailed Product Parameters
9. User Tips
- For stable readings, especially in resistance and capacitance measurements, ensure good contact with the test points and minimize external interference.
- When measuring current, always connect the meter in series with the circuit and ensure the correct current jack (mA or 10A) is used to avoid blowing fuses.
- Utilize the 'REL' function for precise measurements by nullifying lead resistance, particularly for small resistance values.
- The auto-sleep function can be disabled if continuous operation is required, though this will increase battery consumption.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.