Aideepen Relay Module

Rate this product if you’ve used it
Contents

User Manual: 12V Battery Low Voltage Cut-off and Recovery Protection Module

Model: Relay Module | Brand: Aideepen

1. Introduction and Overview

This 12V Battery Low Voltage Cut-off and Automatic Recovery Protection Module is designed to safeguard your 12V battery from over-discharge, thereby extending its service life. It functions by automatically disconnecting the load power supply when the battery voltage drops below a user-defined threshold and reconnecting it when the voltage recovers to another set value.

Key features include a wide range of applications, compact size, ease of use, a robust 10A relay, and stable performance. The module is equipped with LED indicators to clearly show the connection status of the load.

Aideepen 12V Battery Low Voltage Cut-off Module with labeled components
Figure 1: Product overview with labeled components including load terminal, battery terminal, 10A relay, load ON indicator, force start interface, and voltage regulation potentiometers.

2. Specifications

FeatureSpecification
Product NameBattery Undervoltage Protection Module
BrandAideepen
Model NumberRelay Module
Power SourceDC
TheoryVoltage relay
Applicable Battery12V battery
Voltage12V
Output TypeSwitch
Voltage Error±0.1V
Product Load10A
Contact LoadLow Power
Protect FeatureSealed
UseGeneral Purpose
Product Size (L*W*H)50mm * 30mm * 18mm
Installation Size24MM (2 holes/3mm)
Product Weight20g

For a detailed user manual in PDF format, please refer to the official document.

3. Package Contents

  • 1 x 12V Battery Undervoltage Automatic Recovery Module

4. Setup Instructions

Follow these steps to correctly connect the battery undervoltage protection module:

  1. Connect the Battery: Connect your 12V battery to the terminals labeled "BAT +" (positive) and "BAT -" (negative) on the module. Ensure correct polarity.
  2. Connect the Load: Connect your electrical load (the device you want to protect) to the terminals labeled "OUT +" (positive) and "OUT -" (negative) on the module. Ensure correct polarity.
  3. Optional Force Start Interface: The module includes a PH2.0-2P socket for a force start interface. If a 2P socket is connected and turned on, the load will be forced to start. Note that the product is not equipped with a physical force start switch.
Wiring diagram for 12V Battery Low Voltage Cut-off Module
Figure 2: Wiring diagram showing connections for the 12V battery and the load.

5. Operating Instructions

Once connected, the module operates automatically:

  • The module continuously monitors the battery voltage.
  • If the battery voltage drops below the set undervoltage disconnection value, the module will automatically cut off the power supply to the load.
  • When the battery voltage rises to the set under-voltage recovery value (e.g., after charging), the module will automatically restart the load.
  • An integrated LED indicator (labeled "Load ON (Output) Indicator" in Figure 1) will show whether the load is currently connected or disconnected.

6. Adjustment and Calibration

The module features two potentiometers for adjusting the undervoltage shutdown and recovery parameters. Exercise caution and make small adjustments.

Detailed instructions for adjusting undervoltage shutdown and recovery potentiometers
Figure 3: Potentiometer adjustment guide for undervoltage shutdown and recovery.

6.1. Undervoltage Shutdown Voltage Regulation (Load Off Voltage)

  • Potentiometer: The potentiometer labeled '612T0' (or similar, see Figure 1 and 3) regulates the load off voltage.
  • Clockwise Adjustment: Increases the voltage at which the load is turned off.
  • Counter-clockwise Adjustment: Decreases the voltage at which the load is turned off.
  • Factory Default: The load off factory default voltage is approximately 11V.
  • Adjustment Range: Adjusting half a circle clockwise adds approximately 0.4V. Adjusting half a turn counter-clockwise subtracts approximately 0.4V.
  • Important Note: Do not adjust more than two full turns for a 12V battery. Exceeding two turns is not a standard 12V battery usage parameter.

6.2. Under-voltage Start-up Voltage Regulation (Load Recovery Voltage)

  • Potentiometer: The potentiometer labeled 'W103' (or similar, see Figure 1 and 3) regulates the load recovery voltage.
  • Clockwise Adjustment: Increases the voltage at which the load is turned back on.
  • Counter-clockwise Adjustment: Decreases the voltage at which the load is turned back on.
  • Factory Default: The load starts at a factory default voltage of approximately 12.5V.
  • Adjustment Range: Adjusting half a turn clockwise adds approximately 0.5V. Adjusting half a turn counter-clockwise subtracts approximately 0.5V.
  • Important Note: Do not adjust more than two full turns for a 12V battery. Exceeding two turns is not a standard 12V battery usage parameter.
  • Example: If you set the undervoltage disconnection to 10.5V, the under-voltage start-up can be set to activate between 10.5V and 14.4V, depending on your specific charger and usage requirements.

Caution: Always make small adjustments to the potentiometers and verify the voltage settings with a multimeter to prevent damage to your battery or connected load.

7. Maintenance

This module requires minimal maintenance. To ensure optimal performance and longevity:

  • Keep the module clean and free from dust and debris.
  • Ensure it is installed in a dry environment, away from moisture and extreme temperatures.
  • Periodically inspect all wiring connections to ensure they are secure and free from corrosion.
  • Avoid exposing the module to strong vibrations or mechanical shock.

8. Troubleshooting

ProblemPossible CauseSolution
Load does not disconnect when battery voltage is low.Undervoltage shutdown threshold set too low, or module malfunction.Verify the undervoltage shutdown setting (Load Off Voltage) using a multimeter. Adjust potentiometer if necessary. Check wiring.
Load does not reconnect when battery voltage recovers.Under-voltage recovery threshold set too high, or battery voltage not yet reached threshold.Verify the under-voltage recovery setting (Load Recovery Voltage). Ensure battery voltage is above this threshold. Adjust potentiometer if needed.
Load ON (Output) Indicator LED is off when load should be active.Load is disconnected, or LED malfunction.Check battery voltage and module settings. If voltage is sufficient and settings are correct, inspect the LED or module for damage.
Module is not functioning at all.No power to module, incorrect wiring, or module damage.Check all power connections to the battery. Verify wiring according to the setup instructions. If still unresponsive, the module may be faulty.

9. User Tips

  • When adjusting the potentiometers, use a small, non-conductive screwdriver and turn them slowly. Small changes can have a significant effect on the voltage thresholds.
  • Always use a reliable multimeter to measure the battery voltage and verify the cut-off and recovery points after making adjustments.
  • Consider the specific discharge characteristics of your 12V battery type (e.g., lead-acid, LiFePO4) when setting the undervoltage thresholds to maximize battery life.

10. Warranty and Support

For any issues, technical support, or warranty claims, please contact the seller or manufacturer directly. Keep your purchase records for reference.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?