KKMOON KKM618

Contents

KKMOON KKM618 Handheld Cable Tester User Manual

Model: KKM618 | Brand: KKMOON

1. Introduction

The KKMOON KKM618 is a versatile handheld device combining cable tracing, cable length measurement, POE testing, and comprehensive multimeter functions. Designed for professionals and enthusiasts in laboratories, factories, and network installation, it offers rapid and precise diagnostics for various metal cables, including network cables, telephone lines, and BNC cables. Its advanced features allow for real-time measurement of cable length, detection of short circuits and breaks, and efficient identification of target cables within complex bundles.

2. Product Overview

2.1. Package Contents

The KKM618 package typically includes the following items:

  • 1 x Host Unit (Main Tester)
  • 1 x Wire Tracker Receiver
  • 1 x User Manual
  • 1 x Crocodile Clip Line
  • 1 x Network Cable
  • 1 x Recharging Line (for Host Unit)
  • 1 x Temperature Probe
  • 1 x Multimeter Probes (Red and Black)
  • 1 x Storage Bag

Note: The ID pairing function requires a remote ID mapping accessory, which is sold separately and not included in this standard set.

KKM618 Packing Contents
Figure 2.1: KKM618 Packing Contents. Shows the main unit, receiver, storage bag, color box, crocodile clip line, network cable, charging line, temperature probe, multimeter probe, and user manual.

2.2. Key Features

  • Cable Tracing: Quickly locate target cables in bundles.
  • Cable Length Test: Measures length and identifies cable conditions (normal, short circuit, open circuit) for network, telephone, and BNC cables up to 500 meters.
  • POE Test: Checks cable mapping polarity and voltage of POE network switches.
  • Multimeter Functions: Measures DC/AC voltage, DC/AC current, resistance, continuity, diode, and temperature.
  • Digital/Vibration Tracing: Offers both digital tracing and a vibration mode for enhanced sensitivity.
  • LCD Display with Flashlight: Large, clear LCD for easy reading and an integrated flashlight for low-light conditions.
  • NCV Detection: Non-Contact Voltage detection.
  • Rechargeable Host Unit: Built-in 1250mAh lithium battery for the main unit.

2.3. Device Layout and Controls

KKM618 Function Display Diagram
Figure 2.2: KKM618 Function Display. Labels key components of the main unit and receiver, including Network Cable Jack, Display, Push Buttons (LENGTH, TEST, SCAN, POE, DMM), Tracing Sensor, Flashlight, Sound/Sensitivity Adjusting Wheel, Flashlight Switch, SCAN Button, Indicators, RJ45 Cable Jack, DMM Input Jack, Charging Port/LED Lighting/NCV Sensor/Length Measurement Port.
  1. Network Cable Jack: For connecting network cables to the main unit.
  2. Display: LCD screen showing measurement results and mode information.
  3. Push Buttons (LENGTH, TEST, SCAN, POE, DMM): Used to select different testing modes.
  4. Tracing Sensor: On the receiver, used to detect signals from the main unit.
  5. Flashlight: Integrated light on the receiver for illuminating work areas.
  6. Sound/Sensitivity Adjusting Wheel: On the receiver, adjusts the tracing sensitivity and sound volume.
  7. Flashlight Switch: Activates the receiver's flashlight.
  8. SCAN Button: Initiates cable scanning/tracing.
  9. Indicators: LED indicators on the receiver for signal strength and cable status.
  10. RJ45 Cable Jack: On the receiver, for connecting RJ45 cables during tracing.
  11. DMM Input Jack: For connecting multimeter probes (KKM618 only).
  12. Charging Port/LED Lighting/NCV Sensor/Length Measurement Port: Multi-function port on the main unit.

WARNING: The product will be damaged if the Length Measurement Port is connected to PoE or any energized devices.

3. Setup

3.1. Powering the Devices

  • Host Unit: The main unit has a built-in 1250mAh lithium battery. Before first use, ensure it is fully charged using the provided recharging line. Connect the recharging line to the charging port on the main unit and a suitable USB power source.
  • Receiver: The receiver requires one 9V battery (not included). Open the battery compartment on the back of the receiver and insert a fresh 9V battery, observing polarity.

3.2. Connecting Probes and Cables

  • Network Cables: For cable length measurement or mapping, connect one end of the network cable to the Network Cable Jack on the main unit.
  • Multimeter Probes (KKM618 only): For multimeter functions, insert the red and black multimeter probes into the DMM Input Jacks on the main unit, matching the polarity.
  • Crocodile Clip Line: For tracing non-RJ45 cables, connect the crocodile clip line to the appropriate port on the main unit.

4. Operating Instructions

4.1. Cable Tracing Function

This function helps locate a specific cable among many. It can be used for telephone systems, computer networks, BNC cables, and other metal network cables.

  1. Connect the cable to be traced to the main unit using the appropriate connector (e.g., Network Cable Jack or Crocodile Clip Line).
  2. Turn on both the main unit and the receiver.
  3. Select the tracing mode on the main unit (usually by pressing the 'SCAN' button or rotating the 'MODE' dial on the receiver).
  4. Use the receiver's tracing sensor to scan along the cables. The receiver will emit a sound, and indicators will light up, becoming stronger as you approach the target cable.
  5. Adjust the Sound/Sensitivity Adjusting Wheel on the receiver for optimal detection.

4.2. Cable Length Measurement

The KKM618 can measure the length of network cables, telephone lines, and BNC cables up to 500 meters and identify their condition.

  1. Connect one end of the cable to the Network Cable Jack on the main unit.
  2. Press the 'LENGTH' button on the main unit to enter length measurement mode.
  3. The display will show the cable length and the status of each wire pair (1-2, 3-6, 4-5, 7-8).
  4. Interpret the display:
    • Normal: Indicates a healthy cable.
    • Short Circuit: Shows a short between wires.
    • Open Circuit: Indicates a break in the wire.
  5. Press the 'TEST' button to cycle through different cable types (8P8C, 4P4C, BNC) if needed.
Wire Length Measurement Examples
Figure 4.1: Wire Length Measurement Examples. Illustrates display readings for Normal, Short Circuit, and Open Circuit cable conditions.

4.3. POE Test

This function allows you to check the Power over Ethernet (POE) status of network switches, including voltage and polarity.

  1. Connect the network cable from the POE switch to the Network Cable Jack on the main unit.
  2. Press the 'POE' button on the main unit.
  3. The display will show the POE voltage and indicate which pins are providing power, along with their polarity.
POE Test Display
Figure 4.2: POE Test Display. Shows an example reading of 48V, indicating pins 1, 2, 3, 6 providing power, and digital flicker for positive polarity.

4.4. Multimeter Functions (KKM618 Only)

The KKM618 integrates a full-featured digital multimeter.

  1. Connect the multimeter probes to the DMM Input Jacks on the main unit.
  2. Press the 'DMM' button to enter multimeter mode.
  3. Use the main unit's buttons to select the desired measurement:
    • Direct Current Voltage: Measure DC voltage.
    • AC Voltage: Measure AC voltage.
    • Direct Current Current: Measure DC current.
    • AC Current: Measure AC current.
    • Resistance: Measure electrical resistance.
    • Continuity: Test for continuity (buzzer beeps if resistance is < 50Ω).
    • Diode: Test diode functionality.
    • Temperature: Use the temperature probe to measure temperature (K-type).
Multimeter Functions
Figure 4.3: Multimeter Functions. Demonstrates Continuity, Temperature, NCV, and Current measurement modes.

4.5. Switch Port Flicker

This feature assists in identifying network cables connected to a switch.

  1. Connect the network cable to the main unit.
  2. Activate the alignment function (refer to the main unit's display for specific mode).
  3. The sequence light corresponding to the switch port will blink once every 2 seconds, allowing you to directly identify the connected network wire.
Switch Port Flicker
Figure 4.4: Switch Port Flicker. Shows the main unit connected to a network switch, with the corresponding port light blinking.

5. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place, away from direct sunlight and extreme temperatures. Use the provided storage bag for protection.
  • Battery Replacement (Receiver): Replace the 9V battery in the receiver when the low battery indicator appears or when performance degrades.
  • Charging (Host Unit): Recharge the host unit regularly to maintain battery health. Avoid fully discharging the battery for extended periods.
  • General Care: Avoid dropping the device or exposing it to excessive moisture. Ensure all connections are secure before operation.

6. Troubleshooting

  • No Power: Check the host unit's battery charge level and recharge if necessary. For the receiver, ensure the 9V battery is correctly installed and not depleted.
  • Inaccurate Readings: Ensure all cable connections are secure and clean. Verify that the correct mode is selected for the test being performed.
  • No Signal During Tracing: Increase the sensitivity on the receiver using the adjusting wheel. Ensure the main unit is transmitting a signal and the cable is properly connected.
  • Damage Warning: Remember the warning: connecting the Length Measurement Port to PoE or any energized devices will damage the product. Always ensure circuits are de-energized before connecting for length measurement.

7. Specifications

FeatureSpecification (KKM618)
MaterialABS
Analogue TracingYes
Switch Tracing (w/PoE)Yes
Cable MappingYes
Switch Indicators FlashingYes
Noisy Free Digital TracingDigital/Vibration
PoE Voltage MeasuringVoltage Polarity
Analogue BargraphYes
NCV DetectionYes
Network Cable Length Measure500M
Host PowerBuilt-in lithium battery, 1250mAh
Receiver Power1 * 9V battery (NOT INCLUDED)
Package Size218 * 158 * 50mm
Package Weight585g / 1.3lb

7.1. Multimeter Specifications (KKM618 Only)

MeasurementRange & Accuracy
Direct Current Voltage400mV~1000V ±(0.8%+3)
AC Voltage4V~400V ±(1.5%+5)
Direct Current Current1.0A~10.0A ±(1.2%+4)
AC Current1.0A~10.0A ±(2.0%+5)
Resistance200Ω~20MΩ ±(2%+6)
Continuity< 50Ω buzzers beeps
DiodeYes
Temperature (K-type)-20~1000°C ±(2.0%+15)

8. User Tips

  • Battery Life: For the receiver, always carry a spare 9V battery, as it is not rechargeable.
  • Safety First: Before performing any tests, especially those involving cable length measurement, ensure the cable is disconnected from any energized devices or PoE sources to prevent damage to the tester.
  • Optimal Tracing: When tracing, start with a lower sensitivity setting on the receiver and gradually increase it until the signal is clear, to avoid interference from nearby cables.
  • Cable Type Selection: For accurate length measurements, ensure you select the correct cable type (8P8C, 4P4C, BNC) using the 'TEST' button.

9. Warranty and Support

For warranty information and technical support, please refer to the documentation provided by your retailer or contact KKMOON customer service directly. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.