1. Introduction
The Aideepen XH-W3002 is a versatile microcomputer LED digital temperature controller designed for various industrial control applications. It features a high-brightness digital display for clear readability, a wide temperature control range, and precise temperature control accuracy. This manual provides detailed instructions for installation, setup, operation, and troubleshooting to ensure safe and effective use of your device.
2. Features
- Clear Digital Display: High-brightness digital tube ensures clear readability day or night.
- Replaceable Sensor: The 2P terminal allows for easy replacement of the temperature sensor.
- Durable Construction: Made with a 1.8mm thick ABS material shell, offering high mechanical strength, good electrical performance, and anti-aging properties.
- Wide Temperature Range: Controls temperatures from -50°C to 110°C.
- High Accuracy: Features 0.1°C temperature control accuracy.
- Convenient Wiring: Designed with wiring input and output for easy integration into various industrial control equipment.
- Robust Wiring: Multi-strand wire 300V/20A excess configuration for safe and reliable operation.
3. Specifications
| Attribute | Value |
|---|---|
| Product Name | Microcomputer temperature controller |
| Product Model | XH-W3002 |
| Temperature Measurement Range | -50 to 110℃ |
| Temperature Control Range | -50 to 110℃ |
| Temperature Measurement Accuracy | ±0.2℃ |
| Temperature Control Accuracy | ±0.1℃ |
| Measurement Input | NTC10K L=1 meter waterproof probe |
| Input Power | DC12V/24V, AC110V-220V |
| Output Power | 120W (for 12V), 240W (for 24V), 1500W (for 110V-220V) |
| Output Type | Direct output |
| Output Capacity | Max 10A |
| Installation Hole Distance | 73mm (diameter 4mm) |
| Appearance Size | 60*45*31mm |
| Certification | CE |
| Display Size | 1.9 Inches & Under |
4. Safety Warnings
WARNING: Improper wiring can lead to electric shock, fire, or damage to the device and connected equipment. Always ensure power is disconnected before wiring.
- Ensure the input voltage matches the specified voltage for your model (DC12V, DC24V, or AC110V-220V).
- Do not exceed the maximum output capacity of 10A.
- When connecting the output, ensure the load is properly connected before powering on to prevent potential short circuits or ignition due to exposed wires.
- Installation should be performed by qualified personnel if you are unsure about electrical wiring.
- Keep the device away from water and high humidity environments unless the probe is specifically designed for such conditions.
5. Installation and Wiring
The XH-W3002 is designed for easy installation with side holes for fixation. Ensure you have selected the correct voltage version for your application.
5.1 Physical Installation
The controller features a 1.8mm thick ABS material shell with side holes for easy mounting. The installation hole distance is 73mm with a diameter of 4mm for screws. The overall appearance size is 60*45*31mm.

5.2 Wiring Diagrams
Important: Always disconnect power before performing any wiring. Ensure all connections are secure to prevent hazards.
5.2.1 220V Wiring Method
For the AC110V-220V version, connect the power supply and the load as shown in the diagram below. The output is direct, meaning the controller acts as a switch for the load.

5.2.2 12V/24V Wiring Method
For the DC12V or DC24V versions, connect the DC power supply (e.g., battery) and the load as illustrated. Note that the W3002 is a direct output device. If the output is not connected to a load, avoid powering it on to prevent potential short circuits or ignition due to exposed wires.

6. Setup and Configuration
The XH-W3002 controller has a simple interface with a digital display, a "Settings" button, an "Up" button, and a "Down" button. The "OUT" indicator lights up when the output is active.

6.1 Setup Parameter Table
| Code | Illustrate | Set Range | Factory Settings |
|---|---|---|---|
| P0 | Start temperature | -50~110℃ | 00 |
| P1 | Stop temperature | -50~110℃ | 00 |
| P2 | Temperature correction | -10~10℃ | 0℃ |
| P3 | Delay start | 0~10 Minutes | 0 Minutes |
6.2 Setting Parameters
To enter the internal menu, press the "Settings" button once. The default display will be P0. Use the "Up" and "Down" buttons to navigate between parameters (P0, P1, P2, P3) and to adjust their values.
6.2.1 P0: Set Start Temperature
- Press the "Settings" button once. The display will show "P0".
- Press the "Settings" button again. The current P0 value will flash.
- Use the "Up" and "Down" buttons to set your desired start temperature.
- The setting will automatically save after a few seconds of inactivity, or you can press the "Settings" button again to confirm and exit.
6.2.2 P1: Set Stop Temperature
- Press the "Settings" button once to enter the internal menu.
- Use the "Up" or "Down" buttons to navigate to "P1".
- Press the "Settings" button again. The current P1 value will flash.
- Use the "Up" and "Down" buttons to set your desired stop temperature.
- The setting will automatically save after a few seconds of inactivity, or you can press the "Settings" button again to confirm and exit.
6.2.3 P2: Set Temperature Correction
This parameter allows you to calibrate the temperature reading if there's a discrepancy between the displayed temperature and the actual temperature.
- Enter the internal menu and navigate to "P2".
- Press the "Settings" button again. The current P2 value will flash.
- Use the "Up" and "Down" buttons to set the calibration value.
- If the detected temperature is 0.5°C higher than actual, set P2 to -0.5°C.
- If the detected temperature is 1°C lower than actual, set P2 to 1°C.
- The formula for corrected temperature is: Detected Temperature ± Corrected Temperature = Actual Temperature.
6.2.4 P3: Set Delay Start
Delay start is typically used for compressor refrigeration to protect the compressor. This value is set in minutes.
- Enter the internal menu and navigate to "P3".
- Press the "Settings" button again. The current P3 value will flash.
- Use the "Up" and "Down" buttons to set the desired delay time (0-10 minutes).
- For refrigerator freezers, the general setting value is 3-6 minutes, depending on the compressor's back pressure. If you are not controlling a compressor or do not need this function, you can skip this setting.
7. Operating Instructions
Once the controller is wired and configured, it will automatically regulate the temperature based on your P0 (start temperature) and P1 (stop temperature) settings. The "OUT" indicator will illuminate when the output is active (e.g., heating or cooling device is on).
The following video demonstrates the basic operation, including setting the stop temperature and observing the fan stopping when the set temperature is exceeded.
8. User Tips
- Ease of Adjustment: Users have found the device easy to adjust, making it convenient for quick temperature changes.
- Voltage Compatibility: While the device supports 12V, 24V, and 220V, some users have reported issues with the 24V version burning out, especially when connected to charging batteries or systems with voltage spikes. Consider using a voltage regulator or a version with a wider operating range for 24V applications, or ensure your 24V supply is stable.
- Load Management: Be mindful of the load connected. Even small loads like a 2.4W fan have been associated with failures in some 24V units if the voltage is unstable.
9. Troubleshooting
- Device not powering on or display is blank:
- Check power connections: Ensure the input power is correctly wired and matches the device's voltage (12V, 24V, or 110V-220V).
- Verify power source: Test your power source to ensure it is supplying the correct voltage.
- Inspect internal components: If comfortable and qualified, check for any visible damage to internal components (e.g., burned resistors, as reported by some users for 24V units).
- Incorrect temperature readings:
- Check sensor connection: Ensure the NTC10K waterproof probe is securely connected to the 2P terminal.
- Sensor damage: The sensor might be damaged. Try replacing it if you have a spare.
- Apply temperature correction (P2): Use the P2 setting to calibrate the temperature if there's a consistent offset.
- Output (load) not switching:
- Verify P0/P1 settings: Ensure your start (P0) and stop (P1) temperatures are set correctly for your desired operation (heating or cooling).
- Check load connection: Make sure the load is properly wired to the output terminals and is not faulty.
- Output capacity: Ensure the load's current draw does not exceed the maximum 10A output capacity.
- Delay start (P3): If P3 is set, there might be a delay before the output activates.
- Device burning out, especially 24V models:
- Voltage Stability: The 24V version may be sensitive to voltage fluctuations or spikes, particularly when connected to unstable power sources like charging batteries. Consider adding a voltage regulator or using a power supply with better regulation.
- Overload: Even small loads can cause issues if the internal components are stressed by unstable voltage. Ensure the load is well within the device's specifications.
- Heat Dissipation: Ensure adequate ventilation around the controller to prevent overheating.
10. Maintenance
- Cleaning: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Probe Care: Handle the temperature probe carefully. Avoid bending or damaging the cable. Ensure the waterproof probe is used only in appropriate environments.
- Environmental Conditions: Store and operate the device within its specified temperature and humidity ranges.
11. Warranty and Support
For warranty information and technical support, please refer to the seller's policies or contact the retailer where you purchased the product. Keep your purchase receipt as proof of purchase.
An additional user manual in PDF format is available for download: View User Manual (PDF).
12. Frequently Asked Questions (FAQ)
- Q: Can I use this controller for both heating and cooling?
- A: Yes, by setting the P0 (start temperature) and P1 (stop temperature) appropriately, you can configure the controller for either heating or cooling applications. For heating, P0 should be lower than P1. For cooling, P0 should be higher than P1.
- Q: What type of sensor does it use?
- A: It uses an NTC10K L=1 meter waterproof probe.
- Q: Is the sensor replaceable?
- A: Yes, the sensor can be easily replaced using the 2P terminal.
- Q: What is the purpose of the P3 (Delay Start) setting?
- A: P3 is primarily used for compressor refrigeration to prevent frequent starts and stops, which can damage the compressor. It sets a delay in minutes before the output activates again after turning off.