1. Important Safety Instructions
Please read and understand these safety instructions before using or maintaining the equipment to ensure safe and proper operation.
- The tester uses a 9V battery for power supply.
- Do not place the equipment in environments with excessive dust, humidity, or high temperatures (over 40°C).
- Use only the specified battery type. Incorrect battery usage may damage the equipment.
- Do not disassemble the equipment. Maintenance should only be performed by professional personnel.
- The tester will automatically shut off if it is not used for 30 minutes.
- Remove batteries from the launcher and receiver if the equipment will not be used for a long time to prevent battery leakage.
- Never use the equipment to detect live power cords (e.g., 220V power supply circuits), as this may result in damage to the equipment and personal injury.
- Avoid operating communication lines during thunderstorms to prevent lightning strikes and ensure personal safety.
2. Product Overview
The NOYAFA NF-388 is a practical cable test and inspection instrument designed for technicians in the installation and maintenance of weak current systems, including telephone systems and computer networks. It offers comprehensive functions for wire hunting, wire sorting, and circuit status testing with high accuracy.
2.1. Main Functions
- Cable Continuity Check: Tests 5E, 6E, and Coaxial cables for open circuits, short circuits, cross circuits, and reverse connections.
- Cable Length Measurement: Measures network cable length up to 1000m and identifies the distance to open or short circuit faults with 98% accuracy.
- Cable Tracking/Hunting: Directly locates 5E, 6E, telephone, coaxial, USB, and metal cables.
- Port Flashing: Helps to easily find 5E/6E network cables connected to a Hub/Switch by flashing the port light.
- Polarity Testing: Measures DC voltage (0.5-60V).
- Memory and Storage: Stores calibration data for different cable types.
- Automatic Features: Time-delay shut-off and low battery alarm function.
- Remote Identification: Comes with 8 remote units for efficient testing of multiple cables.



3. Setup
3.1. Package Contents
The NF-388 package typically includes:
- 1 x NF-388 Emitter (Main Tester)
- 1 x NF-388-S Receiver
- 8 x NF-388-R Remote Units
- 1 x Earphone
- Cable Leads (for various connections)
- 1 x Instruction Manual (this document and a PDF version)

3.2. Battery Installation
The NF-388 Emitter and Receiver each require a 9V Alkaline battery (NEDA 1604/6F22 DC9V). Batteries are NOT INCLUDED in the package.
- Locate the battery compartment on the back of both the Emitter and Receiver units.
- Open the battery compartment cover.
- Insert a 9V battery, ensuring correct polarity.
- Close the battery compartment cover securely.

4. Operating Instructions
4.1. Product Structure and Interface
Familiarize yourself with the components and ports of the NF-388 Emitter, Receiver, and Remote Units.

Emitter (Main Tester)
- LCD Screen: Displays test results and menu options.
- Function Buttons: PAIR&L (Pair & Length), SCAN, ON/OFF, Up/Down arrows, Status.
- Ports: MAIN (RJ45), PORT FLASH (RJ45), BNC, RJ11 SCAN, USB SCAN, RJ45 SCAN, Power Input.
Receiver
- Probe: Used for cable tracing.
- Lamp: For illumination in dark environments.
- Earphone Jack: For use with earphones in noisy environments.
- VOL: Volume control for the speaker.
- PUSH TO TEST: Button to initiate scanning.
- Scan Button: Activates scanning function.
- Speaker: Emits tone for cable tracing.
Remote Units
- Compatible Connectors: RJ45, BNC.
- Used for remote end testing of cables.
4.2. Basic Operation and Menu Navigation
Upon powering on, the device performs a self-check and then displays the main menu. Use the Up/Down arrow buttons to navigate through the menu options and the PAIR&L button to select.
Main Menu Options:
- WireMap: For wiring diagram measurement and error location.
- Pair&Length: For measuring cable length and identifying fault distances.
- Coax/Tel: For coaxial and telephone cable testing.
- Port Flash: To locate network ports on a switch.
- Polar Test: To test polarity and DC voltage.
- Setup: For calibration and unit settings.
4.3. WireMap (Wiring Diagram Test)
This function checks for open circuits, short circuits, cross circuits, and reverse connections in RJ45, RJ11, and BNC cables.
- Select 'WireMap' from the main menu.
- Local Test Mode: Connect one end of the cable to the 'MAIN' port on the Emitter and the other end to the 'RJ45 SCAN' port on the Emitter. The screen will display the wiring status.
- Remote Test Mode: Connect one end of the cable to the 'MAIN' port on the Emitter and the other end to a Remote Unit. The screen will display the wiring status, indicating any faults.
Note: For NF-388, the 'G' (ground) cannot be displayed in remote test mode due to programming limitations. To test 'G', use local test mode.


4.4. Pair & Length Measurement
This function measures the length of RJ45 cables and identifies the distance to a fault.
- Select 'Pair&Length' from the main menu.
- Connect one end of the RJ45 cable to the Emitter's 'MAIN' port. No remote unit is needed for length measurement.
- The screen will display the length of each pair and the distance to any detected faults (open or short).

4.4.1. Length Calibration
For accurate length measurements, especially for different cable types, calibration is recommended.
- Go to 'Setup' from the main menu and select 'Calibration'.
- Connect a known length of cable (greater than 10m) to the 'MAIN' port.
- Confirm the measurement. Use the +/- buttons to adjust the displayed length to match the known length of your calibration cable.
- Press PAIR&L to save the calibration factor.
4.5. Coax/Tel Cable Test
This function tests the continuity of coaxial and telephone cables.
- Select 'Coax/Tel' from the main menu.
- Connect the coaxial or telephone cable to the appropriate ports on the Emitter.
- The screen will display 'PASS', 'OPEN', or 'SHORT' indicating the cable status.
Note: Never connect a charged telephone cable to the RJ45 port to avoid damaging the tester.
4.6. Port Flash (Locating Network Port)
This feature helps identify the physical port on a network switch or hub to which a specific cable is connected.
- Select 'Port Flash' from the main menu.
- Connect one end of the network cable to the 'PORT FLASH' port on the Emitter.
- Connect the other end of the cable to a port on the network switch/hub.
- Observe the lights on the switch. The port connected to the tester will flash at a lower frequency than other active ports, indicating it is the target port.

4.7. Polarity Testing
This function measures DC voltage and identifies polarity.
- Select 'Polar Test' from the main menu.
- Connect the standard alligator clips to the RJ11/SCAN port.
- Connect the clips to the power source you wish to test.
- The screen will display the voltage and polarity (e.g., 'Red (4P):+', 'Black (3P):-').

4.8. Cable Tracking/Hunting (AF Hunting Function)
This function helps locate a specific cable among a bundle of cables.
- Press the 'PUSH' button on the Receiver. The hunting indicator light (SCAN) will flash, indicating that the audio frequency transmission of the Emitter is normal.
- Connect the cable to be traced to the Emitter's RJ45 SCAN port (or corresponding RJ11/BNC/USB port).
- Hold the Receiver's probe near the cables.
- When the probe is near the target wire, a 'beep, beep, beep' sound will be emitted, and the signal indicator light will be on. The loudest beep and brightest indicator signify the correct cable.
- Adjust the volume switch on the Receiver to control the sound level.
- Use the built-in lamp for working in dark environments.
- Use earphones to avoid external interference in noisy environments.
Note: The cable tracking function does not measure cable length or wire faults.


4.9. Video Demonstration
5. Maintenance
To ensure the longevity and proper functioning of your NF-388 tester, follow these maintenance guidelines:
- Keep the device clean and free from dust. Use a soft, dry cloth for cleaning.
- Avoid exposing the device to extreme temperatures or high humidity.
- If the device will not be used for an extended period, remove the batteries from both the Emitter and Receiver to prevent potential leakage and damage.
- Do not attempt to open or repair the device yourself. Refer to qualified service personnel for any repairs.
6. Troubleshooting
Here are some common issues and their solutions:
- "Wire Map FAIL" displayed: Indicates an open circuit, short circuit, or cross-over in the cable. Check cable connections and the cable itself for damage.
- "NO ADAPTER" displayed: The cable is not properly connected to the far-end matcher (Remote Unit) or the local port on the Emitter. Ensure secure connections.
- "CABLE TO SHORT!" displayed during length calibration: The calibration cable used is too short. Use a cable longer than 10 meters for calibration.
- No power or device not turning on: Check if the 9V batteries are correctly installed and have sufficient charge. Replace batteries if necessary.
- No tone or weak tone during cable tracking: Ensure the Receiver's volume is adjusted correctly. Check battery levels. Ensure the cable is properly connected to the Emitter's SCAN port.
7. Specifications
| Feature | Specification |
|---|---|
| Brand Name | NOYAFA |
| Model Number | NF-388 |
| Type | Multifunction Network Tester |
| Certification | CE |
| Ports | RJ45, RJ11, BNC, USB |
| Tracking Type | RJ45, RJ11, BNC, USB, Metal Cable |
| Wiremapping Type | RJ45, RJ11 cable |
| Test Length | RJ45 Cable (up to 1000m) |
| Length Testing Accuracy | 97% |
| Remote Units | 8 pcs |
| Power | 9V Alkaline battery (NOT INCLUDED) |
| LCD Screen | 53x25 mm, with backlight |
| Tone Frequency | 225kHz |
| Max. Transmission Distance | 2 km |
| Max. Cable Map Distance | 1 km |
| Max. Working Current | Less than 70mA |
| Voltage Protection | AC 60V/DC 42V |
| Auto Shut-off | After 30 minutes of inactivity |
| Emitter Dimension (LxWxD) | 185x80x32 mm |
| Receiver Dimension (LxWxD) | 218x46x29 mm |
| Remote Unit Dimension (LxWxD) | 107x30x24 mm |
| Operating Temperature | -10°C to +60°C |


8. User Tips
- Always ensure you have a fresh 9V battery available before starting any testing, as the device does not include them.
- When using the Port Flash function, observe the switch lights carefully. The target port will flash at a noticeably slower rate.
- For accurate cable length measurements, perform a calibration using a cable of known length (over 10m) first.
- If working in a noisy environment, utilize the earphone jack on the receiver to better hear the tracing tone.
9. Warranty and Support