Mindray BS200 BS200E BS220 BS330 BS350

Rate this product
Contents

Mindray Biochemical Analyzer Liquid System Preventive Kit (FRU)

Instruction Manual

1. Introduction

This instruction manual provides essential information for the proper use and maintenance of the Mindray Liquid System Preventive Kit (FRU). This kit is designed to facilitate routine preventive maintenance of the liquid systems within compatible Mindray Biochemical Analyzers, ensuring their continued accuracy, reliability, and optimal performance. Adherence to these instructions will help extend the lifespan of your analyzer's liquid handling components and prevent potential issues.

2. Product Overview

The Liquid System Preventive Kit (FRU) contains a collection of essential components, primarily various types of tubing and connectors, required for the routine replacement of parts within the liquid handling system of Mindray Biochemical Analyzers. These components are critical for the precise aspiration, dispensing, and waste management of reagents and samples.

2.1 Kit Contents

The kit typically includes, but is not limited to, the following types of components:

  • Clear flexible tubing of various diameters and lengths.
  • White opaque tubing, often used for specific fluid paths.
  • Assorted connectors and fittings for secure tubing connections.
  • Cable ties for organizing and securing tubing runs.
Contents of the Liquid System Preventive Kit, showing various clear and white tubing, connectors, and cable ties, individually packaged.
Figure 1: Contents of the Liquid System Preventive Kit, showing various clear and white tubing, connectors, and cable ties, individually packaged.
The Liquid System Preventive Kit components neatly packed inside a cardboard box.
Figure 2: The Liquid System Preventive Kit components neatly packed inside a cardboard box.
Product label on the kit box, indicating 'Mindray', 'BS-220', 'Liquid System Preventive Kit (FRU)', and Part Number '115-020687-00'.
Figure 3: Product label on the kit box, indicating 'Mindray', 'BS-220', 'Liquid System Preventive Kit (FRU)', and Part Number '115-020687-00'.
Play video
Watch video online
Video 1: Overview of the various tubing and connector components included in the preventive maintenance kit.

3. Setup and Installation

This kit is intended for the replacement of existing liquid system components. Installation should only be performed by trained personnel familiar with the specific Mindray Biochemical Analyzer model.

3.1 Safety Precautions

  • Always power off and unplug the analyzer before beginning any maintenance.
  • Wear appropriate personal protective equipment (PPE), including gloves and eye protection.
  • Refer to the main service manual of your specific Mindray Biochemical Analyzer model for detailed safety procedures and component replacement instructions.
  • Ensure proper disposal of old components according to local regulations.

3.2 General Installation Guidelines

  1. Identify Components: Carefully match the new components from the kit with the parts to be replaced in the analyzer's liquid system. Each bag in the kit may contain a part number for identification.
  2. Disconnection: Gently disconnect the old tubing and connectors, noting their exact routing and connection points. It is recommended to take photos before disassembly for reference.
  3. Cleaning: Clean any accessible areas around the connection points to prevent contamination.
  4. Installation: Install the new tubing and connectors, ensuring all connections are secure and free from kinks or leaks. Use the provided cable ties to replicate the original tubing organization.
  5. Verification: After installation, visually inspect all connections.
  6. Testing: Power on the analyzer and perform necessary system checks and calibration procedures as outlined in your analyzer's service manual to confirm proper function of the liquid system.

4. Operating the Liquid System (Maintenance Context)

This kit does not involve operating the analyzer itself, but rather maintaining its liquid system. Once the components from this kit are installed, the analyzer's liquid system should function as per its original specifications. Always refer to your specific Mindray Biochemical Analyzer's user manual for operational procedures.

5. Maintenance

This kit is a maintenance kit. Its purpose is to provide the necessary parts for scheduled preventive maintenance of your Mindray Biochemical Analyzer's liquid system. Regular replacement of these components is crucial for:

  • Preventing leaks and blockages.
  • Maintaining accurate fluid delivery and aspiration.
  • Ensuring consistent analytical results.
  • Extending the overall service life of the analyzer.

Refer to the preventive maintenance schedule provided in your specific Mindray Biochemical Analyzer's service manual for recommended replacement intervals for liquid system components.

6. Troubleshooting

If issues arise with the liquid system after component replacement, consider the following general troubleshooting steps:

  • Leaks: Re-check all connections for tightness. Ensure O-rings or seals are properly seated and not damaged.
  • Blockages/Poor Flow: Verify that tubing is not kinked or pinched. Ensure connectors are fully open and not obstructed.
  • Incorrect Fluid Volumes: This could indicate issues with pump calibration, air bubbles in the system, or partially blocked tubing. Perform system priming and calibration as per the analyzer's manual.
  • Component Mismatch: Double-check that the correct components from the kit were installed in the appropriate locations.

For persistent or complex issues, consult the detailed troubleshooting section of your Mindray Biochemical Analyzer's service manual or contact qualified service personnel.

7. Specifications

FeatureDetail
Product NameLiquid System Preventive Kit (FRU)
Part Number115-020687-00
CompatibilityMindray Biochemical Analyzers BS200, BS200E, BS220, BS330, BS350
Kit ContentsVarious clear and white tubing, connectors, cable ties
Package Dimensions (L x W x H)60 cm x 45 cm x 32 cm
Package Weight2.0 kg
OriginMainland China

8. User Tips

  • Scheduled Maintenance: Adhere strictly to the preventive maintenance schedule outlined in your analyzer's main manual. Proactive replacement of liquid system components can prevent costly downtime and ensure consistent results.
  • Component Identification: Before installation, carefully verify part numbers on the new components against the old ones or the analyzer's service manual to ensure correct fit and function.
  • Documentation: Keep a record of when the kit components were installed for future reference and to track maintenance cycles.

9. Warranty & Support

This Liquid System Preventive Kit (FRU) is supplied by IVDMedical Accessories Store. For any questions regarding the product, its compatibility, or installation, please contact the seller directly. For detailed service and support related to your Mindray Biochemical Analyzer, please refer to your analyzer's official documentation or contact Mindray customer service.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?