SRNE HF4850S80-H

Contents

SRNE 5000W Hybrid Solar Inverter User Manual

Model: HF4850S80-H

1. Introduction

The SRNE HF series is a new hybrid solar charge inverter, integrating solar energy storage, mains charging energy storage, and AC sine wave output. Utilizing DSP control and an advanced control algorithm, it offers high response speed, reliability, and industrial standard performance.

Key features include:

  • Full digital voltage and current double closed-loop control, advanced SPWM technology, output of pure sine wave.
  • Two output modes: mains bypass and inverter output; uninterrupted power supply.
  • Four charging modes: Only Solar, Utility Priority, PV Priority, and Utility & Solar hybrid charging.
  • Advanced MPPT technology with an efficiency of 99.9%.
  • LCD screen and 3 LED indicators for dynamic display of system data and operating status.
  • Manual ON/OFF switch controlling AC output.
  • Power saving mode to reduce empty load loss.
  • Intelligent variable speed fan for efficient heat dissipation and extended system life.
  • Lithium battery activation by PV solar or mains, allowing access of lead-acid battery and lithium battery.
  • Comprehensive protections: short circuit, over voltage, under voltage, overload, reverse protection, etc.

2. Package Contents

Upon unpacking, please ensure all items are present and undamaged:

  • All-in-one Solar Charge Inverter (x1)
  • User Manual (x1)
  • M5 Screws (x4)
  • Terminal Blocks (x2)
Package contents of the SRNE Hybrid Solar Inverter, including the inverter unit, user manual, screws, and terminal blocks, with dimensions of the packaging box.
Figure 2.1: Package contents and dimensions.

3. Setup and Installation

Important Safety Notice: This product is for indoor use only. It is forbidden to use it outdoors.

3.1 Product Overview and Connections

Familiarize yourself with the inverter's ports and controls:

Diagram showing the SRNE Hybrid Solar Inverter's LCD screen, buttons (SET, UP, DOWN, ENT), LED indicators (AC/INV, CHARGE, FAULT), and rear panel connections including Overload protector, ON/OFF rocker switch, AC input/output ports, Grounding screw, RS485, USB, Dry contact port, Cooling fans, Battery ports, PV port, Touch key, and Indicator light.
Figure 3.1: Inverter appearance and port description.

Port Descriptions:

  1. Overload protector
  2. ON/OFF rocker switch
  3. AC input port
  4. AC output port
  5. Grounding screw hold
  6. RS485-2 communication port
  7. USB communication port
  8. RS485-1 communication port
  9. Dry contact port
  10. Cooling fan
  11. Battery port
  12. PV port
  13. Touch the key lightly
  14. Indicator light
  15. LCD screen

3.2 Product Connection Diagram

The inverter connects to PV panels, an external battery bank, and household loads. It can also integrate with a generator or utility power.

Product connection diagram showing PV Panel, Generator or Utility, External Battery packs, and Household loads (refrigerator, light bulb, computer, fan, TV) connected to the SRNE inverter. Note: The solar panels must be connected in series! The max input current is 40A!
Figure 3.2: General product connection diagram. Note: Solar panels must be connected in series. Maximum input current is 40A.

The inverter is compatible with various 48V battery types, including Lead-Acid (Sealed/AGM/Flooded/GEL) and Lithium batteries. A 48V battery is necessary for operation.

Diagram illustrating compatibility with multiple 48V battery types: Lead-Acid (Sealed/AGM/Flooded/GEL) and Lithium. A note states that a 48V battery is necessary and setting 09-21 is only available when the corresponding battery type is selected.
Figure 3.3: Battery compatibility and selection note.

3.3 Wi-Fi Module Installation and Setup

The inverter supports an optional Wi-Fi module for remote monitoring and control.

Wi-Fi PlugPro Quick Installation Guideline showing steps for installation, wireless router connection, account creation, and datalogger addition. Includes QR codes for SmartESS app (iOS/Android) and LED indicator descriptions (PWR, COM, NET, ERR).
Figure 3.4: Wi-Fi PlugPro Quick Installation Guideline.

Wi-Fi PlugPro Quick Installation Guideline (MS-W-09):

  1. Installation: Connect the 4PIN aviation plug of the Wi-Fi PlugPro to the power cable aviation side and tighten it. Connect the other side of the power cable to the inverter. Check the working status of the LED indicator (after step 2.3, when 4 LED indicators keep on, showing the normal working status).
  2. Wireless Router Connection:
    1. Open the APP, tap the Wi-Fi Config button to enter this page.
    2. Then tap the Network Setting button.
  3. Network Setting: According to the prompts, type in the information to finish the network setting. After the Wi-Fi PlugPro is restarted, reconnect the Wi-Fi when prompted by step 2.1.
  4. Create Account and Datalogger:
    1. Create Account: Open the APP, tap the Register button. According to the prompt information, complete creating an account.
    2. Add Datalogger: Login the account and click the list button on the bottom of the home page. Tap the "+" button on the top-right corner of the list page. Scan the datalogger PN on the Wi-Fi PlugPro, or input it manually. According to the prompts, type in the information to finish add datalogger.

LED Indicators:

  • PWR: Power Status LED indicator
  • COM: Communication Status LED indicator
  • NET: Network Status LED indicator
  • ERR: Error Status LED indicator

4. Operating Modes

The inverter offers flexible charging and output modes to suit various energy management needs.

4.1 Charging Modes

You can select from four distinct charging modes:

  • Solar Charging ONLY: Prioritizes solar power for battery charging.
  • Electricity Utility Priority: Prioritizes utility power for battery charging.
  • Solar Priority: Prioritizes solar power for both charging and load supply.
  • Hybrid Charging: Combines solar and utility power for optimal charging.

4.2 Load Output Modes

Three load output modes are available:

  • PV Priority: Solar power is prioritized to supply the load.
  • Utility Priority: Utility power is prioritized to supply the load.
  • Inverter Mode: The inverter supplies power from the battery to the load.
Diagram illustrating four charging modes (Solar Charging ONLY, Electricity Utility Priority, Solar Priority, Hybrid Charging) and three load output modes (PV Priority, Utility Priority, Inverter Mode) for the SRNE Hybrid Solar Inverter.
Figure 4.1: Charging and Load Output Modes.

4.3 Product Overview Video

Video 4.1: A visual overview of the SRNE 5000W Hybrid Solar Inverter, showcasing its design and various connection points.

5. Maintenance

To ensure optimal performance and longevity of your SRNE Hybrid Solar Inverter, regular maintenance is recommended:

  • Cleaning: Periodically clean the exterior of the inverter with a dry, soft cloth. Ensure ventilation openings and cooling fans are free from dust and debris. The intelligent variable speed fan helps dissipate heat efficiently, but external dust can hinder its performance.
  • Connections: Regularly check all electrical connections (PV, battery, AC input/output) to ensure they are secure and free from corrosion. Loose connections can lead to poor performance or safety hazards.
  • Environment: Ensure the inverter is operated within its specified temperature and humidity ranges. Avoid exposing it to direct sunlight, moisture, or corrosive substances.
  • Firmware Updates: If available, check for and apply any firmware updates to ensure the inverter operates with the latest features and bug fixes. This can often be done via the Wi-Fi module and SmartESS app.

6. Troubleshooting

This section provides general guidance for common issues. For complex problems, please contact customer support.

  • No Power Output: Check all input connections (PV, AC input, battery). Ensure the ON/OFF switch is in the 'ON' position. Verify battery voltage is within the operating range. Check for any fault indicators on the LCD or LEDs.
  • Charging Issues: Confirm PV panels are receiving adequate sunlight and are correctly connected. Check AC input if using utility charging. Verify battery type settings are correct.
  • Overload Protection: If an overload fault occurs, reduce the connected load. The inverter has overload protection that will shut down the output.
  • Wi-Fi Connection Problems: Ensure the Wi-Fi PlugPro is correctly installed and its LEDs indicate normal operation. Check your router settings and ensure the inverter is within range. Refer to the Wi-Fi PlugPro Quick Installation Guideline (Figure 3.4).

If the fault persists, record any error codes or indicator patterns and contact customer support for further assistance.

7. Specifications

Detailed technical specifications for the SRNE HF4850S80-H Hybrid Solar Inverter:

CategoryParameterValue (HF4850S80-H)
GeneralModel NumberHF4850S80-H
TypeDC/AC Inverters
Size426mm*322mm*126mm
Weight12KG
IP GradeIP 20
Operating Temperature Range-15°C to 55°C
AC ModeRated input voltage200/230VAC
Input voltage range(170Vac~280Vac) ±2%; (90Vac-280Vac) ±2%
Frequency50Hz/60Hz (auto-sensing)
Frequency Range47±0.3Hz-55±0.3Hz (50Hz)/57±0.3Hz-65±0.3Hz (60Hz)
Overload/Short circuit protectionBreaker
Maximum bypass overload current40A
Inverting ModeOutput voltage waveformPure sine wave
Rated output power (VA)5000VA
Rated output power (W)5000W
Peak power10000VA
Output AC Voltage230Vac (200/208/220/240Vac settable)
Output Frequency50Hz/60Hz
Efficiency>95%
Battery & AC ChargeRated Battery Voltage48V (minimum start-up voltage 44V)
Battery typeLead Acid or Lithium
Maximum Charging Current (AC)40A
Charge voltage range40-60Vdc
Overload / Short circuit ProtectionBreaker
Solar Charge (MPPT)Output CurrentMPPT 80A
Recommended PV Max500Vdc
PV operation voltage range120-500Vdc
MPPT voltage range120-450Vdc
ProtectionWiring ProtectionReverse Polarity
Charge short-circuit protectionBlown fuse
CommunicationCommunication interfaceUSB/RS485 (WiFi/GPRS)/dry node control

8. User Tips

Based on common user inquiries and experiences, consider the following tips:

  • Battery Capacity Matching: The battery capacity of the correct matching system is crucial. It should be determined according to the specific usage requirements of your load and application scenarios. Incorrect matching can lead to insufficient battery capacity or excessive waste of power generation. Always refer to the manual's recommendations or consult with a qualified professional.
  • Indoor Use Only: Adhere strictly to the warning that this product is for indoor use only. Outdoor exposure can damage the unit and void warranty.
  • Wi-Fi Module: If your model includes the Wi-Fi module, ensure proper installation and configuration using the SmartESS app for remote monitoring and control. This can greatly enhance convenience in managing your solar system.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Details regarding warranty duration and service centers may vary by region. It is recommended to retain your purchase receipt for warranty claims.

For any questions regarding the product's functionality or troubleshooting, please refer to this manual or reach out to the official support channels.

© 2023 SRNE. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.