INKBIRD ITH-20R

Rate this product if you’ve used it
Contents

INKBIRD ITH-20R Digital Thermometer Hygrometer Instruction Manual

Model: ITH-20R

1. Introduction

Thank you for choosing the INKBIRD ITH-20R Digital Thermometer Hygrometer. This device provides accurate and reliable monitoring of temperature and humidity, both indoors and outdoors, with wireless transmission capabilities. It is designed for various applications including baby rooms, greenhouses, offices, warehouses, and more. Please read this manual carefully before use to ensure proper operation and to maximize the product's lifespan.

INKBIRD ITH-20R main display unit with three wireless transmitters

Figure 1: INKBIRD ITH-20R Main Display Unit and Transmitters

2. Package Contents

The INKBIRD ITH-20R comes in various configurations. Please check your package against the list below:

  • Receiver (ITH-20R-I): 1 unit
  • Transmitter(s) (ITH-20-O): 1, 2, or 3 units, depending on the purchased variant.
  • Screwdriver: 1 or 2 units (depending on the number of transmitters)
  • External Probe(s): 1, 2, or 3 units (matching the number of transmitters)
  • User Manual: 1 or 2 units
  • Warranty Card: 1 or 2 units
Product packing list showing receiver, three transmitters, screwdriver, three probes, packing box, instruction manual, and warranty card

Figure 2: Example Package Contents (3 Transmitters Version)

3. Product Overview

3.1 Receiver (ITH-20R-I)

The receiver unit features a large LCD display showing indoor and outdoor temperature and humidity readings. It also includes buttons for mode selection and settings.

Back view of the INKBIRD ITH-20R receiver showing CH/R, °C/°F, and MAX/MIN CLEAR buttons, and battery compartment

Figure 3: Receiver Back Panel with Buttons

  • CH/R Button: Used to switch between different transmitter channels (CH1, CH2, CH3) or to re-register transmitters.
  • °C/°F Button: Toggles the temperature display between Celsius and Fahrenheit.
  • MAX/MIN CLEAR Button: Displays the maximum and minimum recorded temperature/humidity. Press and hold to clear the recorded values.

3.2 Transmitter (ITH-20-O)

The transmitter units wirelessly send temperature and humidity data to the receiver. Each transmitter can be placed in a different location to monitor specific areas.

Front view of a single INKBIRD wireless transmitter unit

Figure 4: Wireless Transmitter Unit

4. Specifications

Image showing detailed product parameters including brand, model, transmission distance, power supply, dimensions, and measurement ranges

Figure 5: Detailed Product Parameters

FeatureDescription
Brand NameINKBIRD
Model NumberITH-20R
TheoryTemperature Controller
Display TypeDIGITAL (LCD)
Power TypeAAA Battery (2 x AAA Batteries for each unit)
Battery IncludedYes
CertificationCE, FCC
Is Smart DeviceYes
UseHousehold
Display Size1.9 Inches & Under
Transmission Frequency433MHz
Transmission Distance≈300 Feet (up to 500 ft in open areas)
Maximum Available Transmitters3
Receiver Dimensions75*64*21mm
Transmitter Dimensions75*64*21mm
Receiver Temp. Range-20~60°C (-4~140°F)
Receiver Humidity Range10% ~ 95%
Transmitter Temp. Range-40~70°C (-40~158°F)
Transmitter Humidity Range10% ~ 95%
Probe Temp. Range-50~125°C (-58~257°F)
Temperature Display Accuracy0.1°C/F
Temperature Measurement Accuracy±1°C
Humidity Measurement Accuracy±5%
Humidity Display Accuracy1%
Sampling Time10 Seconds
Out of Range Display“HH.L” or “LL.L”
Warranty12 Months
Diagram showing the dimensions of the receiver, transmitter, and external probe

Figure 6: Product Dimensions

5. Setup

5.1 Battery Installation

Both the receiver and each transmitter require 2 AAA batteries. The batteries are included in the package.

  1. Open the battery compartment cover on the back of the receiver and each transmitter.
  2. Insert 2 AAA batteries into each unit, ensuring correct polarity (+/-).
  3. Close the battery compartment covers securely.

5.2 Initial Pairing and Placement

The units should automatically pair upon battery installation. If not, follow these steps:

  1. Place the receiver in your desired indoor location. It can stand on a flat surface or be wall-mounted using the hole on the back.
  2. Place the transmitter(s) in the area(s) you wish to monitor (e.g., baby room, greenhouse, outdoor). The outdoor unit is rainproof.
  3. The receiver will automatically cycle through the channels (CH1, CH2, CH3) displaying the data from each connected transmitter.

5.3 Connecting the External Probe

The external probe can be connected to any transmitter to measure liquid temperatures or temperatures in narrow/closed environments.

  1. Locate the jack on the side of the transmitter.
  2. Insert the external temperature probe's plug into the jack.
  3. The transmitter will now use the probe for temperature readings for its channel.
Play video
Watch video online

Video 1: Demonstrating External Probe Connection and Use

6. Operating Instructions

6.1 Reading the Display

The receiver's LCD displays the following information:

  • OUT: Outdoor temperature and humidity (from the currently displayed transmitter channel).
  • IN: Indoor temperature and humidity (measured by the receiver itself).
  • CH: Indicates the current transmitter channel being displayed (CH1, CH2, or CH3).
  • Battery Indicator: Shows the battery level for both the receiver and the active transmitter.

6.2 Switching Temperature Units (°C/°F)

Press the °C/°F button on the back of the receiver to switch the temperature display between Celsius and Fahrenheit.

6.3 Viewing and Clearing MAX/MIN Readings

Press the MAX/MIN CLEAR button on the back of the receiver to view the maximum and minimum temperature and humidity values recorded since the last reset.

  • Press once to display MAX values.
  • Press again to display MIN values.
  • Press a third time to return to current readings.
  • To clear the recorded MAX/MIN values, press and hold the MAX/MIN CLEAR button for approximately 3 seconds.

6.4 Switching Transmitter Channels

If you have multiple transmitters, press the CH/R button on the back of the receiver to cycle through the channels (CH1, CH2, CH3). The display will show the readings for the selected channel. The receiver will automatically cycle through all active channels every few seconds.

Image showing various application scenarios for the thermometer hygrometer, including baby room, cigar storage, greenhouse, office, warehouse, and guitar room

Figure 7: Diverse Application Scenarios

7. Maintenance

7.1 Battery Replacement

When the battery indicator on the receiver or transmitter shows low power, replace the AAA batteries promptly to ensure continuous and accurate readings. Refer to section 5.1 for battery installation instructions.

7.2 Cleaning

Wipe the units with a soft, damp cloth. Do not use abrasive cleaners or immerse the receiver in water. The outdoor transmitter unit is rainproof but should not be submerged.

7.3 Storage

If the device will not be used for an extended period, remove the batteries from both the receiver and transmitters to prevent leakage and damage.

8. Troubleshooting

  • No Display: Check if batteries are installed correctly and have sufficient power. Replace if necessary.
  • No Outdoor Reading: Ensure the transmitter is within the 300ft transmission range and there are no major obstructions (thick walls, large metal objects). Press the CH/R button to re-sync or check the transmitter's batteries.
  • Inaccurate Readings: Ensure units are not placed near heat sources, direct sunlight, or strong drafts. Allow units to stabilize for 15-30 minutes after initial setup or relocation.
  • “HH.L” or “LL.L” Display: This indicates that the temperature or humidity is out of the device's measurement range.
Diagram illustrating wireless data transmission from transmitters to the receiver across different rooms in a house

Figure 8: Wireless Transmission Diagram

9. User Tips

  • For optimal accuracy, place the receiver and transmitters away from direct sunlight, heating/cooling vents, and sources of moisture.
  • When using the external probe, ensure it is fully immersed in the liquid or placed securely in the environment you wish to monitor.
  • Consider using rechargeable AAA batteries for long-term cost savings and environmental benefits.

10. Warranty and Support

The INKBIRD ITH-20R Digital Thermometer Hygrometer comes with a 12-month warranty from the date of purchase. This warranty covers manufacturing defects and malfunctions under normal use.

For technical support, warranty claims, or any questions regarding your product, please contact INKBIRD customer service through the seller's platform or the official INKBIRD website. Please have your purchase details and product model number (ITH-20R) ready when contacting support.

© 2024 INKBIRD. All rights reserved.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?