1. Introduction
The INKBIRD ITC-310T-B is a sophisticated dual-relay outlet thermostat featuring a programmable timer function. This controller allows for precise temperature management across 12 distinct time periods, each with its own temperature setting. It is an ideal solution for maintaining stable temperatures in various applications, including beer and wine brewing fermentation, home brewing, aquariums, pet breeding, hatching, barbecue, boiler temperature control, geothermal systems, heating pump constant temperature cycles, strain culture fermentation, seed sprouting, electric heating, electric ovens, and general over-temperature protection and automatic temperature control systems for electrical equipment.

2. Package Contents
Upon opening your INKBIRD ITC-310T-B package, please verify that all the following items are included:
- 1 x ITC-310T-B Thermostat
- 1 x NTC Temperature Sensor (2m / 6.56ft length)
- 1 x User's Manual

3. Product Overview
Familiarize yourself with the components and controls of your ITC-310T-B Temperature Controller:

- 1. PV Display: Shows the current measured temperature (Process Value).
- 2. SV Display: Shows the set temperature value (Set Value).
- 3. HEATING Indicator: Illuminates when the heating output is active.
- 4. SET Button: Used to enter and confirm settings.
- 5. COOLING Indicator: Illuminates when the cooling output is active.
- 6. Up Arrow Button: Used to increase values or navigate menus.
- 7. Down Arrow Button: Used to decrease values or navigate menus.
- 8. Heating Outlet: Connect your heating device here.
- 9. Cooling Outlet: Connect your cooling device here.


4. Setup
- Connect the Sensor: Insert the NTC temperature sensor into the designated port on the controller. Ensure it is securely connected.
- Position the Sensor: Place the sensor in the environment where temperature needs to be controlled (e.g., fermenter, incubator, greenhouse). Ensure it is not directly exposed to heating or cooling elements to get an accurate reading.
- Connect Devices: Plug your heating device into the 'HEATING' outlet and your cooling device into the 'COOLING' outlet on the controller.
- Power On: Plug the ITC-310T-B controller's main power cord into a suitable electrical outlet. The display will light up, showing the current temperature (PV) and the set temperature (SV).
5. Operating Instructions
The ITC-310T-B offers versatile temperature control with its programmable timer and dual relay outputs.
5.1 Basic Temperature Setting
- Press the SET button once. The SV display will flash.
- Use the Up or Down arrow buttons to adjust the desired set temperature.
- Press SET again to confirm and exit.
5.2 Timer Function (12 Periods)
The controller allows you to set 12 different temperatures for 12 different periods of time. The timers activate once the setpoint temperature for that period is reached.
- Setting Periods: Refer to the detailed instructions in the included User's Manual for programming each of the 12 time stages and their corresponding temperatures.
- Control Modes: You can choose between single-cycle or continuous-cycle control modes. The time setting range is wide, from 1 to 999 (minutes/hours) or 1 to 90 (days). For infinite cycles, set the cycle count to '00'.
5.3 Temperature Unit Selection (°C/°F)
The unit of temperature display can be switched between Celsius (°C) and Fahrenheit (°F). Consult the User's Manual for specific steps on how to change this setting.
5.4 Alarms
The ITC-310T-B features alarms for over-temperature conditions and sensor errors, providing an audible alert to notify you of potential issues.
5.5 Compressor Delay & Temperature Calibration
Advanced settings such as compressor delay protection and temperature calibration are available to fine-tune the controller's performance. These settings are crucial for protecting connected equipment and ensuring accurate temperature readings. Please refer to the comprehensive User's Manual for detailed instructions on configuring these parameters.

6. Specifications
| Feature | Specification |
|---|---|
| Model Number | INKBIRD ITC-310T-B |
| Theory | Temperature Controller |
| Display Type | DIGITAL (PV and SV dual display) |
| Power Type | None (Plug-in device) |
| Certification | CE |
| Use | Household |
| Is Smart Device | No |
| Temperature Control Range | -50 to 120°C / -58 to 248°F |
| Temperature Resolution | 0.1°C / 0.1°F |
| Measuring Accuracy | ±1°C (-50 ~ 70°C) / ±1°F(-58 ~ 158°F) |
| Temperature Control Mode | On/Off Control, Heating and Cooling |
| Timing Accuracy | 24 hours ±1.7s |
| Timing Range | 1~999 (min/hour/day) |
| Periods of Time Max | 12 periods |
| Cycle Setting | 1-999 times cycle, or 00 infinite cycle |
| Control Output Current | Max. 10A |
| Input Power (US PLUG) | 110V-120VAC, 60Hz |
| Power (EU/UK/AU PLUG) | 220V-240V, 50Hz |
| Buzzer Alarm | High and Low Temperature Alarm |
| Sensor Type | NTC sensor (Included) |
| Sensor Length | 2m / 6.56ft |
| Input Power Cable Length | 1.5m (5ft) |
| Dimension | 135x54x40mm (5.3x2.1x1.6 inch) |
| Operating Ambient Temperature | -30~ 75°C / -22~ 167°F |
| Storage Condition Temperature | -20~ 60°C / -4~ 140°F |
| Humidity | 20~85% (No freeze or moisture condensation) |

7. Troubleshooting
If you encounter issues with your ITC-310T-B, consider the following common troubleshooting steps:
- No Power/Display: Ensure the controller is securely plugged into a working power outlet. Check the power source.
- Inaccurate Temperature Reading: Verify that the NTC sensor is correctly connected and positioned appropriately within the environment. Ensure the sensor tip is clean and free from debris.
- Heating/Cooling Device Not Activating: Check if the heating/cooling device is properly plugged into the correct outlet on the controller. Confirm that the set temperature and current temperature are within the range that should trigger the device (e.g., for heating, PV < SV; for cooling, PV > SV). Check the device itself to ensure it is functional.
- Alarm Sounds: An alarm indicates either an over-temperature/under-temperature condition or a sensor error. Check the temperature readings and the sensor connection. Refer to the manual for specific alarm codes if displayed.
- Settings Not Saving: Ensure you press the SET button to confirm any changes made to the settings.
For more detailed troubleshooting or persistent issues, please refer to the complete User's Manual or contact INKBIRD customer support.
8. User Tips
While specific user reviews or Q&A were not provided, here are some general tips for optimizing your experience with the INKBIRD ITC-310T-B Temperature Controller:
- Stable Sensor Placement: For best results, ensure your temperature sensor is placed in a location that accurately reflects the average temperature of your controlled environment, away from direct drafts or heat sources.
- Understand Delay Protection: Utilize the compressor delay setting to protect your cooling equipment from short cycling, which can extend its lifespan.
- Regular Calibration Check: Periodically verify the accuracy of your temperature readings against a known accurate thermometer and use the calibration function if necessary.
- Power Cycle for Reset: If the unit behaves unexpectedly, a simple power cycle (unplugging and replugging) can often resolve minor glitches.
9. Warranty and Support
The INKBIRD ITC-310T-B Temperature Controller comes with a 1-Year Warranty from the date of purchase. This warranty covers manufacturing defects and malfunctions under normal use. Please retain your proof of purchase for warranty claims.
For technical support, warranty service, or any questions regarding your product, please contact INKBIRD customer service through their official website or the contact information provided in your product packaging. When contacting support, please have your product model number (ITC-310T-B) and a detailed description of the issue ready.