1. Introduction
The SALORIE DMZ-I Electronic Electroacupuncture Muscle Stimulator is a multi-functional therapeutic instrument designed for body muscle stimulation and relaxation. It combines digital control low-frequency electronic pulse technology with traditional Chinese medicine acupuncture meridian theory. This device is fully functional, easy to operate, and designed for safe and effective use at home or in a clinical setting.
The instrument consists of three main parts: the host unit, the patch electrodes (or needle electrode clips), and an AC-DC converter.

2. Safety Precautions
Please read all safety warnings and instructions carefully before using this product. Failure to follow these instructions may result in injury or damage to the device.
- Not for use on patients with implanted medical devices such as pacemakers.
- Using electrodes close to the chest increases the risk of fibrillation.
- It cannot be used for pregnant women, patients with acute diseases, infectious diseases, malignant tumors, and heart diseases.
- Electroacupuncture should not be performed on scars, wounds, or inflamed skin.
- Do not use while driving or operating machinery.
- Do not use while bathing or sweating.
- When starting the treatment, ensure the two filiform needle electrode clips or skin electrodes at the output end do not touch each other to avoid short circuit and damage to the instrument.
- Disposable acupuncture needles or skin electrodes are recommended to avoid cross infection.
- Contact with metal objects is not allowed during use.
- Do not attach skin electrodes to the eyes, the front of the neck, and the heart.
- Do not use in flammable and explosive gas situations.
- Keep a certain distance from TVs, radios, and other electrical equipment to avoid possible electromagnetic interference.
- Acupuncture needle treatment should be used by a professional doctor (acupuncture needles are not part of this product). When the acupuncture needles are bent and deformed, the surface is oxidized, rusted, or stained, it cannot be applied.
- When used for measurement of load resistance exceeding ±10%, the deviation of pulse repetition frequency and degree value, including any DC component, during pulse duration is not more than 30%.
- The influence of the power supply voltage fluctuation ±10% on the output amplitude, pulse duration or pulse repetition frequency of the instrument is not more than ±10%.

3. Product Overview and Components
The DMZ-I features six independent output channels, allowing for simultaneous treatment of up to 12 acupoints. It offers dual power supply modes for convenience.
Core Functions:
- Six outputs
- Dual power supply mode
- 3 waveforms (Continuous, Intermittent, Sparse and dense)
- Adjustable pulse width
- Adjustable intensity frequency
- Digital timing

Package Contents:
- 1x Main Engine (DMZ-I)
- 6x Electrode Pads
- 6x Electrode Wires
- 6x Metal Needle Clips
- 12x Metal Electroacupuncture Clamps
- 1x Adapter (USB)
- 1x User Manual

4. Specifications
| Parameter | Value |
|---|---|
| Product Name | Electronic Acupuncture Therapeutic Instrument DMZ-I |
| Dimensions (L×W×H) | 240 × 177 × 64 mm |
| Weight | 1.1 kg |
| Output Voltage (Max) | 500V (Operating Load 250Ω) |
| Input Power | DC 9V (0.8VA); AC/DC converter (5VA) |
| Max Output Current (Effective Value) | 10mA |
| Rated Load Impedance (Patch Electrode) | 500Ω |
| Rated Load Impedance (Electrode Clamp) | 250Ω |
| Power Supply | USB adapter or 6x C batteries (not included) |
| Voltage Compatibility | 100-240V (Universal Voltage) |
| Application Area | Body |
5. Setup and Assembly
- Power Supply: The device can be powered by either the included USB adapter or 6 C-type batteries (not included).
- Using USB Adapter: Connect the USB adapter to the power input port on the side of the main unit and plug it into a suitable power outlet (100-240V compatible).
- Using Batteries: Open the battery compartment on the bottom of the device and insert 6 C-type batteries, ensuring correct polarity.

The device supports both power cord and battery operation. - Connecting Electrodes:
- Connect the electrode wires to the output channels (CH-1 to CH-6) on the front of the main unit.
- Attach the electrode pads or metal needle clips to the other end of the electrode wires.
- Ensure all connections are secure.

Connecting electrode wires and pads to the device outputs. - Applying Electrodes: Apply the skin-friendly hydrogel electrode pads to the desired areas of the body. Ensure the skin is clean and dry for optimal adhesion and conductivity. If using needle clips, ensure they are properly attached to acupuncture needles (not included) as directed by a professional.
6. Operation
The DMZ-I features an intuitive control panel with an LCD display for easy operation.

- Power On/Off: Press the 'Power' button to turn the device on or off.
- Select Waveform: Choose from three available waveforms (F1 Continuous wave, F2 Sparse and dense wave, F3 Intermittent wave) using the 'Mode' button or corresponding selectors.
- Adjust Frequency: Use the 'Freq' controls (F1 Freq, F2 Freq) to set the desired frequency between 5-99Hz.
- Adjust Pulse Width: Use the 'Pwm' controls to set the pulse width between 30-200µs.
- Set Treatment Time: Use the 'Time' controls to set the duration of your treatment session. The device features digital timing for safety and convenience, preventing overuse.

Digital timing function for safe use. - Adjust Intensity: For each channel (CH-1 to CH-6), use the individual rotary knobs to adjust the strength of the output. Start with the lowest setting and gradually increase to a comfortable level. The force required by each output route can be quickly adjusted.

Strength adjustment and waveform selection controls. - Start Treatment: Once all settings are configured and electrodes are applied, ensure the intensity knobs are at their minimum before starting. Gradually increase intensity as needed.
The device is designed to be easy to use and widely applicable for various body massage and stimulation needs.
7. Maintenance
- Cleaning: Wipe the main unit with a soft, dry cloth. Do not use abrasive cleaners or immerse the device in water.
- Electrode Pads: Replace electrode pads when they lose their adhesiveness or become dirty. Skin-friendly hydrogel patches are designed for ease of use and comfort.
- Storage: Store the device and accessories in a cool, dry place away from direct sunlight and extreme temperatures.
- Battery Replacement: If using batteries, replace all 6 C-type batteries when the power indicator shows low battery. Remove batteries if the device will not be used for an extended period.
8. Troubleshooting
- Device not turning on: Check if the USB adapter is properly connected and plugged into a working outlet, or if the batteries are correctly inserted and not depleted.
- No sensation from electrodes: Ensure electrode wires are securely connected to both the device and the pads/clips. Verify that the electrode pads are making good contact with the skin. Increase the intensity gradually.
- Weak or inconsistent sensation: Replace old or worn-out electrode pads. Check for any damage to the electrode wires.
- Display not working: Try turning the device off and on again. If the issue persists, ensure power supply is stable.
9. User Tips
- Portability: The compact size of the DMZ-I makes it convenient for use at home and during travel.
- Electrode Adhesion: For best results and comfort, ensure your skin is clean and dry before applying electrode pads. Additional pads can be purchased from the seller if needed.
- Voltage Compatibility: The device is designed for universal voltage (100-240V), making it suitable for use in various regions.
- Manual Language: If you require the user manual in a language other than English, please contact the seller for assistance.
10. Support
For any questions, technical support, or to inquire about additional accessories like electrode pads or alternative language manuals, please contact the SALORIE Global Dropshipping Store directly through your purchase platform.