A-BF A-BF Lab Variable DC Power Supply

Contents

A-BF Lab Variable DC Power Supply

Instruction Manual

Models: SS-3010MF, SS-3010MP, SS-305MF, SS-305MP, SS-4020HP, SS-8010HP, SS-1605HP

1. Introduction

The A-BF Lab Variable DC Power Supply is a highly efficient, low-ripple, and compact power source designed for various applications requiring stable and precise DC power. It features a four-digit display for simultaneous voltage, current, and power readings, along with comprehensive protection functions including Over Voltage Protection (OVP) and Over Current Protection (OCP). This manual provides essential information for the safe and effective operation of your device.

Package Contents

  • 1 x DC Power Supply Unit
  • 1 x Power Cable (specific to region: EU, UK, AU, US)
  • 1 x Test Line (alligator clips)
  • 1 x Product Manual & Certificate

Note: SS-3010MF/3010MP units shipped from Russia may not include the USB interface.

Package contents of the A-BF DC Power Supply including the unit, test leads, power cord, manual, and certificate.

Figure 1: Included Package Items

2. Safety Information

  • Always connect the power supply to a grounded outlet.
  • Do not operate the device in wet or damp conditions.
  • Ensure proper ventilation; do not block the cooling fan or vents.
  • Do not open the casing unless you are a qualified technician. High voltage is present inside.
  • Verify the input voltage setting matches your local power supply (110V or 220V).
  • Disconnect power before making or changing connections to the output terminals.
  • Use appropriate test leads and ensure they are in good condition.

3. Product Overview

The A-BF DC Power Supply is designed for precision and ease of use, featuring a clear digital display and intuitive controls.

Key Features

  • Complete operating protection functions (OVP, OCP)
  • High efficiency, low ripple, compact size, light weight
  • Double display for voltage, current, and power with high precision (four-digit display)
  • Voltage stabilization and current limiting capabilities
  • Dual voltage input for convenient choice (110V/220V)
  • Temperature-controlled fan for efficient heat dissipation and low noise
  • Dual potentiometers for precise adjustment of voltage and current
  • Quick Charge USB interface (5V/2A) on some models

Front Panel (MF Series)

Front and rear panel diagram of the A-BF MF series DC power supply, labeling display, controls, and ports.

Figure 2: MF Series Front and Rear Panel Layout

  • Voltage Display: Shows output voltage.
  • Current Display: Shows output current.
  • Power Display: Shows output power.
  • C.V. Indicator: Lights up when in Constant Voltage mode.
  • C.C. Indicator: Lights up when in Constant Current mode.
  • Key Lock Display: Indicates if controls are locked.
  • ON/OFF Button: Toggles power output.
  • Voltage Regulation Knob: Adjusts output voltage.
  • Current Regulation Knob: Adjusts output current.
  • USB Interface (5V/2A): For quick charging devices.
  • Output Negative (-): Black terminal for negative connection.
  • Output Positive (+): Red terminal for positive connection.

Front Panel (MP Series)

Front and rear panel diagram of the A-BF MP series DC power supply, labeling display, controls, and ports including memory buttons.

Figure 3: MP Series Front and Rear Panel Layout

  • M1-M3 Store/Recall Buttons: For saving and recalling preset voltage/current settings.
  • OCP Setting Button: For Over Current Protection settings.
  • OVP Setting Button: For Over Voltage Protection settings.
  • Other controls are similar to the MF series.

Rear Panel (MF/MP Series)

  • Power Switch Button: Main power switch for the unit.
  • Cooling Fan: Provides air-cooled heat dissipation.
  • AC Power Input Socket: Connects to the main power cable.
  • Fuse Holder: Contains the protective fuse.

4. Setup

  1. Unpacking: Carefully remove the power supply and all accessories from the packaging. Inspect for any signs of damage.
  2. Power Connection:
    • Ensure the power supply's input voltage matches your local power grid (110V or 220V). The unit supports dual voltage input.
    • Connect the provided power cable to the AC Power Input Socket on the rear panel and then to a grounded wall outlet.
    Diagram showing different plug types: EU, UK, AU, US.

    Figure 4: Available Plug Types

  3. Initial Power On: Flip the main power switch on the rear panel to the 'ON' position. Then, press the ON/OFF button on the front panel to activate the output.
  4. Output Connections: Before connecting any load, ensure the power output is OFF. Connect your load to the red (+) and black (-) output terminals using the provided test leads or other suitable cables.

5. Operating Instructions

The A-BF DC Power Supply can operate in Constant Voltage (CV) or Constant Current (CC) mode, automatically switching between them based on the load.

Adjusting Voltage and Current

  1. Set Voltage: With the output OFF, turn the Voltage Regulation knob to set the desired output voltage. The display will show the set value.
  2. Set Current Limit: With the output OFF, turn the Current Regulation knob to set the desired maximum current limit. This acts as a safety feature to protect your load.
  3. Activate Output: Press the ON/OFF button to turn on the power output. The C.V. or C.C. indicator will light up depending on the operating mode.

Constant Voltage (C.V.) Mode

In C.V. mode, the output voltage remains constant at the set value, and the output current varies according to the load resistance. The C.V. indicator light will be on.

Constant Current (C.C.) Mode

In C.C. mode, the output current remains constant at the set limit, and the output voltage varies according to the load resistance. This occurs when the load resistance is low enough to draw more current than the set limit. The C.C. indicator light will be on.

Diagram illustrating Constant Voltage (C.V.) and Constant Current (C.C.) modes with their respective indicator lights and behavior.

Figure 5: Constant Voltage and Constant Current Modes

Memory Function (MP Series Only)

For MP series models, use the M1, M2, and M3 buttons to store and recall frequently used voltage and current settings. Refer to the specific MP series diagram (Figure 3) for button locations.

Quick Charge USB Output

The USB interface provides a fixed 5V/2A output for charging compatible devices. This output is independent of the main DC power output settings.

6. Maintenance

  • Cleaning: Disconnect the power supply from the main power before cleaning. Use a soft, dry cloth to wipe the exterior. Do not use abrasive cleaners or solvents.
  • Ventilation: Ensure the cooling fan and air vents on the rear and sides of the unit are free from dust and obstructions to maintain optimal heat dissipation.
  • Fuse Replacement: If the unit fails to power on, check the fuse located in the fuse holder on the rear panel. Replace it with a fuse of the same type and rating.
Internal view of the power supply showing components, cooling fan, and four-sided cooling holes.

Figure 6: Internal Design and Cooling Features

7. Troubleshooting

ProblemPossible CauseSolution
Power supply does not turn on (no response)No power from outlet, faulty power cord, loose internal cable, blown fuse.1. Check if the power cord has output. 2. Use a multimeter to test if the power outlet has voltage. 3. If there is voltage output, remove the power supply cover (if qualified) and check for loose internal cables; reinsert and try. 4. Check and replace the fuse if blown.
Output voltage/current is unstablePoor connection to load, unstable input power, unit overheating.1. Ensure all connections are secure. 2. Check input power stability. 3. Ensure adequate ventilation and clear cooling fan/vents.
Unit enters C.C. mode unexpectedlyLoad resistance is too low, drawing more current than the set limit.1. Increase the current limit if safe for your load. 2. Check the load for short circuits or excessively low resistance.

8. Specifications

General Specifications

ParameterValue
Brand NameA-BF
Output TypeSINGLE
OriginMainland China
CertificationCE, FCC
Voltage Load Regulation Rate≤0.1% + 5mV
Voltage Line Regulation Rate≤0.01% + 5mV
Voltage Setting Accuracy≤0.1% + 1 digit
Voltage Readback Accuracy≤0.1% + 1 digit
Voltage Ripple10mVrms
Current Load Regulation Rate≤0.2% + 3mA
Current Line Regulation Rate≤0.2% + 3mA
Current Setting Accuracy≤0.2% + 3mA
Current Readback Accuracy≤0.2% + 3 digits
Current Ripple8mVrms
Over Voltage Protection (OVP)0-Vmax ±0.2%FS
Over Current Protection (OCP)0-Cmax ±0.2%FS
Working Conditions Temperature0~40℃
Working Conditions Relative Humidity≤80%RH
Storage Temperature-20~60℃
Storage Relative Humidity≤80%RH
Operating VoltageAC220V±10% 50Hz (also 110V for US version)
Cooling MethodAir-cooled
Weight1.95KG
Size (bare metal)80 x 150 x 230 mm
Suggested Operating Range23°C ± 5°

Model-Specific Output Ranges

ModelOutput VoltageOutput CurrentPowerInput Voltage
SS-4020HP0~40V0~20A300W220V
SS-8010HP0~80V0~10A300W220V
SS-1605HP0~160V0~5A300W220V
SS-3010MP/SS-3010MF0~32V0~10A300W220V/110V
SS-305MP/SS-305MF0~32V0~5A150W220V/110V

9. User Tips

  • Memory Function: For MP series models, utilize the M1-M3 buttons to quickly save and recall your most used voltage and current settings, streamlining repetitive tasks.
  • Power-On Memory: The power supply remembers the last voltage and current settings from the adjustment knobs when turned off and on again, provided the knobs themselves are not moved.
  • Electronics Repair: This power supply is well-suited for repairing mobile phones, laptops, and other electronic devices due to its precise control and protection features.
  • Application Versatility: The unit is ideal for production line testing, electrical repair and maintenance, product aging tests, circuit board repair, and laboratory research and teaching.
Collage of images showing various application fields for the DC power supply, including production lines, electrical repair, product aging, circuit board repair, and laboratory use.

Figure 7: Diverse Application Fields

10. Warranty and Support

Your A-BF Lab Variable DC Power Supply is covered by a manufacturer's warranty against defects in materials and workmanship. For detailed warranty terms, technical support, or service inquiries, please refer to the contact information provided with your purchase documentation or visit the official A-BF website.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.