1. Introduction
This manual provides comprehensive instructions for the installation, operation, and maintenance of your Dooya DM45R 50/12 and DM45S 50/12 tubular motors. These motors are designed for various automated systems, including rolling blinds, canopies, and lift systems. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.

Figure 1: Dooya DM45R/DM45S 50/12 Tubular Motor
2. Safety Information
Please observe the following safety precautions to prevent injury or damage to the product:
- Ensure all electrical connections are made by a qualified professional and comply with local electrical codes.
- Disconnect power before performing any installation, maintenance, or troubleshooting.
- Do not immerse the motor in water or expose it to excessive moisture.
- Avoid striking the motor with hard objects or drilling into its casing.
- Keep children and pets away from the operating area of the motorized system.
- Do not operate the motor if it is damaged or malfunctioning.

Figure 2: Important safety warnings for motor handling and installation.
3. Package Contents
Upon unpacking, please verify that all the following items are included:
- Tubular Motor (DM45R 50/12 or DM45S 50/12) - 1 unit
- Crown - 1 unit (selected based on your chosen tube type)
- Drive Adapter - 1 unit (selected based on your chosen tube type)
Note: The specific crown and drive adapter provided will correspond to the tube type selected at the time of purchase. Please ensure these match your requirements.

Figure 3: Typical package contents including motor, crown, and drive adapter.
4. Specifications
The Dooya DM45 series tubular motors offer robust performance for various applications. Key specifications are detailed below:
General Specifications (DM45R 50/12 & DM45S 50/12)
| Attribute | Value |
|---|---|
| Rated Torque | 50 Nm |
| Rolling Speed | 12 r/min |
| Voltage | 220/230V |
| Frequency | 50/60 Hz |
| Wattage | 205W |
| Current | 0.89A |
| Motor Diameter | 45mm |
| Protection Degree | IP44 |
| Certification | CE |
| Battery Included | No |
| Tube Compatibility | Works for 50mm/55mm/63mm tubes (and others with appropriate adapters) |
Model Specifics
- DM45R 50/12: RF433 tubular motor with 3 wires. Can work with Dooya RF433 remote controllers (e.g., DC2700, DC1650) and RF433 wall switches. Features a built-in receiver.
- DM45S 50/12: 4-wire motor without an integrated RF433 module. Can work with DC227A, DC228A wall switches, and Tuya WiFi curtain wall switches.

Figure 4: Detailed parameter list for 45mm diameter motors.

Figure 5: DM45S Standard Tubular Motor specifications and internal structure.

Figure 6: DM45R Radio Tubular Motor specifications and internal structure.
5. Setup and Installation
Proper installation is crucial for the optimal performance and longevity of your tubular motor. Follow these steps carefully.
5.1 Motor Type and Wiring Distinction
The DM45 series includes two main types: the DM45R (Radio, built-in receiver) and DM45S (Standard, external control). Understanding their wiring is essential.
- DM45R (Built-in Motor): Features a built-in receiver and typically has 3 wires (Zero Line, Fire Wire, Ground Wire) and a black antenna. It is directly connected to power and controlled wirelessly.
- DM45S (External Motor): Requires an external switch or controller and typically has 4 wires (Zero Line, Fire Wire 1, Fire Wire 2, Ground Wire). It does not have a built-in RF433 module or antenna.

Figure 7: Motor distinction by wiring (4-wire external vs. 3-wire built-in).

Figure 8: Motor application notes and wiring examples for built-in and external motors.
5.2 Tube Compatibility and Adapter Selection
The motor requires a compatible tube, crown, and drive adapter. Ensure your tube's outer diameter and inner structure match the provided adapters. If your existing tube has a different inner structure, you may need to modify the adapters or source compatible ones locally.

Figure 9: Compatible tube types for the DM45 series motors.
Examples of specific crown and drive adapters for various tube types:
- For 50mm Round Tube:

- For 55mm Groove Tube:

- For 60mm Octagonal Tube:

- For 60mm Groove Tube:

- For 63mm Groove Tube:

- For 70mm Groove Tube:

- For 85mm Groove Tube:

- For 90mm Groove Tube:

For heavy-duty applications like lift systems, aluminum alloy drive adapters are recommended for enhanced durability. If you require these, please specify when ordering.
5.3 Measurement for Rolling Systems
Accurate measurements are vital for proper fit and function. Consider whether you need an outer frame or inner frame installation.
- Outer Frame Installation: For fully covered windows and full shading. Measure the width and height of the outer frame of your window.
- Inner Frame Installation: For partial light leakage. Measure the width and height of the inner frame of your window.

Figure 10: Measurement methods for outer and inner frame installations.
5.4 System Components Overview
A complete motorized rolling blinds system typically includes the following components:
- Tubular Motor
- Roll Tube
- Remote Controller (or Wall Switch)
- Bottom Rod
- Installation Brackets
- Curtain Cloth / Fabric

Figure 11: Components of a motorized roller blind system.
5.5 Bracket Installation
Install the brackets securely to the wall or ceiling according to your chosen installation method (A or B).

Figure 12: Bracket Installation Method A.

Figure 13: Bracket Installation Method B.
5.6 Circuit Installation
Connect the motor to the power supply and control unit as per the relevant diagram for your motor type and voltage. Ensure all connections are tight and insulated.
Wiring Color Code:
- Blue = Neutral
- Brown = Direction 1 (Fire Wire 1)
- Black = Direction 2 (Fire Wire 2 - for 4-wire motors)
- Yellow/Green = Earth

Figure 14: Circuit Installation A (DM45S, 230V/50Hz, 4-wire motor with external switch).

Figure 15: Circuit Installation B (DM45S, 230V/50Hz, 4-wire motor with external switch).

Figure 16: Circuit Installation C (DM45R, 230V/50Hz, 3-wire motor with built-in receiver).
6. Operation
This section details how to operate and program your Dooya tubular motor.
6.1 Limit Setting (DM45R & DM45S)
The motor's travel limits define the fully open and fully closed positions of your blinds or system. These are set using the special limit regulator on the motor head.
- Up Limit Setting:
- Switch on the power.
- Press the UP button on the emitter or switch once.
- Use the special regulator to adjust the "+" direction. Rotate the white worm to increase the up distance.
- When the desired up limit is achieved, stop rotating the white worm and press the STOP button on the emitter or switch. The motor will confirm with an "ok" signal.
- Down Limit Setting:
- Switch on the power.
- Press the DOWN button on the emitter or switch once.
- Use the special regulator to adjust the "+" direction. Rotate the red worm to increase the down distance.
- When the desired down limit is achieved, stop rotating the red worm and press the STOP button on the emitter or switch. The motor will confirm with an "ok" signal.
Important: When the motor stops, do not rotate the white limit hole (for up limit) or red limit hole (for down limit) without using the regulator.

Figure 17: DM45R Up Limit Setting.

Figure 18: DM45R Down Limit Setting.

Figure 19: DM45S Up Limit Setting.

Figure 20: DM45S Down Limit Setting.
6.2 Programming the First Transmitter (DM45R & DM45S)
To link your remote control (emitter) to the motor, follow one of these methods:
- Method 1 (Up Limit Control):
- Switch off the power for more than 10 seconds.
- Switch on the power for less than 4 seconds.
- Press the P2 button on the transmitter twice continuously. The motor will beep twice.
- Press the UP button on the transmitter. The motor will beep several times, indicating successful programming for up limit control.
- Method 2 (Down Limit Control):
- Switch off the power for more than 10 seconds.
- Switch on the power for less than 4 seconds.
- Press the P2 button on the transmitter twice continuously. The motor will beep twice.
- Press the DOWN button on the transmitter. The motor will beep several times, indicating successful programming for down limit control.
Note: The interval of re-switching power must be within 4 seconds of re-setting, otherwise the system will restore the original state. Deleting all data of the motor and programming a new emitter will also restore the original state.

Figure 21: DM45R Transmitter Programming Methods.

Figure 22: DM45S Transmitter Programming Methods.
6.3 Advanced Settings (DM45R & DM45S)
- Dot-move Setting:
- Switch on the power.
- Press the setting button once (motor beeps once).
- Press the UP button (motor beeps several times).
- Press the setting button once again (motor beeps several times). The dot-move setting is now active.
Note: Repeat the setting to cancel the function.

Figure 23: DM45R Dot-move Setting.

Figure 24: DM45S Dot-move Setting.
- Add Emitter:
- Switch on the power.
- On an already programmed emitter, press its setting button twice.
- On the new emitter you wish to add, press its setting button once. The motor will beep twice, confirming the new emitter is added.

Figure 25: DM45R Add Emitter.

Figure 26: DM45S Add Emitter.
- Cancel Emitter:
- Switch off the power.
- Switch on the power.
- Press the setting button once (motor beeps once).
- Press the STOP button (motor beeps once).
- Press the setting button once again (motor beeps several times). The emitter is now cancelled.

Figure 27: DM45R Cancel Emitter.

Figure 28: DM45S Cancel Emitter.
7. Maintenance
To ensure the longevity and smooth operation of your Dooya tubular motor, follow these simple maintenance guidelines:
- Keep the motor and surrounding area clean and free from dust and debris.
- Regularly inspect the wiring for any signs of wear or damage. Replace damaged wires immediately.
- Ensure the motor is not exposed to extreme temperatures or direct water spray.
- Do not attempt to lubricate the internal components of the motor unless specifically instructed by the manufacturer.
- If the motor is part of a rolling system, periodically check the tube, brackets, and fabric for proper alignment and wear.
8. Troubleshooting
This section provides solutions for common issues you might encounter with your tubular motor.
| Fail-phenomena | Failure Causes | Solutions / Failure Recovery |
|---|---|---|
| Switch on, the drive adapter runs in one-way operation | Inside limit switch of motor doesn't open | Crown running one circle in the opposite direction of the drive adapter, then it works. |
| Motor starts slowly or will not work after connecting power | a. Power voltage is slow b. Wiring error c. Overload d. Improper installation | a. Adjust power to rated data b. Check circuit and correct wiring connection c. Rated torque associated with the installation of the load d. Re-install the motor |
| Motor stops suddenly after running | Motor stops suddenly after running | Motor will automatically resume work after 20 minutes cooling. |
| Abnormal sound during roller blinds in operation | Outer tube is too long, led the rolling shutter connects with both sides of bracket too tightly. | If idler is active, propering make the tube shorter to avoid too tight status. |

Figure 29: Common failures and solutions for DM45R.

Figure 30: Common failures and solutions for DM45S.
9. User Tips
- Custom Applications: For non-standard applications, such as rolling up a large tarp (e.g., 4x3 meters), ensure the motor's rated torque (50Nm) and speed (12r/min) are sufficient for the weight and size of your material. Always test the system with a lighter load first.
- Adapter Customization: If the provided crown and drive adapters do not perfectly fit your specific tube, consider modifying them carefully or using a 3D printer to create custom adapters if you have the necessary skills and equipment.
- Remote Control Pairing: When pairing new remote controls, ensure you follow the power cycling and button press sequences precisely to avoid resetting existing settings.
10. Warranty and Support
For any issues not covered in this manual, or for warranty claims, please contact the seller or manufacturer's customer support. Keep your purchase receipt as proof of purchase.
The product is certified with CE, indicating compliance with European safety, health, and environmental protection requirements.