SEAFLO 14A Series (SFBP1-G1100-14A, SFBP2-G1100-14A)

Contents

SEAFLO 14A Series Automatic Bilge Pump Instruction Manual

Models: SFBP1-G1100-14A (12V), SFBP2-G1100-14A (24V)

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your SEAFLO 14A Series Narrow Low Profile Water Level Sensing Automatic Bilge Pump. Designed for marine applications, this pump offers efficient water removal from bilges, featuring automatic water level sensing and a compact, low-profile design suitable for tight spaces. Please read this manual thoroughly before installation and operation to ensure safe and optimal performance.

Video: Showcase of the SEAFLO 14A Series Automatic Bilge Pump.

2. Safety Information

  • Always disconnect power before installing, servicing, or performing any maintenance on the pump.
  • Ensure all electrical connections are waterproof and properly insulated to prevent short circuits and corrosion.
  • Use the correct fuse size as specified in the specifications table to protect the pump and electrical system.
  • Do not run the pump dry for extended periods, as this can cause damage to the motor.
  • This pump is designed for pumping water only. Do not use it for flammable liquids, chemicals, or other hazardous materials.
  • Ensure proper ventilation around the pump if installed in an enclosed space.

3. Components and Parts

The SEAFLO 14A Series Bilge Pump comes with several components for easy installation and maintenance. Refer to the exploded view diagram and parts list for identification.

Exploded view diagram of the SEAFLO 14A Series Bilge Pump

Image: Exploded view diagram of the bilge pump components.

Parts list for the SEAFLO 14A Series Bilge Pump

Image: Detailed parts list corresponding to the exploded view.

Key Components:

  • Pump Body with integrated water level sensor
  • Motor Assembly (can be sold separately)
  • Removable Strainer Base
  • Discharge Nozzle (threaded)
  • Various Hose Barb Fittings (3/4", 1", 1-1/8" straight and 1-1/8" elbow)
  • Non-return Check Valve
  • Wiring with inline fuse holder (fuse not always included, check packaging)
SEAFLO bilge pump with various hose barb fittings

Image: The bilge pump shown with its included hose barb fittings for different hose sizes.

4. Specifications

The SEAFLO 14A Series Bilge Pumps are designed for robust performance in marine environments.

Technical Specifications
ModelFlow RateVoltsCurrentHeadMode of OperationOutlet Dia.
SFBP1-G1100-14A1100 GPH12V4.2A4.0m/13'Water level sensor automatic mode3/4" (19mm), 1" (25mm), 1-1/8" (29mm)
SFBP2-G1100-14A1100 GPH24V3.0A4.0m/13'

Table: Specifications for 12V and 24V models.

Performance curve for 1100 GPH 12V bilge pump

Image: Performance curve showing head vs. flow rate for the 1100 GPH 12V model.

General Specifications:

  • Structure: Submersible Pump
  • Pressure: Low Pressure
  • Power: Electric
  • Certification: CE, RoHS, ISO 8846, ISO 8849 standards
  • Ignition Protected: Yes
  • Drain Down Level: As low as 10mm (1/3")
  • Discharge Rotation: 360 degrees for flexible installation
  • Motor Shaft: Stainless-steel
  • Impeller: Five-blade for high flow rate
  • Wiring: Marine grade silicon blocked, tin coated
Dimensional drawing of the SEAFLO 14A Series Bilge Pump

Image: Dimensional drawing with measurements in millimeters.

5. Setup and Installation

Proper installation is crucial for the efficient and safe operation of your bilge pump.

5.1 Mounting Directions

The pump can be mounted horizontally or vertically. Choose a location in the lowest part of the bilge where water collects. Ensure the pump is easily accessible for inspection and cleaning.

Mounting directions for SEAFLO bilge pump, showing correct and incorrect orientations

Image: Mounting directions, illustrating acceptable and unacceptable pump orientations.

  1. Remove the motor assembly from the base by twisting and unlocking.
  2. Secure the pump base to a solid surface using 2*M4 screws.
  3. Reattach the motor assembly to the installed base, ensuring it locks securely.
Diagram showing various mounting options for the bilge pump, including side mounting, narrow bilge, shallow bilge, under cockpit, power boat, and sail boat installations.

Image: Various mounting options for different bilge configurations.

5.2 Plumbing Connections

The pump features a 360-degree rotatable discharge for flexible plumbing. Select the appropriate hose barb fitting for your discharge hose.

  • Attach the chosen hose barb fitting (3/4", 1", or 1-1/8") to the pump's discharge nozzle.
  • Connect a marine-grade discharge hose to the fitting and secure it with a hose clamp.
  • Route the discharge hose upwards to a through-hull fitting, ensuring a continuous upward slope to prevent backflow. The integrated non-return valve helps prevent water from re-entering the bilge.
  • The pump body can rotate 360 degrees to align with your plumbing.
Detailed diagram of bilge pump features including discharge nozzle, rotation, air vents, and strainer

Image: Diagram highlighting the rotatable discharge nozzle, hidden air vents, and easy-to-clean strainer.

5.3 Electrical Wiring

Refer to the wiring diagram for correct electrical connections. Use marine-grade wire and connectors.

Wiring diagram for SEAFLO 14A Series Bilge Pump

Image: Wiring diagram for connecting the bilge pump to a 12V DC power source, showing manual and automatic modes.

  • Connect the Black wire to the negative (-) terminal of your 12V or 24V DC power source.
  • For Manual mode operation, connect the Brown wire to a switched positive (+) power source (e.g., a manual bilge pump switch). Ensure an appropriate fuse is installed in this line.
  • For Automatic mode operation (water level sensing), connect the Brown & White wire to a constant positive (+) power source. An appropriate fuse must be installed in this line.
  • It is recommended to use a three-way switch (AUTO-OFF-MANUAL) for optimal control.
  • Ensure all connections are watertight and protected from corrosion.

6. Operation

The SEAFLO 14A Series Bilge Pump operates automatically based on water level sensing.

  • Automatic Mode: When connected via the Brown & White wire, the pump will automatically turn on when the water level reaches approximately 4.5cm (1.77 inches). It will continue to pump until the water level drops to 1-3cm, and then stop when the current is less than 2.2A for 15 seconds.
  • Manual Mode: When connected via the Brown wire to a manual switch, the pump can be activated or deactivated manually, regardless of the water level.
  • Anti-Airlock Protection: Hidden air vents in the pump body help prevent air locking, ensuring consistent operation.
  • Low Profile Strainer: The design allows the pump to remove water down to very low levels, leaving the bilge almost dry.

7. Maintenance

Regular maintenance will prolong the life and efficiency of your bilge pump.

  • Strainer Cleaning: Periodically inspect and clean the removable strainer to prevent debris from clogging the pump. To clean, simply unlock and remove the motor assembly from the base, then clear any accumulated debris from the strainer.
  • Electrical Connections: Check all electrical connections for corrosion or loose wiring. Apply dielectric grease to connections to prevent moisture ingress.
  • Hose Inspection: Inspect the discharge hose for kinks, cracks, or blockages. Ensure hose clamps are secure.
  • Functionality Test: Regularly test the pump's automatic and manual functions by adding water to the bilge or activating the manual switch.
  • Winterization: In freezing climates, ensure the pump and plumbing are drained or protected from freezing to prevent damage.

8. Troubleshooting

If your bilge pump is not operating as expected, check the following common issues:

  • Pump not running:
    • Check power supply and fuse. Replace blown fuses with the correct amperage.
    • Verify all electrical connections are secure and free of corrosion.
    • Ensure the water level is high enough to activate the automatic sensor (if in auto mode).
    • Inspect for debris jamming the impeller.
  • Pump runs but no water or low flow:
    • Check for clogged strainer or discharge hose.
    • Ensure the pump is fully submerged and not air-locked.
    • Verify the discharge hose is not kinked or obstructed.
    • Check for leaks in the discharge plumbing.
  • Pump runs continuously:
    • Check if the automatic sensor is stuck in the 'on' position due to debris.
    • Ensure the water level is actually dropping below the 'off' threshold.
    • Verify the non-return valve is functioning correctly to prevent backflow.

9. User Tips

  • Regular Checks: Make it a habit to visually inspect your bilge pump and its connections regularly, especially before and after each use of your vessel.
  • Proper Fuse: Always use the recommended fuse size (e.g., 8A for 12V models) to protect the pump and your boat's electrical system from overcurrent.
  • Accessibility: When installing, consider future maintenance. The quick-connect design makes it easy to remove the motor, so ensure you have enough space to access it.
  • Battery Health: Ensure your boat's battery is in good condition and adequately charged, especially for automatic operation, to prevent pump failure due to low voltage.
  • Spare Parts: Keeping spare fuses and possibly a spare impeller or motor can be beneficial for quick repairs while on the water.

10. Warranty and Support

For warranty information, technical support, or replacement parts, please contact your original point of purchase or the manufacturer directly. Keep your purchase receipt as proof of purchase.

© 2023 SEAFLO. All rights reserved.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.