1. Introduction

This manual provides comprehensive instructions for the installation, setup, operation, and troubleshooting of your Dooya DM45RQ or DM45Q Silent Fast Rolling Tubular Motor. These motors are designed for use with rolling blinds and canopies, offering quiet and efficient operation.

Dooya Silent Fast Rolling Tubular Motor
Dooya Silent Fast Rolling Tubular Motor (DM45RQ/DM45Q)

2. Product Variants

The Dooya DM45 series tubular motors come in two main variants:

  • DM45RQ 6/28 (Radio Tubular Motor):
    This model features a built-in RF433 receiver and uses a 3-wire connection. It is compatible with Dooya RF433 remote controllers (e.g., DC2700, DC1650) and RF433 wall switches.
  • DM45Q 6/28 (Quiet Tubular Motor):
    This is a 4-wire motor without a built-in RF433 module. It is designed to work with wired wall switches such as DC227A, DC228A, and Tuya WiFi curtain wall switches. It can also be controlled via a remote controller if paired with an external receiver.

3. Package Contents

Your package should contain the following items:

  • 1 x Tubular Motor (DM45RQ 6/28 or DM45Q 6/28, based on your selection)
  • 1 x Crown
  • 1 x Drive Adapter

Note: The specific crown and drive adapter provided will be selected based on the type of rolling tube you intend to use with the motor.

4. Accessories and Tube Compatibility

Proper selection of the crown and drive adapter is crucial for correct motor function with your rolling tube. Different tube types have varying inner structures, even if their outer diameter is the same.

4.1. Important Considerations for Crown and Drive Adapters

  • For rolling tubes with the same outer diameter, there are many different inner structures across various regions. We provide crowns and drive adapters from Dooya's original package for specific tube types. Please verify compatibility before installation.
  • In some cases, you may need to modify the provided crown and drive adapter to ensure they work correctly with your specific tube.
  • Some users successfully create custom crowns and drive adapters using 3D printing.
  • Alternatively, you may need to source compatible crowns and drive adapters from your local market.
  • If your existing crown and drive adapter are still functional and compatible, reusing them is often the best option.

4.2. Compatible Tube Types and Accessories

The DM45 tubular motor is compatible with various tube types. Below are examples of crowns and drive adapters for common tube sizes:

Diagram of inner and outer frame installation methods for blinds, with measurement guidelines.
Diagram illustrating inner and outer frame installation methods for blinds, with measurement guidelines. For inner installation, calculate (Actual width - 1cm) * (Actual height). For outer installation, calculate (Actual width + 20cm) * (Actual height + 20cm). Cloth width is not customized width.
Image showing various compatible tube types: 40mm Octagonal, 40mm Tube, 45mm Tube, 47mm Grooved, 50mm Round, 50mm Grooved, 55mm Tube, 63mm Tube, 83mm Tube.
Various compatible tube types: 40mm Octagonal, 40mm Tube, 45mm Tube, 47mm Grooved, 50mm Round, 50mm Grooved, 55mm Tube, 63mm Tube, 83mm Tube.
Accessories for DM45 Tubular Motor, including brackets, drive wheel, crown, and tail plug.
Accessories for DM45 Tubular Motor, including brackets, drive wheel, crown, and tail plug.

Specific adapters for different tube types:

  • For 50mm Round Tube:
    Drive adapter for 50mm Round Tube.
    Drive adapter for 50mm Round Tube.
  • For 55mm Groove Tube:
    Crown and drive adapter for 55mm Groove Tube.
    Crown and drive adapter for 55mm Groove Tube.
  • For 60mm Octagonal Tube:
    Crown and drive adapter for 60mm Octagonal Tube.
    Crown and drive adapter for 60mm Octagonal Tube.
  • For 60mm Groove Tube:
    Crown and drive adapter for 60mm Groove Tube.
    Crown and drive adapter for 60mm Groove Tube.
  • For 63mm Groove Tube:
    Crown and drive adapter for 63mm Groove Tube.
    Crown and drive adapter for 63mm Groove Tube.
  • For 70mm Groove Tube:
    Crown and drive adapter for 70mm Groove Tube.
    Crown and drive adapter for 70mm Groove Tube.
  • For 85mm Groove Tube:
    Crown and drive adapter for 85mm Groove Tube.
    Crown and drive adapter for 85mm Groove Tube.
  • For 90mm Groove Tube:
    Crown and drive adapter for 90mm Groove Tube.
    Crown and drive adapter for 90mm Groove Tube.

5. Specifications

Key technical specifications for the Dooya DM45RQ and DM45Q tubular motors:

FeatureSpecification
Model NumbersDM45RQ 6/28, DM45Q 6/28
Rated Torque6 Nm
Rolling Speed28 r/min
Voltage220/230V
Frequency50/60Hz
Wattage121W
Current0.53A
Motor Diameter45mm
Insulation GradeH
Protection DegreeIP44
CertificationCE
Battery IncludedNo
Nameplate for DM45RQ-6/28 Radio Tubular Motor, showing specifications.
Nameplate for DM45RQ-6/28 Radio Tubular Motor, showing specifications.
Nameplate for DM45Q-6/28 Quiet Tubular Motor, showing specifications.
Nameplate for DM45Q-6/28 Quiet Tubular Motor, showing specifications.

6. Installation and Setup

6.1. General Safety Precautions

  • Ensure power is disconnected before performing any installation or wiring.
  • Installation should be performed by a qualified professional if you are unsure.
  • Do not immerse the motor in water or drill into the motor casing.
  • Avoid striking the motor with hard objects.
Attention: Do not immerse motor in water, strike with hammer, or drill into casing.
Attention: Do not immerse motor in water, strike with hammer, or drill into casing.

6.2. Crown and Drive Adapter Installation

Install the crown and drive adapter onto the motor shaft as shown in the diagram. Ensure they are securely fitted. Forbidden to drill through crown and inner gear wheel.

Installation steps for Crown and Drive Adapter.
Step 1: Crown Installation - Slide the crown onto the motor shaft. Step 2: Drive Adapter Installation - Slide the drive adapter onto the motor shaft. Use rivet or screw to install drive adapter.

6.3. Bracket Installation

Mount the motor using the appropriate brackets for your installation type (A or B). Ensure the brackets are firmly secured to the mounting surface.

Bracket installation methods (A and B).
Bracket Installation A: For standard mounting. Bracket Installation B: For recessed or specific frame mounting.

6.4. Circuit Installation (Wiring)

Connect the motor to the AC power supply according to the wiring diagrams below. Ensure all connections are secure and match the voltage and frequency specified on the product nameplate (230V/50Hz or 120V/60Hz).

6.4.1. DM45RQ/DM45Q General Wiring (3-wire/4-wire)

Circuit installation diagram C for DM45RQ/DM45Q, showing wiring for AC power.
Circuit Installation C: Wiring for DM45RQ/DM45Q. Connect Blue to Neutral, Black to Direction 1, Brown to Direction 2, and Yellow/Green to Earth. For 230V/50Hz, use 3x1.5mm² wire. For 120V/60Hz, use 3x18AWG wire.

6.4.2. External Motor Wiring (4-wire)

Circuit installation diagram for a 4-wire motor, showing connections to AC power.
Circuit Installation (4-wire motor): Connect Blue to Neutral, Brown to Fire Wire 1, Black to Fire Wire 2, and Yellow/Green to Ground Wire. This setup allows for control via a mechanical manual switch for up, down, and stop functions.

6.4.3. Built-in Motor Wiring (3-wire)

Diagram of a built-in tubular motor connected directly to power, controlled by wireless switch and remote.
Built-in Motor: Directly connected to the power. Built-in receiver allows direct control by wireless switch (e.g., DC863) or wireless remote controller (e.g., DC305). This is suitable for installations without switch wiring or in small spaces.

6.5. Programming the First Transmitter (DM45RQ only)

The DM45RQ motor requires programming with a transmitter (remote control) to function wirelessly. There are two methods:

Instructions for programming the first transmitter for DM45RQ, showing two methods.
Programming the First Transmitter:
Method 1 (Up Limit Control): Switch off power for >10s, then switch on for <4s. Press the P2 button on the transmitter twice (motor beeps twice). Press the UP button (motor beeps several times). OK, Up limit control is set.
Method 2 (Down Limit Control): Switch off power for >10s, then switch on for <4s. Press the P2 button on the transmitter twice (motor beeps twice). Press the DOWN button (motor beeps several times). OK, Down limit control is set.
Note: The interval of re-switch must be within 4 seconds of re-setting, otherwise the system will restore the original state. Deleting all data of the motor and programming a new emitter will restore the original state.

6.6. Limit Setting (Up and Down)

Set the upper and lower travel limits for your blinds or canopy using the special regulator on the motor head and your emitter/switch.

Instructions for setting the upper limit of the motor.
Up Limit Setting: Switch on. Press the UP button of the emitter or switch once. Use the special regulator to adjust the '+' direction, rotating the white worm to increase the up distance. When the up limit distance is achieved, stop rotating the white worm and press the STOP button. Up limit setting is OK. Warning: When motor stops, do not rotate the white limit hole!
Instructions for setting the lower limit of the motor.
Down Limit Setting: Switch on. Press the DOWN button of the emitter or switch once. Use the special regulator to adjust the '+' direction, rotating the red worm to increase the down distance. When the down limit distance is achieved, stop rotating the red worm and press the STOP button. Down limit setting is OK. Warning: Please do not use the regulator to adjust the red and white limit screw when the tubular motor stops.

6.7. Additional Functions

6.7.1. Dot-move Setting

Instructions for dot-move setting.
Dot-move Setting: Switch on. Press the setting button once (motor beeps once). Press the UP button several times (motor beeps several times). Press the setting button once (motor beeps several times). OK, dot-move setting is complete. Note: Repeat setting to cancel the function.

6.7.2. Add Emitter

Instructions for adding an emitter (remote control).
Add Emitter: Switch on. Press the 'b' emitter's setting button twice. The motor will beep twice. Continue to press the 'a' emitter's setting button. OK, emitter adding is complete.

6.7.3. Cancel Emitter

Instructions for canceling an emitter (remote control).
Cancel Emitter: Switch on. Press the setting button once (motor beeps once). Press the STOP button (motor beeps once). Press the setting button several times. OK, emitter cancellation is complete. Note: Canceling an emitter removes all emitters from the motor's memory.

7. Operation

Once installed and configured, operate your Dooya tubular motor using the paired remote control or wall switch.

  • DM45RQ: Use the RF433 remote controller or wall switch to send commands (Up, Down, Stop).
  • DM45Q: Use the wired wall switch (e.g., DC227A, DC228A) or a compatible Tuya WiFi curtain wall switch. If an external receiver is installed, it can also be controlled by a remote.
Motor application notes, showing external motor control options (mechanical switch or receiver with remote).
Motor Application Notes: Illustrates control options for external tubular motors, including a mechanical hand switch and a remote control with a receiver switch (e.g., DC305 remote with DC254 switch).

8. Maintenance

The Dooya tubular motors are designed for low maintenance. Regular checks include:

  • Ensure the motor and wiring are free from obstructions and damage.
  • Keep the motor area clean and free of dust.
  • Periodically check that the blinds or canopy operate smoothly within their set limits.

No user-serviceable parts are inside the motor casing. Do not attempt to open or repair the motor yourself.

9. Troubleshooting

Refer to the table below for common issues and their solutions:

Table of common failures and solutions for the tubular motor.
Common Failures and Solutions:
Fall-phenomenaFailure CausesSolutions Failure Recovery
Switch on, the drive adapter runs in one-way operationInside limit switch of motor doesn't openCrown running one circle in the opposite direction of the drive adapter, then it works
Motor starts slowly or not work after connect powera. Power voltage is slow
b. Wiring error
c. Overload
d. Improper installation
a. Adjust power to rated data
b. Check circuit and correct wiring connecting
c. Rated torque associated with the installation of the load
d. Re-install the motor
Motor stops suddenly after runningMotor stops suddenly after runningMotor will automatically resume work after 20 minutes cooling
Abnormal sound during roller blinds in operationOuter tube is too long, led the rolling shutter connects with both sides of bracket; too tightlyIf idler is active, properly make the tube shorter to avoid too tight status.

10. User Tips

  • When selecting a motor, consider whether you need RF433 wireless control (DM45RQ) or prefer wired control with potential for external smart home integration (DM45Q).
  • Always double-check the compatibility of your rolling tube with the provided crown and drive adapter. Modifications or sourcing local parts might be necessary.
  • For optimal performance and longevity, ensure the motor is installed correctly and the limits are set accurately.
  • If you experience any issues, consult the troubleshooting guide before attempting any repairs.

11. Warranty and Support

For warranty information and technical support, please refer to the documentation provided at the time of purchase or contact your seller directly. Keep your purchase records for any warranty claims.

Related Documents - DM45RQ/DM45Q

Preview DOOYA Radio Tubular Motor - Specifications, Setup, and Troubleshooting
Comprehensive guide to DOOYA AC Tubular Motors, covering technical specifications, step-by-step setup procedures for dot-move, adding/canceling emitters, and a detailed troubleshooting section for common issues.
Preview Dooya Tubular Motors for Interior Applications - 2019 Product Catalogue
Explore the 2019 Dooya product catalogue featuring a comprehensive range of tubular motors for interior applications. Discover innovative solutions for blinds, curtains, and more, with a focus on quality and global reach.
Preview Dooya Tubular Motor DM45RD - Kirsch User Guide and Instructions
User guide for the Dooya Tubular motor DM45RD by Kirsch, detailing installation, remote control pairing, light adjustment, limit settings, and thermal protection.
Preview DM28LEU/SH DC Tubular Motor User Manual
Comprehensive installation and operation guide for the Dooya DM28LEU/SH DC tubular motor, designed for motorized roller blinds.
Preview DM Tubular Motor Specification and Installation Guide
Comprehensive guide for DM series radio tubular motors, covering installation, programming, limit setting, and troubleshooting for automated blinds and roller shutters. Includes technical specifications and compatibility information.
Preview Dooya DM92M Manual Tubular Motor: Specification, Installation, and Operation Guide
Comprehensive guide to the Dooya DM92M Manual Tubular Motor, covering specifications, circuit installation, limit setting, troubleshooting, and control system compatibility. Ideal for automated blinds and shades.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.