EARUELETRIC EAPDX Series

EARU Electric Dual Display Over/Under Voltage and Over Current Protector User Manual

Brand: EARUELETRIC | Model: EAPDX Series

1. Introduction

The EARU Electric EAPDX series is a range of adjustable digital over/under voltage and over current protection relays designed for single-phase AC circuits. These devices provide comprehensive protection for electrical equipment by automatically disconnecting the power supply when voltage or current exceeds preset limits and restoring it once conditions return to normal. Certain models also feature a kWh meter for energy consumption monitoring. They are designed for easy installation on a DIN rail.

2. Key Features

  • Over-voltage protection
  • Under-voltage protection
  • Over-current protection
  • Automatic recovery (self-resetting)
  • Real-time Voltage display (voltage measurement)
  • Real-time Current display (current measurement)
  • kWh display (energy consumption measurement) on EAPDX-63VAE-RGB model

3. Product Models Overview

The EAPDX series offers several models with varying current capacities and display parameters:

Overview of EARU Electric EAPDX series models showing display types and protection ranges.

Figure 1: Product Style Overview

Table 1: Model Comparison
FeatureEAPDX-40EAPDX-63EAPDX-63VAE-RGB
Model NumberEAPDX-40, EAPDX-40-RGEAPDX-63, EAPDX-63-RGEAPDX-63VAE-RGB
Over Current Protection Range1-40A1-63A1-63A
Over Voltage Protection Range240~300V240~300V230~300V
Under Voltage Protection Range140~200V140~200V80~210V
Start/Reset Delay1s~300s1s~300s1s~600s
Display ParameterVoltage, CurrentVoltage, CurrentVoltage, Current, kWh

4. Technical Specifications

General Specifications (Applicable to most models):

  • Rated Voltage: AC240V (220V nominal)
  • Rated Frequency: 50Hz/60HZ
  • Poles: 1P+N
  • Breaking Capacity: 6kA
  • Electric Life: ≥20000 Cycles
  • Standard: IEC60898-1/IEC60947-2
  • Tripping Time: ≤0.1S
  • Certification: CE
  • Tripping Curve: C Curve
  • Display Type: Digital Only
  • DIY Supplies: Electrical
  • Battery Included: No
  • High-concerned chemical: None
  • Error in real-time current, voltage: ≤5%

Dimensions:

EAPDX-63 Dimensions
Dimensions for EAPDX-63 model: 38mm width, 86mm height, 65mm depth, 45mm DIN rail height.
  • Width: 38mm (1.5in)
  • Height: 86mm (3.39in)
  • Depth: 65mm (2.56in)
  • DIN Rail Height: 45mm (1.77in)
EAPDX-63VAE-RGB Dimensions
Dimensions for EAPDX-63VAE-RGB model: 38mm width, 86mm height, 68mm depth, 46mm DIN rail height.
  • Width: 38mm (1.5in)
  • Height: 86mm (3.39in)
  • Depth: 68mm (2.68in)
  • DIN Rail Height: 46mm (1.81in)

5. Setup & Installation

Safety Warning: Installation should only be performed by qualified personnel. Ensure power is disconnected before installation to prevent electric shock.

Mounting:

The EAPDX series protectors are designed for DIN rail mounting. Snap the device onto a standard 35mm DIN rail in your electrical panel.

Wiring Diagram:

Connect the device according to the wiring diagrams below. Ensure correct connection of the Neutral (N) and Live (L) wires for both input (IN) and output (OUT) terminals.

EAPDX-63 Wiring
Wiring diagram for EAPDX-63 model, showing input (IN) and output (OUT) terminals for Neutral (N) and Live (L) connections, typically connected in series with a circuit breaker.

Figure 2: EAPDX-63 Wiring Diagram

EAPDX-63VAE-RGB Wiring
Wiring diagram for EAPDX-63VAE-RGB model, showing input (IN) and output (OUT) terminals for Neutral (N) and Live (L) connections, typically connected in series with a circuit breaker.

Figure 3: EAPDX-63VAE-RGB Wiring Diagram

6. Operating Instructions

The device features a digital display and control buttons (UP, DOWN, SET, Power On/Off) for parameter adjustment. Refer to the video demonstration for a visual guide on setting parameters.

Video 1: Demonstration of device operation and setting adjustments.

Entering Setting Mode:

Press and hold the 'SET' button for more than 3 seconds to enter the setting state. Use the UP and DOWN buttons to adjust values and 'SET' to confirm and move to the next parameter.

Setting Menu for EAPDX-40/63 Models:

Function setting menu for EAPDX-40 and EAPDX-63 models, detailing parameters like overvoltage, undervoltage, overcurrent settings, and delay times.

Figure 4: EAPDX-40/63 Function Setting Menu

  • 220: Display voltage (default/current reading)
  • P-1: Overvoltage setting (Adjustable range: 240-300V-OFF)
  • P-2: Undervoltage setting (Adjustable range: 140-200V-OFF)
  • P-3: Overcurrent setting (Adjustable range: 1A-40A/63A/80A, depending on model)
  • P-4: Reset/start delay (Adjustable range: 1s-300s)
  • P-5: Relay recovery delay (Adjustable range: 1s-300s)
  • P-6: Overcurrent Recovery Delay (Adjustable range: 1s-300s)

Setting Menu for EAPDX-63VAE-RGB Model:

Detailed settings menu for EAPDX-63VAE-RGB model, including power-on delay, protection recovery delay, over/under voltage settings, current protection, and calibration options.

Figure 5: EAPDX-63VAE-RGB Settings Menu

  • Pt: Power-on delay time (1s-600s)
  • rE: Protection recovery delay (1s-600s)
  • 30: Over-voltage protection setting (230V-300V)
  • oUr: Over-voltage recovery setting (225V-295V)
  • nO: Undervoltage protection setting (80V-210V)
  • Urr: Undervoltage recovery setting (85V-215V)
  • Uct: Over-under-voltage protection action delay time (0.1s-10s)
  • URd: Calibration Voltage Value (-9.9V~9.9V)
  • oFF: Over current protection value (1-63A)
  • oLt: Overcurrent protection action time (0.1s-60s)
  • Ctt: Overcurrent protection continuous times (0-20)
  • CrA: Current Calibration (-9.9A~9.9A)
  • PC: Power range setting (1-999)
  • CLP: Reset mode (CLP 000 Reset setting, CLP 006 Reset power level, CLP 009 Restore Factory Settings)

7. Maintenance

  • Regularly inspect the device for any signs of physical damage or loose connections.
  • Keep the device clean and free from dust and moisture.
  • Ensure proper ventilation around the device to prevent overheating.
  • Do not attempt to open or repair the device yourself. Refer to qualified technicians for service.

8. Troubleshooting

  • Device not powering on: Check the input power supply and ensure all wiring connections are secure.
  • Device trips frequently: Verify that the over-voltage, under-voltage, and over-current protection settings are appropriate for your load and power supply. Adjust delay times if necessary to avoid nuisance tripping.
  • Incorrect voltage/current readings: Check the calibration settings (URd for voltage, CrA for current) and adjust if needed. Ensure the device is correctly wired.
  • Device does not reset automatically: Check the recovery delay settings (P-4/P-5/rE) and ensure they are configured for automatic recovery.

9. User Tips

  • When setting protection parameters, always start with values slightly above or below your normal operating range to prevent immediate tripping.
  • Utilize the adjustable delay times (Power-on delay, Recovery delay) to prevent false trips during momentary fluctuations or when equipment starts up.
  • For models with kWh display, periodically monitor energy consumption to identify potential inefficiencies or unexpected load changes.
  • Always ensure the device's current rating matches or exceeds the maximum expected load current to prevent damage to the protector.

10. Warranty & Support

For any technical assistance, warranty claims, or product inquiries, please contact the seller or manufacturer directly. Keep your purchase records for reference.


Related Documents - EAPDX-40

Preview EAPDX-40/63 Series Adjustable Voltage & Current Protector User Manual
User manual for the EARU EAPDX-40/63 series adjustable voltage and current protector. Includes technical specifications, installation instructions, and operation guide for setting protection parameters.
Preview EARU EAPDX Series: Instruction Manual for Three Phase Voltage Current Protection Relay
This instruction manual provides essential information for the EARU EAPDX Series Three Phase Voltage Current Adjustable Over Under Voltage Current Limit Protection Relay. Learn about product features, safety instructions, and setup for optimal performance and system protection.
Preview EAPDX-40/63 Series Earu Electric Voltage & Current Protector User Manual
Detailed specifications and operation guide for the Earu Electric EAPDX-40/63 series adjustable voltage and current protector. Learn how to set over-voltage, under-voltage, and over-current protection parameters.
Preview EARU EAPDX-63AVE-RGB Power Energy Meter & Voltage Protection Manual
Official instruction manual for the EARU EAPDX-63AVE-RGB Power Energy Meter. Learn about its features for measuring, recording, and analyzing electric energy, plus its over/under voltage protection capabilities for power systems.
Preview EARU Miniature Current Circuit Breaker Instruction Manual - Safety and Operation Guide
This instruction manual from EARU ELECTRIC provides essential safety information and operational guidance for Miniature Current Circuit Breakers (MCBs), including models like AFDD-63 and EAB6L, ensuring safe and optimal performance in low-voltage power distribution systems.
Preview EARU EACBDC Din Rail Circuit Breaker Instruction Manual
Instruction manual for the EARU EACBDC series Din Rail Circuit Breaker. Provides important safety information, product description, and technical parameters for reliable overload and short-circuit protection.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.