DWIN DMG80480L070_01WTR

DWIN 7.0 Inch Display LCD HMI Intelligent Module User Manual

Model: DMG80480L070_01WTR

Brand: DWIN

1. Introduction

This manual provides detailed instructions for the DWIN 7.0 Inch Display LCD HMI Intelligent Module, model DMG80480L070_01WTR. This module features a resistive touch panel and is designed for various human-machine interface applications. It operates on the T5L platform and supports two development modes: DGUS II and TA (Instruction set).

The DWIN HMI module is equipped with a T5L ASIC, offering a consumer-grade solution for UI design and control. It supports animation, data, text, and curve display without extensive coding, thanks to its independent GUI and OS kernel.

2. Key Features

  • T5L platform, 7.0 Inch, 16.7M Colors, 800*480 Pixel TFT LCD
  • Resistive touch panel
  • TTL/RS232 communication interfaces
  • 8Pin_2.0mm connection wire
  • Two Development modes: DGUS II / TA (Instruction set)
  • Support for animation, data, text, curve display without complex coding
  • Independent GUI and OS kernel, programmable with DWIN OS language or Keil C51

3. Specifications

3.1 Display Parameters

ParameterValue
LCD TypeTN, TFT LCD
Viewing AngleNormal viewing angle, 70°/70°/50°/70° (L/R/U/D)
Resolution800×480 pixels (0°/90°/180°/270°)
Color24-bit 8R8G8B (16.7M Colors)
Active Area (A.A.)153.8mm (W) × 85.6mm (H)
Visual Area (V.A.)156.4mm (W) × 88.5mm (H)
Backlight ModeLED
Backlight Service Life>10000 hours (Time of the brightness decaying to 50% on the condition of continuous working with the maximum brightness)
Brightness200 nit
Brightness Control0~100 grade (When the brightness is adjusted to 1%~30% of the maximum brightness, flickering may occur and is not recommended to use in this range)

3.2 Serial Interface Parameters

ParameterValue
ModeDetermined by Jumper: Default to TTL/CMOS mode. ON = TTL/CMOS; OFF = RS232
Baud Rate3150~3225600bps, typical value of 115200bps
Data FormatN81
Interface Cable8Pin_2.0mm

3.3 Electrical Specifications

ParameterValueCondition
Rated Power<5W-
Operating Voltage6.0~15.0VTypical value of 12V
Operating Current200mAVCC=12V, max backlight
80mAVCC=12V, backlight off
Recommended power supply: 12V 1A DC

3.4 Operating Environment

ParameterValue
Operating Temperature-20℃~70℃ (12V @ 60% RH)
Storage Temperature-30℃~80℃
Conformal CoatingNone
Operating Humidity10%~90%RH, typical value of 60% RH

4. Setup and Connections

Before assembling the DWIN LCD module into your system, it is crucial to first update the program to the LCD. Refer to the "Operating" section for development and programming instructions.

4.1 Product Components

The DWIN 7.0 Inch Display LCD HMI Intelligent Module typically includes the following accessories:

Product Accessories: DWIN LCD module, HDL65011 cable, HDL65013 cable, 8Pin 2.0mm connector, SD001 SD card.

Figure 1: Product Accessories (DWIN LCD module, HDL65011 cable, HDL65013 cable, 8Pin 2.0mm connector, SD001 SD card)

  • DWIN 7.0 Inch Display LCD HMI Intelligent Module
  • HDL65011 Cable
  • HDL65013 Cable
  • 8Pin 2.0mm Connector
  • SD001 SD Card

4.2 Hardware Interfaces

The module features several interfaces for connectivity and control. Understanding these interfaces is essential for proper setup.

Integrated LCD with CPU: Diagram showing SD Card, T5L ASIC, LCM interface, PGT05 interface, Buzzer, TP interface, OFF=RS232, User interface.

Figure 2: Hardware Interfaces (Rear View with Labels)

  • **SD Card Interface**: For loading firmware and project files.
  • **T5L ASIC**: The core processor of the module.
  • **LCM Interface**: Liquid Crystal Module interface.
  • **PGT05 Interface**: Programming interface.
  • **Buzzer**: For audio feedback.
  • **TP Interface**: Touch Panel interface.
  • **ON=TTL OFF=RS232 Switch**: Jumper setting for serial communication mode.
  • **User Interface**: Main connection point for external devices (8Pin_2.0mm).

4.3 Dimensional Drawing

For precise integration, refer to the dimensional drawing below. All dimensions are in millimeters.

Dimensional Drawing of DWIN 7.0 Inch Display LCD HMI Module, showing front, side, and back views with measurements in millimeters. Key dimensions include bezel, active area, and mounting hole positions.

Figure 3: Dimensional Drawing

5. Operation and Development

The DWIN HMI module is designed for easy UI development and interaction. It supports two main development modes: DGUS II and TA (Instruction set).

5.1 DGUS Software for UI Design

The DGUS software facilitates quick UI development with zero code. It allows for the integration of images, icons, and fonts to create rich and splendid display effects.

DGUS Software: Screenshot of the DGUS software interface showing options for Image, Icons, and Fonts for UI design.

Figure 4: DGUS Software Interface

5.2 Functional Capabilities

The module supports various functions including image animation, basic graphics, QR code display, roll text, data input & display, and touch control.

Function: Diagram illustrating various functions like Image Animation, Basic Graphic, QR Code, Roll Text, Data Input & Display, and Touch Control.

Figure 5: Functional Capabilities

5.3 Working Principle

The Smart TFT Display with CPU communicates with an external MCU controller via UART instructions to control the display and interact with equipment.

Working Principle: Diagram showing Smart TFT Display with CPU sending UART instructions to an MCU controller, which then interacts with various equipment.

Figure 6: Working Principle Diagram

5.4 Touch Panel Customization

The touch panel offers various customization options including shape (Radian, Pierced, 2.5d), color (logo customized, black/white/silver panel), surface treatment (UV-proof, fingerprint-proof), and variety of interfaces (USB, IIC).

Variety of touch panel customizable: Images showing different shapes, colors, surface treatments, and interfaces (USB, IIC) for the touch panel.

Figure 7: Touch Panel Customization Options

5.5 Demonstration Video

Watch this video to see the DWIN HMI module's touch functionality and UI capabilities in action.

Video 1: DWIN HMI Module Touch Functionality Demonstration

6. Maintenance

To ensure the longevity and optimal performance of your DWIN LCD HMI module, follow these maintenance guidelines:

  • **Cleaning**: Use a soft, lint-free cloth slightly dampened with water or a mild, non-abrasive screen cleaner. Avoid harsh chemicals, alcohol, or ammonia-based cleaners, as they can damage the screen surface.
  • **Handling**: Always handle the module by its edges. Avoid applying excessive pressure to the screen or internal components.
  • **Environment**: Operate and store the module within the specified temperature and humidity ranges to prevent damage. Avoid direct sunlight and extreme temperature fluctuations.
  • **Power Supply**: Use a stable 12V 1A DC power supply as recommended to prevent electrical damage.
  • **Connections**: Ensure all cables are securely connected. Periodically check for any loose connections or damaged wiring.

7. Troubleshooting (FAQ)

This section addresses common questions and issues you might encounter.

Q: How can I start development with a DWIN LCD Module? Can I assemble it directly on my machine?
A: No, you should update the program to the LCD first, and then assemble it. The process involves:
  1. Check the software platform of the screen (mentioned in the datasheet).
  2. Use the correct development SDK (different platforms use different SDKs) to finish developing.
  3. Update the software program and test.
  4. Once testing is successful, assemble it on your machine.
Q: What industries are DWIN LCDs used in?
A: DWIN LCDs are used in a wide range of industries, including beauty machines, physical therapy equipment, health and fitness devices, medical treatment systems, air treatment and control systems, transportation (car & ship instruments), industrial instruments and apparatus automation, electricity, water treatment, IC design and manufacture, kitchen appliances (juicers, ovens, ice machines, ice-cream machines, kitchen ventilators), new energy applications (photovoltaic, wind electricity, charging piles), and various household appliances.
Q: Does DWIN product need a Minimum Order Quantity (MOQ) when purchased?
A: No, there is no MOQ for standard DWIN products.

8. User Tips

  • Ensure proper power supply voltage (12V) and current (1A DC recommended) to avoid damage.
  • Always program and test the LCD module before final assembly into your application.
  • When developing, utilize the DGUS software's zero-code quick development features for efficient UI design.
  • For optimal display performance, avoid setting brightness below 1% or above 30% of maximum if flickering occurs.

9. Warranty and Support

For product inquiries, after-sales service, and technical support, DWIN provides several channels:

DWIN Technology is committed to providing long-term supply and stable quality products, backed by professional technical service teams.