1. Introduction
This manual provides detailed instructions for the installation, operation, and parameter adjustment of the VOTOL EM200/2 V2 160A 4-6KW EMC BLDC Controller. It is designed for use with electric hub and mid-drive motors. Please read this manual carefully before starting any operation to ensure proper functionality and safety.
It is forbidden for non-specialists to use this software and controller without proper guidance.
2. Safety Information and Disclaimer
For the IV generation of EM series controller program updates and parameter adjustment, operations must only be performed by professional and technical personnel.
Without the written permission of the manufacturer, application updates to download and parameter adjustments of the IV VOTOL generation EM series controller are not allowed.
The manufacturer will not be responsible for any accidents caused by improper use or unauthorized operations.
3. Product Overview
3.1 Kit Contents
The package includes:
- 1 pcs EM-200/2 V2 Controller
- 1 pcs 485 USB Cable for Programming

3.2 Key Features and Specifications
- Model: EM-200/2 ECU sine wave controller
- Available Battery Voltage: 48V-72V
- Rated DC Current: 160A
- Boost DC Current: 300A
- Peak Phase Current: 550A
- Max. Power: 21600W (4-6KW nominal, up to 8KW matched motor rated power)
- Mosfets Detail: 30 FET
- Max. Efficiency: 93%
- Degree of Waterproof: IP67
- Flux Weakening Ratio: 200%
- Certification: CE, CCC
- Working Communication: Hall Sensor
- Net Weight: 2.44kg
- Dimensions: 249mm (Length) * 138mm (Width) * 74mm (Height)
- Material: Aluminum
- Design: Programmable sine wave
- Origin: Mainland China
- Support: Programmable by PC
3.3 Interface Description
The controller features various ports for connection to your electric vehicle's components. Refer to the diagram below for a detailed overview of each interface and its function.

3.4 Dimensions
The following diagram illustrates the physical dimensions of the EM-200/2 V2 controller.

4. Setup
4.1 Software Installation (Windows 7/10 Support Only)
4.1.1 USB Driver Installation
- Download the "USB-to-serial-win 10-20150814" file and decompress it.
- Choose the suitable driver for your computer (Win 7, Win 10 are available; iOS and XP systems are not supported). For non-Chinese PC systems, remove any Chinese words from the file name if present.
- After installation, connect the USB cable to the controller and computer. If connection fails:
- Right-click "My Computer" on the desktop, then select "Device Manager".
- Navigate to "Ports (COM & LPT)".
- Choose the COM port with a "!" symbol, right-click, and select "Update software".
- Select "Browse Computer to find out the drive software".
- Select "Prolific USB-to-Serial Comm Port Version: 3.3.2.102 [2008/9/24]".
- Click "Next" to proceed with the installation, then close the software upon completion.
4.1.2 Software Installation (Newer Versions)
For versions from July 2018 onwards, steps 1 and 2 below are not needed. Only install the USB driver, then open the software directly.
- Copy the
TeeChart5.ocxfile to the C drive root directory. - Click the setup to register the file and finish the installation (allow installation if the software shows an intercept interface). After finishing, run the
EM_V3program.
4.2 Controller Connection
- Power on the controller, ensure the ignition is closed.
- If your controller supports CAN, click "CAN enable" and then "Open".
- Click the "researching" button, then choose the correct serial port from the device COM list (usually the last one). Click "open series port"; the device should show "connected".
- Turn on the ignition, then click "connect" to the controller (it is recommended to click it more than twice).
4.3 Basic Settings
4.3.1 Battery Voltage Adjustment
The voltage parameter can be freely chosen based on the hardware support of the controller. Adjustments without hardware support can damage the controller.
4.3.2 Controller Under-voltage and Soft Under-voltage Adjustment
Fill in the required under-pressure protection parameters:
- Under-voltage value: The threshold at which the controller enters hardware under-voltage protection. Set based on the battery's under-voltage value.
- Soft under-voltage: Generally set to under-voltage + 3V.
- Under-voltage variation: This is the range for under-voltage recovery. For example, if set to 63V for over-voltage and 1V for under-voltage variation, the controller will recover at 64V.
Note: Do not change under-voltage settings unnecessarily, as it can damage the battery and reduce its lifespan due to excessive discharge.
4.3.3 Controller Battery Current and Phase Current Limited Adjustment
Adjust the battery current and phase current limits. The phase current limit affects the motor torque output.
Note: Do not set values outside the specified range, as this will damage the controller.
4.3.4 Throttle Voltage Adjustment
Adjust the throttle voltage settings:
- Low protection value: Indicates throttle error.
- Starting voltage: The voltage at which the motor begins to run.
- End voltage: The voltage at which the controller considers full throttle. It is recommended to set this 0.2V lower than the actual torque voltage.
- High protection value: If the voltage exceeds this, a torque fault will be displayed.
4.3.5 Start Setting Adjustment (for tricycle gearbox only)
These settings are specific to tricycle gearboxes:
- Start torque: Used for gear combination.
- Combined torque: Force for lifting after gear clearance.
- Upward slope: Upward slope of motor torque.
- Downward slope: Downward slope of motor torque.
4.3.6 Controller and Motor Temperature Protection Function Adjustment
Configure temperature protection settings:
- Start: Temperature at which the controller limits motor torque.
- Over temperature: Temperature at which motor torque output is cut off.
- Recovery: When motor temperature drops below this value, twisting the throttle will restore motor motivation.
- Maximum: The motor's maximum allowable temperature (e.g., 150°C).
5. Operating Instructions
5.1 Parameters Setting for Sports Mode (S Gear)
This section details settings for sports mode, including current limiting, flux weakening, and automatic logout enablers.
Note: The red mark indicates flux weakening value, adjustable by motor. The yellow mark is Capacitor protection value, modification is not recommended.
- Current-limiting value for S gear (boost function): Increases battery current for more power when in S gear. Ensure values are within range to prevent controller damage.
- Flux weakening value for S gear: When the controller enters S gear, the motor will be in flux weakening condition, increasing speed. The setting range is determined by motor condition.
- Wheel hub motor, magnet high lower than 35mm: ≤1500
- Wheel hub motor, magnet high lower than 50mm: ≤2300
- Mid drive motor, surface attached magnetic steel: ≤2300
- Mid drive motor, V magnet steel: ≤3000
- Automatic logout enablers: Configure logout time (e.g., 30s after entering S gear) and recovery time.
Note: Setting values outside the range can cause motor demagnetization and damage.
5.2 Downhill Electric Brake Assist (HDC/HHC)
This function helps maintain constant speed on steep slopes. Enable "HDC Enable" and set the HDC lowest speed. Do not set this value much higher than the motor's actual RPM (e.g., real RPM * 110%~120%).
5.3 Speed Limit Setting
Enable "Speed limited enable" and set the speed ratio (0-100%). This function can be customized by the customer.
5.4 Flux Weakening & Three Speed Setting
Configure flux weakening compensation and three-speed settings.
- Flux weakening compensation factor: Generally not recommended for change.
- Three gear setting: Set the three gear ratio range from 0-100% (Low, Mid, High).
- Mid Flux-Weakening Value: Data for motor start speed. Set around 2000-6000. If no flux weakening function is desired, set to 200-500.
- Three speed mode: Choose between button or switch control.
- Soft start enable: Enables soft start for the controller. Soft start grade (1-16), lower value means softer start.
5.5 Motor Setting
- Motor pole pairs: Fill in correctly for accurate motor speed (RPM) acquisition.
- Motor type: Fill in the correct motor magnet type for motor matching. (Wheel Hub motors are surface mount; QS can set 120 hall shift for V3 motors).
- Hall phase shift angle: Adjust within -180 to 180 degrees. To change running direction, add or subtract 120 from your current data.
5.6 Choice of Speedometer Output
The controller supports two types of speedometer output: ONE-LIN speedometer and hall speedometer. The choice depends on the vehicle's speedometer. ONE-LIN communication uses a fixed agreement (xinsiwei agreement).
5.7 Moving Assist and Cruising Function
- Move assist function: Valid after checking. The speed of the transfer assist is a percentage of the motor base speed (default 10%).
- Cruise function: Valid after checking. Turn the throttle to a certain angle and maintain for more than 8 seconds to enter cruise control mode. Any operation (brake, turning handle) will exit cruise mode.
5.8 Dual Voltage Adaptive Function
This function allows the controller to automatically switch between dual voltage modes. Refer to the table below for switching thresholds:
| Mode | Volt for switching to low volt mode | Volt for switching to high volt mode |
|---|---|---|
| 48~60V | <49V | >63.5V |
| 60~72V | <61V | >77V |
| 72~84V | <72V | >93.5V |
5.9 Reversing, EBS Setting, Low Brake Selection, Starting Safety Switch Function
- Reversing speed limit: Adjust the speed limit for reversing (0-100%). Do not exceed 30% to avoid accidents.
- EBS ratio: Adjust the electronic brake force (0-100%).
- Low brake enable: When enabled, the original single-branch power-down function becomes a low-level brake.
- Safety Switch Function: When using this function, the safety switch must be pressed before starting the vehicle.
5.10 Remote Operation and Software Update
Remote operation and software updates should be performed under the guidance of a company engineer. To update software, click "opening file", choose the ".bin" file, and click "download". The file import is successful when it shows 100%.
6. Maintenance
The VOTOL EM200/2 V2 controller is designed for durability with an IP67 waterproof rating. Regular inspection of wiring connections for wear or damage is recommended. Keep the controller clean and free from excessive dust or debris. Ensure all connections are secure to prevent intermittent operation or faults.
The manufacturer tests each controller before shipment to ensure proper working condition.

7. Troubleshooting
7.1 Software Cannot Be Installed
If the software fails to install, try changing your computer's system language to English or Chinese. This issue can arise due to differences in C++ runtime environments, especially for PCs in certain countries not set to English.
7.2 Software COM Port Not Found
If your computer has COM information but the software doesn't display it, the issue is likely with the driver. Re-install the driver or try installing the "FT232 Driver".
7.3 Controller Self-Learning Work
The controller performs self-learning for "hall angle shift" data. For other data and guides, refer to the provided Dropbox link: Dropbox Guide.
7.4 Matching a New Brand Controller
For initial testing and adjustment, ensure the phase wire and hall wire connections are correct. Set the appropriate data for motor poles and hall shift. Hall shift is crucial and can be tested within a range of -180 to 180. Refer to section 5.5 for detailed motor setting guidance.
7.5 Parking Function Setting
The parking function can be activated by a button or switch. Configure the PC14 port in the software. Choose "SW" & "F" and briefly touch your parking wire to any GND wire (or connect a button). The "P" gear should appear on your display, indicating the parking function is active. For switch control, choose "LA" & "F" and connect your parking wire and GND to a switch.
7.6 Stop Twist Throttle, Motor Still Running
If the motor continues to run after stopping the throttle, try adjusting the hall shift data. Experiment with values like changing -60 to 120, and test other data. Refer to section 5.5 for hall shift settings.
7.7 How to Set Speed Limit
Select an unused function wire (e.g., sport wire) and assign it to the PB3 port in the software. Choose "24: speed_limit" and then set your desired speed limit percentage in the software's page 2. If you want a permanent speed limit without a switch, connect the speed limit wire directly to GND.
7.8 Controller Fault or Hall Error
If the controller operates normally on the road but the software shows a controller fault when connected to a PC, it's usually not a problem with the controller itself. If the controller cannot run and the software shows a hall error (with hall connected), first check all plug connections. If connections are good, test the hall voltage from the motor. Hall positive and negative should be 5V. If the three hall signal wires do not show the same voltage, the motor hall is faulty or damaged.
7.9 Test Controller Hall Error
If a controller Hall fault occurs despite all connections (battery, ignition, motor phase wire, motor hall plug) being correct, you can test the controller hall voltage:
- Connect the positive and negative battery terminals to the controller.
- Connect the ignition and power on.
- Measure the positive and negative poles of the controller Hall. It should be around 5V. If the reading is different (e.g., 0.9V), the hall port is damaged.
All controllers are tested before shipping to ensure the hall port is functional. Damage to the hall port is typically caused by incorrect wiring of the hall plug, or by plugging in a motor hall plug with a different color sequence directly, leading to damage from incorrect hall negative and positive connections.

7.10 Reverse Function Not Working
If the reverse function wire is connected correctly and the display shows 'R' gear, but the motor does not reverse, check your software parameters. Sometimes, there might be two ports configured for reverse; remove one to empty it, and the function should work.
8. Specifications
| Attribute | Value |
|---|---|
| Model | EM-200/2 ECU sine wave controller |
| Available Battery Voltage | 48V-72V |
| Rated DC Current | 160A |
| Boost DC Current | 300A |
| Peak Phase Current | 550A |
| Max. Power | 21600W (Matched Motor Rated Power: 5KW-8KW) |
| Mosfets Detail | 30 FET |
| Max. Efficiency | 93% |
| Degree of Waterproof | IP67 |
| Flux Weakening Ratio | 200% |
| Certification | CE, CCC |
| Working Communication | Hall Sensor |
| Net Weight | 2.44kg |
| Dimensions (L*W*H) | 249mm * 138mm * 74mm |
| Material | Aluminum |
| Design | Programmable sine wave |
| Origin | Mainland China |
| Programmable | Yes, by PC |
9. User Tips
- Compatibility Check: Before purchasing, ensure the controller's dimensions (249mm L x 138mm W x 74mm H) are suitable for your vehicle's frame.
- Wiring: Most functional interfaces require modification, not just plug-and-play. Carefully check the function line on your original vehicle and the speedometer's communication signal before refitting.
- Software Use: The programming software is primarily for professional use. If you lack knowledge in electric kit assembly, proceed with caution or seek expert assistance.
- Energy Efficiency: The BLDC controller is designed for energy efficiency, contributing to optimized performance of your electric vehicle.
- Durability: The controller is built to be durable and withstand various operating conditions.
10. Warranty and Support
We offer a 1-year warranty for motors and controllers. However, the buyer is responsible for return shipping costs for repair or replacement. The warranty does not cover man-made damage.
If you encounter any problems, please contact the seller for assistance. If you do not have knowledge of electric kits assembly, please make a prudent choice before purchasing.
For further detailed instructions and programming information, please refer to the official user manual PDF: VOTOL EM Controller Program Manual (PDF).