1. Introduction

The MYPIN LM8-RRD Digital Weighing Controller is a versatile instrument designed for precise weight control applications. It is compatible with various pressure and weight sensors, making it suitable for tasks such as weight control, auto accumulation, and mean calculations for up/down batch control. Featuring a clear dual LED display, it provides easy-to-read measurements and offers functions for data/peak value holding, zero clearing, and process value (PV) modification. The controller also provides an isolated auxiliary power supply (5V/80mA) to directly connect 1-4 load cells.

2. Safety Information

WARNING:

  • Do not inhale spray or fumes.
  • Keep dry. Protect from moisture.
  • Do not crush or impact the device.
  • Not for consumption. Non-edible.
  • Keep out of reach of children. Choking hazard.
  • In case of ingestion, seek medical attention immediately.
  • Please mind potential fire risk and strictly follow the instruction manual for charging and storage.
  • For disposal, please check your local authority's website for more information and dispose of the lithium-ion battery (if applicable) safely in accordance with the applicable legal requirements.

ATTENTION: Not suitable for children under 14 years.

3. Product Overview

The MYPIN LM8-RRD is a compact digital weighing controller with a user-friendly interface. It features a dual LED display for process value (PV) and set value (SV), along with indicator lights for alarm outputs (AL1, AL2) and general output (OUT). Control buttons include SET, Reset/Back, Up, and Down for easy configuration and operation.

3.1. Components Included

  • 1 x MYPIN LM8-RRD Weighing Controller
  • 2 x Mounting Brackets
  • 1 x User Manual (this document and supplementary PDF)

3.2. Front Panel

Front panel of the MYPIN LM8-RRD Digital Weighing Controller
Front panel of the controller displaying PV and SV, with control buttons and indicator LEDs.

The front panel features:

  • PV Display: Red LED digits for the Process Value (current weight).
  • SV Display: Green LED digits for the Set Value (target weight).
  • Buttons: SET, <</RST (Reset/Shift), Up Arrow, Down Arrow.
  • Indicators: AL1 (Alarm 1), AL2 (Alarm 2), OUT (General Output).

3.3. Side View and Wiring Diagram

Side view of the controller showing the wiring diagram
Side view of the controller with integrated wiring diagram.

The side of the unit provides a clear diagram for electrical connections, including AC power input, alarm outputs, common terminals, and load cell connections.

3.4. Terminal Block

Detailed view of the terminal block for wiring connections
Detailed view of the terminal block.

The terminal block allows for secure and organized wiring of all necessary inputs and outputs.

4. Specifications

FeatureSpecification
ModelLM8-RRD
MaterialABS
Dimensions (W*H*D)48mm * 48mm * 80mm
Panel Cutout (Hole Size)45mm * 91mm
Display TypeDual LED Display (Red for PV, Green for SV)
Power Supply220V/110V AC
Accuracy0.2%F.S ±2dgt
Power Consumption≤5VA
Sampling Rate≤16 times/second
InputmV (Load Cell), supports 1-4 pcs Load Cells
Output2 RELAY
Auxiliary PowerDC 5V (regularly 80mA)
DIY Supplies CategoryElectrical
OriginMainland China
CertificationNONE
Output Voltage-- (Not specified, likely depends on relay load)

5. Setup

5.1. Mounting

  1. Prepare a panel cutout with dimensions 45mm x 91mm.
  2. Insert the controller into the cutout from the front.
  3. Secure the controller using the provided mounting brackets from the rear of the panel.

5.2. Wiring Connections

Refer to the wiring diagram on the side of the unit and the detailed terminal block image for correct connections. Ensure all power is disconnected before wiring.

Wiring diagram for the MYPIN LM8-RRD controller
Wiring diagram for AC power, alarm outputs, common, and load cell connections.
Terminal block with numbered connections
Terminal block with numbered connections for precise wiring.
  • Power Supply (AC 220V/110V): Connect the main power supply to the designated AC terminals (typically marked 1, 2, 3 for AC 220V/110V).
  • Load Cell Input: The controller supports 1-4 load cells. Connect the load cell signals (EXC5V, SG-, SG+, EXC+) to the corresponding terminals (typically marked 9, 10, 11, 12). The auxiliary power (DC 5V/80mA) is provided for direct load cell connection.
  • Relay Outputs (AL1, AL2, OUT): Connect your external control devices (e.g., solenoids, motors) to the AL1, AL2, and OUT relay terminals (typically marked 4, 5, 6, 7, 8). The common (COM) terminal is shared for the relay outputs.

6. Operating Instructions

The MYPIN LM8-RRD controller is designed for intuitive operation. Specific detailed programming steps are typically found in the full user manual PDF. Below are general operational aspects:

6.1. Basic Display and Indicators

  • PV (Process Value): Displays the current measured weight from the load cell(s).
  • SV (Set Value): Displays the target weight or setpoint for control.
  • AL1/AL2 LEDs: Illuminate when Alarm 1 or Alarm 2 conditions are met, respectively.
  • OUT LED: Illuminates when the main output relay is active.

6.2. Button Functions

  • SET Button: Used to enter programming mode, confirm settings, or cycle through parameters.
  • <</RST Button: Typically used to shift digits during value entry or to reset certain functions. It may also serve as a reset button.
  • Up Arrow Button: Used to increase numerical values or navigate through menu options.
  • Down Arrow Button: Used to decrease numerical values or navigate through menu options.

6.3. Key Functions

  • Data/Peak Value Holding: The instrument supports holding the current data or the peak measured value. Refer to the full manual for activation and usage.
  • Clearing Zero: Allows for recalibration of the zero point, essential for accurate weighing.
  • PV Modification: Enables adjustment or calibration of the Process Value display.

7. User Tips

  • This controller is well-suited for automated filling and weighing systems, capable of controlling start/stop relays based on weight thresholds.
  • Ensure that the load cells used are compatible with the controller's mV input and auxiliary power specifications for optimal performance.
  • For precise calibration and advanced settings, always consult the detailed user manual PDF.

8. Maintenance

Proper maintenance ensures the longevity and accuracy of your MYPIN LM8-RRD controller.

  • Cleaning: Wipe the exterior of the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Environmental Protection: Keep the device dry and protect it from moisture, excessive dust, and corrosive fumes.
  • Physical Care: Avoid dropping or subjecting the controller to strong impacts.

9. Troubleshooting

Specific troubleshooting steps are not provided in the available data. If you encounter issues, please:

  • Verify all wiring connections are secure and correct according to the diagram.
  • Ensure the power supply is stable and within the specified voltage range.
  • Check the load cell connections and ensure they are functioning correctly.
  • Consult the comprehensive user manual PDF for detailed troubleshooting guides and error codes.

10. Warranty and Support

For detailed warranty information, technical support, and comprehensive operational instructions, please refer to the official user manual PDF provided by the manufacturer. A digital version of the user manual can be accessed via the following link:

View User Manual (PDF)

This PDF contains in-depth information on programming, calibration, and advanced features not covered in this summary manual.

© 2023 MYPIN. All rights reserved.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.