GEYA GRT8-TS Bluetooth Control Time Relay

GEYA GRT8-TS Bluetooth Timer Control Relay Instruction Manual

Model: GRT8-TS1 / GRT8-TS2

Brand: GEYA

1. Introduction

The GEYA GRT8-TS Bluetooth Time Control Relay is designed for precise timing control in various applications. It can be used for industrial equipment, lighting control, heating element control, motor and fan control, and to regularly turn loads on and off. This device offers convenient control via a mobile phone application using Bluetooth connectivity.

GEYA GRT8-TS1 and GRT8-TS2 Bluetooth Timer Switches
Figure 1: GEYA GRT8-TS1 and GRT8-TS2 Bluetooth Timer Switches

2. Setup Instructions

  1. **Enable Bluetooth**: Confirm that the Bluetooth switch of your mobile phone is turned on.
  2. **Download the APP**: Open your mobile browser (Android) to scan the QR code provided below or directly download the APP from the URL: http://47.111.97.64:8776/BTRen.apk.
  3. QR code for Android APP download and setting instructions
    Figure 2: QR code for Android APP download and setting instructions
  4. **Set the Timer**: Open the APP and set the timer according to the prompts.
    • **Note 1**: For a detailed app operation manual, please contact the after-sales department.
    • **Note 2**: When the timer needs to work in the automatic timing mode, please confirm that the relay working state displayed in the App is automatic.
  5. **Connecting Multiple Relays**: When multiple relays need to be set at the same time, multiple relays will be searched in the equipment list. At this time, press and hold the relay panel button for 3 seconds to search the equipment list again. After this, the word "wait setting" will be added after changing the equipment name of the relay. Click to enter the setting of the relay.
  6. **Restoring Factory Settings**: After 2 minutes, the equipment name will return to normal. If you need to restore the factory settings, such as forgetting the entry password, you can press and hold the button for 10 seconds.
  7. **Time Calibration**: When the red and green indicators flash at the same time, it indicates that the time needs to be calibrated. Connect the relay with the app again to automatically calibrate the time.

3. Operating Instructions

3.1. Indicator Lights

  • **Green "Un" Indicator**: This LED indicates the power status of the relay. After the power is turned on, the green indicator is always on. When the panel key is pressed, the green indicator light will flash.
  • **Red "R" Indicator**: This LED is used to indicate the relay output status, and the indication meaning is as follows:
    Red LED R statusRelay status (GRT8-TS1)Relay1 status (GRT8-TS2)Relay2 status (GRT8-TS2)
    Solid OnClosed (15-18)Closed (15-18)Closed (25-28)
    Flashing (slow)Open (15-16)Open (15-16)Open (25-26)
    Flashing (fast)(Not applicable)(Not applicable)(Not applicable)

3.2. Wiring Diagram

Ensure correct wiring according to the diagrams below for safe and proper operation. The GRT8-TS1 model features 1 SPDT output, while the GRT8-TS2 model features 2 SPDT outputs.

Detailed wiring diagrams for GRT8-TS1 and GRT8-TS2
Figure 3: Wiring Diagram for GRT8-TS1 (left) and GRT8-TS2 (right)
  • **GRT8-TS1 (1 SPDT Output)**: Connect the load to terminals 15, 16, and 18.
  • **GRT8-TS2 (2 SPDT Outputs)**: Connect the first load to terminals 15, 16, and 18 (R1). Connect the second load to terminals 25, 26, and 28 (R2).
  • **Power Supply**: Connect the AC/DC 24-240V power supply to terminals A1 and A2.

4. Maintenance

The GEYA GRT8-TS Bluetooth Timer Control Relay is designed for reliable operation with minimal maintenance. Keep the device clean and free from dust and moisture. Ensure all connections are secure. No user-serviceable parts inside. Refer to qualified personnel for any repairs.

5. Troubleshooting

  • **Device not powering on**: Check the power supply connections to terminals A1 and A2. Ensure the voltage is within the specified range (AC/DC 24-240V). Verify the green "Un" indicator is lit.
  • **Relay not switching**: Check the wiring to the load. Ensure the red "R" indicator reflects the desired output status. Verify the timer settings in the mobile app.
  • **Bluetooth connection issues**: Ensure Bluetooth is enabled on your mobile device. Make sure the device is within range. Try restarting the app or the relay. If multiple relays are present, follow the "Connecting Multiple Relays" instructions in the Setup section.
  • **Incorrect time**: If the red and green indicators flash simultaneously, the time needs calibration. Reconnect the relay with the app to automatically calibrate the time.
  • **Forgotten password or factory reset**: Press and hold the panel button for 10 seconds to restore factory settings.

6. Specifications

Technical parameters table and panel diagram for GRT8-TS1 and GRT8-TS2
Figure 4: Technical Specifications and Panel Diagram
ParameterGRT8-TS1GRT8-TS2
FunctionBluetooth time control relay
Supply terminalsA1-A2
Voltage rangeAC/DC 24-240V 50Hz
BurdenAC 0.09-3VA / DC 0.05-1.7W
Supply voltage tolerance-15% to +10%
Supply indicationgreen LED
Number of timers8-ON / 8-OFF2 x 8-ON / 2 x 8-OFF
Time settingAPP (Bluetooth connectivity)
Time deviation±2s/day
Output1 × SPDT2 × SPDT
Rated Current16A
Min. breaking capacity DC500mW
Output indicationred LED
Mechanical life1 × 107
Electrical life (AC1)1 × 105
Operating temperature-20°C to +55°C
Storage temperature-35°C to +75°C
Mounting / DIN railDIN rail EN/IEC 60715
Protection degreeIP20
Operating positionany
Overvoltage categoryIII
Pollution degree2
Max. cable size (mm²)1x2.5mm² or 2x1.5mm² 0.4Nm
Dimensions90mm × 18mm × 64mm

7. User Tips

  • **Power Interruption**: The device does not have an internal battery for retaining settings during a power cut. If a power cut occurs, the device may need to be re-setup or re-calibrated once power is restored.
  • **App Compatibility**: The mobile application is currently available for Android systems. iOS compatibility is under development.
  • **Detailed App Manual**: For comprehensive guidance on using the mobile application, contact GEYA's after-sales support.

8. Warranty and Support

GEYA products are certified to required industry standards, including CE and RoHS, ensuring quality and compliance. For any technical assistance, detailed app manuals, or support, please contact GEYA's after-sales department. You can find contact information on the GEYA website or through the provided business card image.

GEYA contact information business card
Figure 5: GEYA Contact Information

GEYA Electric is committed to providing top-quality products and service. The company was established in 2007 and focuses on research, development, and production of low voltage electrical and industrial automation control products.

Video 1: GEYA Company Overview

Related Documents - GRT8-TS Bluetooth Control Time Relay

Preview GEYA GRT8-M Multifunction Time Relay - Instruction Manual
Comprehensive instruction manual for the GEYA GRT8-M Multifunction Time Relay, detailing its applications, technical specifications, functions, wiring, and installation.
Preview GEYA GRT8-A & B Single-Function Time Relay Instruction Manual
Comprehensive instruction manual for the GEYA GRT8-A & B series single-function time relays. Covers applications, features, detailed technical specifications, model connotations, panel and wiring diagrams, function timing, time setting procedures, and physical dimensions.
Preview GEYA GRT8-A&B Single-Function Time Relay Instruction Manual
Instruction manual for the GEYA GRT8-A&B single-function time relay, detailing its applications, functions, technical specifications, panel diagrams, and wiring diagrams.
Preview GEYA GRT8-EC Dual Function Time Relay Instruction Manual
Instruction manual for the GEYA GRT8-EC dual function time relay, detailing its applications, features, technical specifications, wiring diagrams, and operational modes for industrial use.
Preview GEYA GRT8-M Multifunction Time Relay Instruction Manual
Instruction manual for the GEYA GRT8-M multifunction time relay, detailing its applications, features, technical specifications, functions, dimensions, and wiring diagrams. Provides guidance on installation and setting.
Preview GEYA GRT8 Series Digital Display Time Relay Instruction Manual
Comprehensive instruction manual for the GEYA GRT8 Series digital display time relay. Details features, 20 delay modes, technical specifications, applications in industrial automation, and operational guidance for models GRT8-X, GRT8-X1, and GRT8-X2.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.