1. Introduction
The Liludin WZ3605E is a versatile DC-DC Buck Boost Converter power module designed for various applications requiring adjustable regulated voltage and current. It features a 1.44-inch color screen display, integrated voltmeter and ammeter, and multiple protection functions. This module can both step up and step down voltage, making it suitable for laboratory power supplies, battery charging, and other electronic projects.

Figure 1: WZ3605E DC DC Buck Boost Converter
2. Safety Information
- WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
- Do not connect AC power directly to this module. It is designed for DC input only.
- Ensure the input voltage does not exceed the maximum allowable input voltage range (6.00-36.00V).
- Always observe proper polarity when connecting input and output terminals.
- Avoid short circuits on the output.
- Operate the module within its specified temperature range (-10°C to 60°C).
- Keep the module away from moisture and extreme temperatures.
3. Product Overview
3.1. Features
- 1.44-inch high-definition color screen display.
- Adjustable output voltage from 0.6V to 36.00V.
- Adjustable output current from 0 to 5.000A.
- Constant Voltage (CV) and Constant Current (CC) modes.
- Input reverse connection protection.
- 10 data storage groups (M0-M9) for quick recall of settings.
- Multiple output protections: Overvoltage Protection (OVP), Overcurrent Protection (OCP), Under Voltage Protection (LVP), Over Power Protection (OPP), Over Time Protection (OHP), Over Capacity Protection (OAP), Over Energy Protection (OWH).
- Professional equipment calibration for accuracy and stability.
3.2. Components and Display

Figure 2: Main Interface Layout
- Display: 1.44-inch color screen showing output voltage, current, power, input voltage, CV/CC status, working status, and protection indicators.
- Rotary Encoder: Used for adjusting values and navigating menus.
- ON/OFF Button: Controls the output power.
- M1/V/A Button: Short press for voltage setting/up direction. Long press for M1 data group call out/exit.
- M2/A/V Button: Short press for current setting/down direction. Long press for M2 data group call out/exit.

Figure 3: Wiring Terminals
- VIN+ / VIN-: Input positive and negative terminals.
- OUT+ / OUT-: Output positive and negative terminals.
4. Specifications

Figure 4: Detailed Product Specifications
| Parameter | Value |
|---|---|
| Model | WZ3605E |
| Display | 1.44 inch Color screen |
| Input Voltage Range | 6.00V - 36.00V |
| Output Voltage Range | 0.60V - 36.00V |
| Output Current Range | 0 - 5.000A |
| Output Power Range | 0 - 80.000W |
| Input Voltage Resolution | 0.1V |
| Output Voltage Resolution | 0.01V |
| Output Current Resolution | 0.001A |
| Input Voltage Accuracy | ±(1%+5) |
| Output Current Accuracy | ±(0.5%+5) |
| Output Ripple | 150mV |
| Operating Temperature | -10°C ~ 60°C |
| Time Range | 0 - 10000 hours (unit: S) |
| Energy Range | 0 - 99999.999WH |
| Capacity Range | 0 - 99999.999AH |
| Capacity Energy Error | ±2% |
| Screen Brightness | 0-6 levels |
| Product Size | 79mm x 43mm x 48mm |
| Net Weight | Approx. 95g |
| Package Weight | Approx. 135g |
5. Installation
5.1. Dimensions

Figure 5: Product and Opening Dimensions
- Product Size: 79mm (Length) x 43mm (Width) x 48mm (Height).
- Panel Opening Size (for embedded installation): 75mm x 39mm.
- Card Slot Size: Approximately 12.40mm x 12.17mm x 12.14mm with a slot height of 3.34mm.
5.2. Wiring
Connect the input power source to the VIN+ and VIN- terminals, ensuring correct polarity. Connect your load to the OUT+ and OUT- terminals. Refer to the wiring diagram below:

Figure 6: Input and Output Wiring
- Input Positive: Connect to VIN+
- Input Negative: Connect to VIN-
- Output Positive: Connect to OUT+
- Output Negative: Connect to OUT-
6. Operation
6.1. Output On/Off Setting
- In the off state, short press the ON/OFF button to turn on the output.
- In the open state, short press the ON/OFF button to close the output.
6.2. Set Output Voltage/Current
- From the main interface, short press the M1/V/A button to enter the voltage setting state (indicated by a reverse display).
- Rotate the rotary encoder to change the number.
- Short press the M1/V/A button again to move and cycle through the selected numbers.
- After adjustment, long press the M1/V/A button to save the current data and exit. If no operation occurs for 30 seconds, settings will automatically save.
- To set the current, follow the same principle using the M2/A/V button.
6.3. M1/M2 Data Group Quick Call Out
- From the main interface, long press the M1/V/A button. Data group 1 (M1) will be called out, and the lower part of the screen will display the data group that has been called up.
- To return to data group M0, long press the M1/V/A button again.
- For M3-M9 data groups, refer to the corresponding interface setting instructions for calling out and setting.
6.4. System Zero Out
- From the main interface, long press the rotary encoder to calibrate the output small current drift.
6.5. Interface Switching
- When no settings are selected, rotate the rotary encoder to switch between different display menus (e.g., main interface, statistics, voltage/current curve, system settings, data group settings).

Figure 7: Multi-Interface Display
7. System Settings

Figure 8: System Setting Interface
- Long press the rotary encoder or short press the M2/A/V button to enter system settings.
- The selected item will be displayed in reverse.
- Short press M1/V/A or M2/A/V to switch the selected entry.
- Rotate the encoder to adjust the setting.
- After setting, press and hold the rotary encoder to save and exit the system settings.
Available settings include:
- Power On Output: Enable/disable output upon power-up.
- Under Voltage Setting (S-LVP): Set the minimum input voltage before the module shuts off.
- Backlight Brightness (B-LED): Adjust screen brightness from 0 to 6 levels.
- Data Group (M0-M9): Select the active data group.
8. Data Group Management

Figure 9: Data Group Setting Interface
The module supports 10 data groups (M0-M9) to store different output voltage, current, and protection settings. To set a data group:
- Long press the rotary encoder or short press the M2/A/V button to enter the data group setting interface.
- Use M1/V/A or M2/A/V to switch between items.
- Rotate the encoder to adjust values.
- Long press the rotary encoder to save and exit.
Parameters that can be set for each data group:
- M-PRE: Select data group M0-M9.
- U-SET: Set the output voltage value.
- I-SET: Set the output current value.
- S-OVP: Set the overvoltage protection value.
- S-OCP: Set the overcurrent protection value.
- S-OPP: Set the over power protection value.
- S-OHP: Set the maximum run time (parameter 0 closes by default).
- S-OAP: Set the maximum capacity (parameter 0 closes by default).
- S-OWH: Set the maximum energy (parameter 0 closes by default).
9. Statistical Functions

Figure 10: Statistical Interface and Voltage/Current Curve
9.1. Statistics Run/Pause
- In the statistics interface (accessible by rotating the encoder from the main screen), short press the rotary encoder to pause the statistics.
- To resume, short press the rotary encoder again. The operation time will be counted.
9.2. Clear Statistics
- In the statistics interface, press and hold the rotary encoder to clear all statistical information (output capacity, output energy, record time).
9.3. Voltage Current Curve Interface
This interface displays a real-time voltage and current curve. Each grid represents 0.1V/0.01A, with a sampling time of 1 second.
10. Troubleshooting

Figure 11: Output Protection Status Indicators
The module provides various status indications to help diagnose issues:
| Indicator | Status | Possible Cause / Action |
|---|---|---|
| CV | Constant Voltage | Output voltage is regulated to the set value. |
| CC | Constant Current | Output current is regulated to the set value. |
| OVP | Over Voltage Status | Output voltage exceeded set OVP limit. Check load and OVP setting. |
| OCP | Over Current Status | Output current exceeded set OCP limit. Check load and OCP setting. |
| LVP | Under Voltage Status | Input voltage dropped below set LVP limit. Check input power source. |
| OPP | Over Power Status | Output power exceeded set OPP limit. Reduce load or adjust OPP. |
| OHP | Over Time Status | Operation time exceeded set OHP limit. Reset OHP or clear statistics. |
| OAH | Over Capacity Status | Output capacity exceeded set OAP limit. Reset OAP or clear statistics. |
| OWH | Over Energy Status | Output energy exceeded set OWH limit. Reset OWH or clear statistics. |
11. User Tips
- This module is highly versatile and can be effectively utilized as a power supply for various electronic projects and laboratory setups.
- The adjustable design allows for precise control over output voltage and current, making it suitable for sensitive applications.
- Always double-check your wiring before applying power to prevent damage to the module or connected devices.
- Utilize the data storage groups (M0-M9) to quickly switch between frequently used voltage and current settings.
12. Compliance
Disclaimer: ⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.