Brother HD-390A

Contents

Brother HD-390A Analog Multimeter

Instruction Manual

1. Introduction

The Brother HD-390A is a high-precision analog multimeter designed for electricians, home maintenance, and general electrical measurements. This manual provides essential information for the safe and effective use of your multimeter, covering its features, operation, and maintenance.

2. Important Safety Warnings

WARNING: READ AND UNDERSTAND THIS MANUAL BEFORE USING THE INSTRUMENT. Failure to understand and comply with the WARNING and operating instructions can result in serious or fatal injuries and/or property damage.

  • Always ensure the multimeter is in good working condition before use.
  • Do not attempt to measure voltages or currents exceeding the specified maximum ratings.
  • Use appropriate test leads and accessories.
  • Avoid contact with live circuits.
  • Ensure the battery cover is securely closed during operation.
  • Replace batteries when the low battery indicator appears to maintain accuracy.
  • Do not use the multimeter in wet environments or explosive atmospheres.

3. Package Contents

Upon unpacking, please verify that all items listed below are present and undamaged:

  • Brother HD-390A Analog Multimeter
  • Test Leads (Red and Black)
  • Operator's Instruction Manual
  • Carrying Case (optional, if included with your purchase)
Brother HD-390A Analog Multimeter with carrying case and test leads

Figure 1: Multimeter with optional carrying case and test leads.

Video 1: Unboxing the Brother HD-390A Analog Multimeter, showing the multimeter, manual, and test leads.

4. Product Overview

The HD-390A features a clear analog display, a rotary switch for function and range selection, and input jacks for test leads.

4.1 Front Panel

Front view of Brother HD-390A Analog Multimeter

Figure 2: Front view of the HD-390A Multimeter.

  • Analog Display: Shows measurement readings via a pointer.
  • Rotary Switch: Used to select measurement functions (DCV, ACV, DCmA, Resistance, etc.) and ranges.
  • Input Jacks:
    • VmAΩ+: Positive input for voltage, current, and resistance measurements.
    • COM: Common (negative) input for all measurements.
    • +10A: Dedicated input for high DC current measurements (up to 10A).
  • 0Ω ADJ: Knob for adjusting the zero-ohm reading for resistance measurements.
  • Transistor/Diode/LED Test Socket: For testing transistors (NPN/PNP), diodes, and LEDs.

4.2 Rear Panel

Back view of Brother HD-390A Analog Multimeter showing battery cover

Figure 3: Back view of the HD-390A Multimeter with battery cover.

  • Battery Cover: Provides access for battery installation and replacement.
  • Tilt Stand: Allows the multimeter to be propped up for easier viewing.

5. Setup

5.1 Battery Installation

The HD-390A requires two 1.5V AAA batteries (R03P) and one 9V battery (6F22/NEDA1604). Batteries are not included with the device.

  1. Ensure the multimeter is turned OFF.
  2. Locate the battery cover on the rear panel (Figure 3).
  3. Slide or pull down the battery cover as indicated by the arrows.
  4. Insert the two 1.5V AAA batteries and one 9V battery, observing the correct polarity (+/-).
  5. Replace the battery cover and ensure it is securely latched.

5.2 Connecting Test Leads

Connect the red test lead to the VmAΩ+ jack and the black test lead to the COM jack for most measurements. For high DC current measurements (up to 10A), connect the red test lead to the +10A jack and the black test lead to the COM jack.

Brother HD-390A Multimeter with test leads connected

Figure 4: Multimeter with test leads connected.

6. Operating Instructions

The HD-390A operates in manual range mode. Always select the appropriate function and range before making a measurement.

6.1 General Measurement Procedure

  1. Turn the rotary switch to the desired measurement function (e.g., DCV, ACV, Ω).
  2. Select an appropriate range. If unsure, start with the highest range and decrease it until a suitable reading is obtained.
  3. Connect the test leads to the circuit or component being measured.
  4. Read the value indicated by the pointer on the analog scale.
  5. When finished, turn the rotary switch to the OFF position.

6.2 Specific Measurement Functions

6.2.1 DC Voltage (DCV) Measurement

  • Set the rotary switch to the desired DCV range (0.1V, 2.5V, 10V, 50V, 250V, 1000V).
  • Connect the red test lead to the positive side and the black test lead to the negative side of the DC voltage source.
  • Read the DCV scale.

6.2.2 AC Voltage (ACV) Measurement

  • Set the rotary switch to the desired ACV range (10V, 50V, 250V, 1000V).
  • Connect the test leads across the AC voltage source.
  • Read the ACV scale.

6.2.3 DC Current (DCmA) Measurement

  • Set the rotary switch to the desired DCmA range (50uA, 2.5mA, 25mA, 250mA, 10A).
  • For 10A range, connect the red test lead to the +10A jack. For other ranges, use the VmAΩ+ jack.
  • Connect the multimeter in series with the circuit.
  • Read the DCmA scale.

6.2.4 Resistance (Ω) Measurement

  • Set the rotary switch to the desired Ω range (X1, X10, X100, X1K, X10K, X100K).
  • Before measuring, short the test leads together and adjust the 0Ω ADJ knob until the pointer reads zero on the resistance scale.
  • Connect the test leads across the component to be measured.
  • Read the Ω scale and multiply by the selected range multiplier.

6.2.5 Capacitance (uF) Measurement

  • Set the rotary switch to the Capacitance (uF) range.
  • Use the accessory kit (if provided) and R x 1K range for measurement.
  • Connect the test leads to the capacitor.
  • Read the capacitance value.

6.2.6 Battery (BATT) Check

  • Set the rotary switch to the BATT range (1.5V or 9V).
  • Connect the test leads to the battery, observing polarity.
  • Read the BATT scale to determine if the battery is GOOD, ?, or BAD.

6.2.7 Transistor Check (hFE)

  • Set the rotary switch to the hFE range.
  • Insert the transistor (NPN or PNP) into the special hFE socket, ensuring correct pin alignment (E, B, C).
  • Read the hFE value.

6.2.8 LED, Diode Check

  • Set the rotary switch to the LED, Diode Check range (via special hFE socket).
  • Insert the LED or diode into the appropriate socket.
  • Observe the reading or LED illumination.

6.2.9 Decibel (dB) Measurement

  • Decibel measurements are performed at ACV ranges.
  • Set the rotary switch to an ACV range.
  • Connect the test leads to the circuit.
  • Read the dB scale.

6.2.10 Continuity Check

  • Set the rotary switch to the Continuity Check range (at Rx1).
  • Connect the test leads across the component or circuit path.
  • A beeper will sound if the resistance is under 200 Ohms, indicating continuity.

7. Specifications

7.1 General Specifications

  • Operating Mode: Manual Range
  • DIY Supplies: Electrical
  • Certification: CE
  • Origin: Mainland China
  • Battery Included: No
  • High-concerned chemical: None
  • Standard Environmental Conditions: 23°C ± 5°C, humidity <75% RH
  • Working Environment Range: 0°C ~ 40°C, humidity <90% RH
  • Dimensions: 160mm x 105mm x 40mm
  • Power Source: Internal Battery: R03P, AAA, 1.5Vx2pcs; 6F22, NEDA1604, 9Vx1pc

7.2 Measurement Specifications

Table of specifications for DC V, AC V, and DC mA

Figure 5: Measurement specifications for Voltage and Current.

Table 1: Voltage and Current Measurement Specifications
Test FunctionsRangeAccuracyRemarks
DC V0-0.1-2.5-10-50-250 V
-1000 V
± 3% FSD.
± 4% FSD. For 1000V
Input Impedance: 20KΩ/V
Overload Protection: Max. 1000V AC/DC BUT 0.1V/2.5V/10V 250V Max.
AC V0-10-50-250V
-1000V
± 4% FSD.
± 5% FSD. For 1000V
Input Impedance: 9KΩ/V
Overload Protection: Max. 1000V AC/DC But 10V/50V only 250V Max.
Band width: 40 ~ 10K Hz
DC mA0-0.05-2.5-25-250 mA,
10A
± 3% FSD.
± 4% FSD. For 10A
Drop Voltage: 250 mV
Overload protected by Fuses 0.5A/250V & 10A/250V at 10A range, and Oxide Varactor<250V AC/DC(5s). Max. testing time 1 min. for 10A.
Table of specifications for Resistance, Capacitance, Battery Check, Transistor Check, LED/Diode Check, Decibel, Continuity Check, and Power Source

Figure 6: Measurement specifications for Resistance and other functions.

Table 2: Resistance and Other Measurement Specifications
Test FunctionsRangeAccuracyRemarks
ΩX 1: 0.2 ~ 2KΩ Midscale at 20Ω
X 10: 2 ~ 20KΩ Midscale at 200Ω
X 100: 20 ~ 200KΩ Midscale at 2000Ω
X1K: 200 ~ 2MΩ Midscale at 20KΩ
X10K: 2K ~ 20MΩ Midscale at 200KΩ
X100K: 20K ~ 200MΩ Midscale at 2MΩ
± 4% of ARC of Scale LengthOverload protected by the Oxide Varactor & Fuse <250V AC/DC(5s).
Capacitance (uF)0.025-0.25-25uF(C2),
2000uF(C1)
± 3% FSD.
Approximate Value
Use the Accessory Kit use the R x 1K range
BATT Check0 ~ 1.5V: GOOD - ? - BAD
0 ~ 9V: GOOD - ? - BAD
± 5% of ARC of Scale LengthLoad Current: 270mA for 1.5V
25mA for 9V
Overload protected by Fuse & Oxide Varactor.<250V AC/DC(5s).
Transistor CheckhFE: 0-1000 via special hFe socketApproximate ValueAt Ω X 10 Range
LED, Diode Checkvia special hFe socketApproximate ValueAt Ω X 10 Range
Decibel-22 dB ~ +62 dB (0dB=1mW at 600Ω)Approximate ValueAt ACV ranges
Continuity CheckAt Rx1Beeper sounding under 200 Ohm

8. Maintenance

8.1 Cleaning

Wipe the multimeter with a damp cloth and mild detergent. Do not use abrasives or solvents. Ensure the device is dry before storage or use.

8.2 Battery Replacement

Replace batteries as described in Section 5.1 when the display becomes dim or readings are inaccurate. Always dispose of old batteries responsibly.

8.3 Storage

When not in use for extended periods, remove the batteries to prevent leakage. Store the multimeter in a cool, dry place, away from direct sunlight and extreme temperatures.

9. Troubleshooting

  • No Reading/Dim Display: Check battery levels and replace if necessary. Ensure test leads are properly connected.
  • Inaccurate Readings: Verify the correct function and range are selected. For resistance measurements, ensure the 0Ω ADJ knob is calibrated. Check for damaged test leads.
  • No Continuity Beep: Ensure the multimeter is set to the continuity range (Rx1) and the resistance is below 200 Ohms.
  • Overload Protection: If an overload occurs, the multimeter's internal protection mechanisms (fuses, varactor) will activate. Disconnect from the circuit immediately and check for blown fuses (if accessible and user-replaceable according to safety guidelines).

10. User Tips

No specific user tips were found in the provided customer reviews or Q&A data that are not already covered in the main instructions.

11. Warranty and Support

For warranty information or technical support, please refer to the documentation provided with your purchase or contact the retailer/manufacturer directly. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.