1. Introduction
The ELECTESLA ES-P300 Pressure Transmitter is a high-precision device designed for measuring pressure in various mediums including liquid, gas, steam, and oil. It offers multiple output signals and pressure connection options, making it versatile for a wide range of industrial applications. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your ES-P300 Pressure Transmitter.

This image displays the ES-P300 Pressure Transmitter, highlighting its input range of -0.1 to 100Mpa, output options of 4-20mA, 0-5V/10V, RS485, and a power requirement of DC24V.
2. Product Overview
The ES-P300 Pressure Transmitter is engineered for durability and accuracy, featuring a robust stainless steel housing and advanced internal components. Its design ensures strong anti-interference capabilities and long-term stability.
2.1 Key Components and Features
- Housing Material: SS304, SS316 anti-corrosive stainless steel.
- Diffusion Silicon Chip: Imported, providing 8ms instantaneous response.
- High Strength Adhesive Design: Ensures high pressure resistance and leak-proof performance.
- Pure Copper Core: High melting point, high temperature resistant.
- PVE Engineer Plastic: Flame retardant and pressure resistant.
- High Precision Core Body: 0.2%FS high precision with strong anti-interference.
- Anti-Damping Design: Resistant to 300% instantaneous impact.
- Digital Circuit Board: Enhances anti-interference for stable and accurate measurements.
- Standardized Production Process: Enclosed with silicone gel for waterproof and moisture-proof protection, ensuring long component life.
- Laser Printed Labels: Product parameters are laser-printed on the shell for easy data access and customization.

This diagram shows the internal structure of the ES-P300, detailing components like the SS304/SS316 material, imported diffusion silicon chip, high strength adhesive, PVE engineer plastic, pure copper core, and anti-damping design.

This image highlights the digital circuit board inside the transmitter, which is crucial for enhancing anti-interference and ensuring measurement stability and accuracy.

This image illustrates the infusion of silicone gel during the production process, which makes the product waterproof and moisture-proof, extending the service life of its components.

This image details the damping design, featuring a 3mm damped pilot hole that safely draws out pressure, preventing instantaneous overload damage and extending sensor life.

This image shows the laser-printed product parameters on the transmitter's shell, allowing for easy access to data and customization with company names or logos.
3. Specifications
The ES-P300 Pressure Transmitter is available with various configurations to suit specific application needs. Refer to the tables below for detailed technical parameters, measuring ranges, and thread sizes.
3.1 Technical Parameters
| Parameter | Description |
|---|---|
| Product Name | Pressure Transmitter |
| Measured Medium | Liquid, gas, vacuum, oil, etc. |
| Accuracy Level | 0.1%, 0.25% (default) |
| Stability | 0.1% F.S |
| Measurement Range | -100KPa ~ +100Mpa (interval optional) |
| Output Signal | 4-20mA (default), 0-10V, 0-5V, RS485, HART |
| Power Supply Voltage | 9-36VDC (default), 5VDC, 3.3VDC |
| Communication Output | RS485, 4-20mA+HART |
| Installation Interface | M20*1.5 (default), G1/4, G1/2, etc. |
| Operating Temperature | -20 ~ +70℃ |
| Storage Temperature | -40 ~ +120℃ |
| Overload Limit | 1.5 times rated range (can be customized higher) |
| Load Resistance | ≤600Ω |
| Isolation Diaphragm | 316L stainless steel |
| Protection Class | IP65 |

This image provides a comprehensive table of technical specifications for the ES-P300 Pressure Transmitter, including measured medium, accuracy, output signal, power supply, and operating conditions.
3.2 Measuring Range and Thread Size

This image presents tables for confirming pressure ranges (from -100KPa to 60Mpa) and available thread sizes (e.g., M20x1.5, G1/4, NPT1/4).
4. Installation & Setup
Proper installation and wiring are crucial for the accurate and safe operation of the ES-P300 Pressure Transmitter. Ensure all connections are secure and appropriate for your application.
4.1 Wiring Instructions
The ES-P300 Pressure Transmitter typically uses a multi-core cable for electrical connection. Refer to the product label and the video below for specific wiring details based on your chosen output signal (4-20mA, 0-5V/10V, RS485).
This video demonstrates the wiring process for a Herschman Pressure Transmitter, showing the connection of the multi-colored wires (blue, red, yellow, green) to the sensor. It also highlights the various thread types available.
4.2 Pressure Connection
Select the appropriate pressure connection thread (e.g., M20x1.5, G1/2, G1/4, NPT1/4) that matches your system. Ensure a tight and leak-free connection to prevent measurement inaccuracies or system failures.
5. Operation
Once installed and wired correctly, the ES-P300 Pressure Transmitter operates continuously to provide accurate pressure readings. Ensure the power supply voltage is within the specified range (9-36VDC, 5VDC, or 3.3VDC depending on configuration) for optimal performance.
6. Maintenance
The ES-P300 Pressure Transmitter is designed for long-term reliability with minimal maintenance. However, periodic checks can help ensure continued accuracy and extend its lifespan.
- Regular Cleaning: Keep the exterior of the transmitter clean, especially the pressure connection area, to prevent buildup that could affect performance.
- Connection Integrity: Periodically check all electrical and pressure connections for tightness and signs of wear or corrosion.
- Environmental Conditions: Ensure the operating environment remains within the specified temperature range (-20 to +70℃) and avoid exposure to harsh chemicals unless the unit is specifically rated for them.
- Calibration Check: For critical applications, periodic calibration checks are recommended to verify accuracy.
7. Troubleshooting
If you encounter issues with your ES-P300 Pressure Transmitter, refer to the following common problems and their potential solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| No Output/Incorrect Reading | Incorrect wiring, no power, sensor damage, incorrect range selection. | Verify wiring according to diagram. Check power supply. Ensure sensor is not physically damaged. Confirm selected measuring range matches application. |
| Unstable Output | Electrical interference, unstable power supply, vibration, air bubbles in medium. | Check for proper grounding and shielding. Ensure stable power. Isolate from vibration sources. Purge air from the system. |
| Leakage at Connection | Improper thread sealant, loose connection, damaged thread. | Reapply thread sealant (e.g., PTFE tape). Tighten connection. Inspect threads for damage and replace if necessary. |
| Sensor Not Responding | Sensor clogged, internal failure. | Check for blockages in the pressure port. If problem persists, contact support. |
8. User Tips
While no specific user tips were available from reviews or Q&A, general best practices for pressure transmitters include:
- Always ensure the pressure range of the transmitter matches or exceeds the maximum expected pressure in your application to prevent damage.
- Use appropriate thread sealants (e.g., PTFE tape or liquid sealant) to ensure leak-free connections.
- Protect the electrical connections from moisture and physical damage.
- Consider the operating temperature and chemical compatibility of the wetted parts with your measured medium.
9. Warranty & Support
The ELECTESLA ES-P300 Pressure Transmitter comes with a 24-month warranty from the date of purchase, covering manufacturing defects. For technical support, warranty claims, or any inquiries, please contact ELECTESLA Official Store customer service.