1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of your DIANQI Single Phase LCD Digital Display DIN Rail Electric Energy Meter. These meters are designed for measuring active energy consumption in single-phase AC circuits. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.

2. Safety Information
- Installation should only be performed by qualified personnel.
- Ensure power is disconnected before any installation or wiring work.
- Do not operate the meter if it is damaged or shows signs of malfunction.
- Observe all local electrical codes and regulations.
- The meter is designed for indoor use in a dry environment.
3. Specifications
| Feature | Specification |
|---|---|
| Brand Name | DIANQI |
| Model Number | DDS1108 (also DDS662, DDS667, DDS668 variants) |
| Rated Voltage | 230V AC |
| Frequency | 60Hz |
| Max Operating Current | 5(60)A or 5(80)A (model dependent) |
| Pulse Frequency | 1000imp / kWh |
| Display Type | LCD Digital (with Backlight on most models) |
| Phase | Single Phase |
| Installation | 35mm DIN Rail |
| Certification | CE |
Dimensions
- DDS1108: Approximately 36.5mm (W) x 78.5mm (H) x 66mm (D).

Figure 2: DDS1108 Dimensions - DDS662: Approximately 36.5mm (W) x 78.5mm (H) x 43mm (D).

Figure 3: DDS662 Dimensions - DDS667: Approximately 36mm (W) x 78.4mm (H) x 65.6mm (D).

Figure 4: DDS667 Dimensions - DDS668: Approximately 36mm (W) x 78.3mm (H) x 65.6mm (D).

Figure 5: DDS668 Dimensions
4. Package Contents
- 1 x DIANQI Electric Energy Meter (selected model)
5. Setup and Installation
The energy meter is designed for 35mm DIN rail installation. Ensure the mounting location is dry, stable, and free from excessive vibration or direct sunlight.
Wiring Instructions
The wiring method for all models is typically 'upper input and lower output'. Always connect the Live (L) and Neutral (N) wires correctly as indicated on the meter and in the diagrams below. It is recommended to install a circuit breaker upstream of the energy meter for safety and protection.



Important: Always ensure correct polarity (Live and Neutral) and secure connections to prevent electrical hazards and ensure accurate readings.
6. Operating Instructions
Once correctly installed and powered on, the meter will begin displaying readings. The pulse LED will flash to indicate active energy measurement.
Display Functions
The meters are designed to display various parameters. The specific parameters and how they are displayed vary by model:
- DDS1108 & DDS662: These models typically cycle through or allow manual selection of total Energy (kWh), temporary Energy (kWh), real Voltage, real Current, and real Power.
- DDS667 & DDS668: These models offer similar displays, often including additional parameters like frequency and power factor. The DDS668 model specifically displays two values simultaneously, with one always being power.




Resetting Temporary kWh
- For DDS1108 and DDS662: The temporary kWh value on these models cannot be reset to zero. The total kWh value is also non-resettable.
- For DDS667 and DDS668: These models feature a reset button. To reset the temporary kWh, press and hold the button for approximately 6 seconds. The total kWh value remains non-resettable.
Operation Demonstration Video
7. Maintenance
The energy meter requires minimal maintenance. Keep the device clean and free from dust and moisture. Do not use abrasive cleaners or solvents. Periodically check the wiring connections to ensure they remain secure.
8. Troubleshooting
- No Display: Check the power supply and ensure all wiring connections are secure. Verify the circuit breaker is on.
- Incorrect Readings: Double-check the wiring according to the diagrams. Ensure the meter is installed correctly for single-phase measurement.
- Pulse LED Not Flashing: Verify that there is a load connected and drawing power. Check wiring.
If issues persist after checking these points, please contact a qualified electrician or the manufacturer for assistance.
9. User Tips
- For long-term energy monitoring, note that the total kWh cannot be reset on any model. Use the temporary kWh function (if available on your model) for shorter-term measurements.
- The backlight feature (if present) enhances readability in low-light conditions.
10. Warranty and Support
For warranty information or technical support, please refer to the documentation provided at the time of purchase or contact your vendor. Keep your purchase receipt as proof of purchase.