1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your DIANQI Single Phase LCD Digital Display DIN Rail Electric Energy Meter. These meters are designed for measuring active energy consumption in single-phase AC circuits. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.

Overview of DIANQI energy meters, showing DDS662, DDS1108 (unresettable) and DDS667, DDS668 (resettable) models.
Figure 1: Overview of DIANQI Electric Energy Meter Models

2. Safety Information

  • Installation should only be performed by qualified personnel.
  • Ensure power is disconnected before any installation or wiring work.
  • Do not operate the meter if it is damaged or shows signs of malfunction.
  • Observe all local electrical codes and regulations.
  • The meter is designed for indoor use in a dry environment.

3. Specifications

FeatureSpecification
Brand NameDIANQI
Model NumberDDS1108 (also DDS662, DDS667, DDS668 variants)
Rated Voltage230V AC
Frequency60Hz
Max Operating Current5(60)A or 5(80)A (model dependent)
Pulse Frequency1000imp / kWh
Display TypeLCD Digital (with Backlight on most models)
PhaseSingle Phase
Installation35mm DIN Rail
CertificationCE

Dimensions

  • DDS1108: Approximately 36.5mm (W) x 78.5mm (H) x 66mm (D).
    Dimensions for DDS1108 model.
    Figure 2: DDS1108 Dimensions
  • DDS662: Approximately 36.5mm (W) x 78.5mm (H) x 43mm (D).
    Dimensions for DDS662 model.
    Figure 3: DDS662 Dimensions
  • DDS667: Approximately 36mm (W) x 78.4mm (H) x 65.6mm (D).
    Dimensions for DDS667 model.
    Figure 4: DDS667 Dimensions
  • DDS668: Approximately 36mm (W) x 78.3mm (H) x 65.6mm (D).
    Dimensions for DDS668 model.
    Figure 5: DDS668 Dimensions

4. Package Contents

  • 1 x DIANQI Electric Energy Meter (selected model)

5. Setup and Installation

The energy meter is designed for 35mm DIN rail installation. Ensure the mounting location is dry, stable, and free from excessive vibration or direct sunlight.

Wiring Instructions

The wiring method for all models is typically 'upper input and lower output'. Always connect the Live (L) and Neutral (N) wires correctly as indicated on the meter and in the diagrams below. It is recommended to install a circuit breaker upstream of the energy meter for safety and protection.

Wiring diagram for DDS668 model, showing connections to a power switch and air circuit breaker.
Figure 6: DDS668 Wiring Diagram (Example)
Wiring diagram for DDS667 model, showing connections to a power switch and air circuit breaker.
Figure 7: DDS667 Wiring Diagram (Example)
Wiring diagram for DDS662 model, showing connections to a power switch and air circuit breaker.
Figure 8: DDS662 Wiring Diagram (Example)

Important: Always ensure correct polarity (Live and Neutral) and secure connections to prevent electrical hazards and ensure accurate readings.

6. Operating Instructions

Once correctly installed and powered on, the meter will begin displaying readings. The pulse LED will flash to indicate active energy measurement.

Display Functions

The meters are designed to display various parameters. The specific parameters and how they are displayed vary by model:

  • DDS1108 & DDS662: These models typically cycle through or allow manual selection of total Energy (kWh), temporary Energy (kWh), real Voltage, real Current, and real Power.
  • DDS667 & DDS668: These models offer similar displays, often including additional parameters like frequency and power factor. The DDS668 model specifically displays two values simultaneously, with one always being power.
DDS1108 model with display showing kWh.
Figure 9: DDS1108 Display
DDS662 model with display showing kWh, Voltage, Current, Power.
Figure 10: DDS662 Display
DDS667 model with display showing Power, Current, Voltage, kWh.
Figure 11: DDS667 Display
DDS668 model with display showing various parameters like kWh, Power, Voltage, Frequency, Current, Power Factor.
Figure 12: DDS668 Display

Resetting Temporary kWh

  • For DDS1108 and DDS662: The temporary kWh value on these models cannot be reset to zero. The total kWh value is also non-resettable.
  • For DDS667 and DDS668: These models feature a reset button. To reset the temporary kWh, press and hold the button for approximately 6 seconds. The total kWh value remains non-resettable.

Operation Demonstration Video

Video 1: Demonstration of DDS1108 energy meters connected to a circuit breaker, showing power-on and display functionality.

7. Maintenance

The energy meter requires minimal maintenance. Keep the device clean and free from dust and moisture. Do not use abrasive cleaners or solvents. Periodically check the wiring connections to ensure they remain secure.

8. Troubleshooting

  • No Display: Check the power supply and ensure all wiring connections are secure. Verify the circuit breaker is on.
  • Incorrect Readings: Double-check the wiring according to the diagrams. Ensure the meter is installed correctly for single-phase measurement.
  • Pulse LED Not Flashing: Verify that there is a load connected and drawing power. Check wiring.

If issues persist after checking these points, please contact a qualified electrician or the manufacturer for assistance.

9. User Tips

  • For long-term energy monitoring, note that the total kWh cannot be reset on any model. Use the temporary kWh function (if available on your model) for shorter-term measurements.
  • The backlight feature (if present) enhances readability in low-light conditions.

10. Warranty and Support

For warranty information or technical support, please refer to the documentation provided at the time of purchase or contact your vendor. Keep your purchase receipt as proof of purchase.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.