GEYA GSR2-1 SSR

Contents

GEYA GSR2-1 Series Solid State Relay with Heat Sink

User Instruction Manual

1. Introduction

The GEYA GSR2-1 series Solid State Relay (SSR) with integrated heat sink is designed for reliable and efficient switching of electrical loads. This series offers various control types, including DC control AC, DC control DC, and AC control AC, with current ratings ranging from 10A to 120A. Its compact design allows for both screw fixing and DIN rail mounting, making it suitable for a wide range of industrial automation and home appliance applications.

GEYA GSR2-1 Solid State Relays with Heat Sinks mounted on a DIN rail
Figure 1: GEYA GSR2-1 Solid State Relays with Heat Sinks

2. Key Features

  • Built-in TVS: Integrated Transient Voltage Suppressor (TVS) for enhanced triac protection.
  • LED Indicator: Provides visual status of the relay's operation.
  • Zero-cross or Random Turn-on: Default is zero-cross SSR, with random turn-on available for customization.
  • Integrated Heat Sink: Efficient heat dissipation for stable performance.
  • Multiple Control Types: Available in DC to AC, DC to DC, and AC to AC configurations.
  • Wide Current Range: Supports load currents from 10A up to 120A.
  • Versatile Mounting: Can be fixed with screws or mounted on a DIN rail.
Various views of the GEYA Solid State Relay with integrated heat sink
Figure 2: GEYA GSR2-1 SSR with Heat Sink (various views)

3. Specifications

Table 1: General Specifications for GEYA GSR2-1 SSR
AttributeValue
Brand NameGEYA
Model NumberSSR with Radiator
TheoryTime Relay
Power SourceDC
FunctionDC control AC, AC control AC, DC control DC
Load Current10A, 25A, 40A, 60A, 80A, 100A, 120A
Control Voltage3-32VDC
Load Voltage24-480VAC
Control CurrentDC5mA-25mA
Must Operation Voltage2.8VDC
Must Release Voltage1.5VDC
Peak Voltage800V
On Voltageless than 1.5V
Off Leakage Currentless than 5mA
On-off Timeless than 10ms
Dielectric StrengthInput - output - floor more than 2500VAC
Ambient Temperature-25°C to +75°C
CertificationCE
Dimensions for various GSR2-1DA models (10A, 25A, 40A, 60A, 80A, 100A)
Figure 3: Dimensions for GSR2-1DA models (10A to 100A)

4. Installation

The GEYA GSR2-1 SSR can be installed using two primary methods: screw fixing or DIN rail mounting.

  1. Fix with Screws: Secure the relay to a flat surface using appropriate screws through the designated mounting holes.
  2. DIN Rail Mounted: Attach the relay to a standard DIN rail by snapping it into place. Ensure it is firmly seated.
Diagram showing two installation methods: fixing with screws and DIN rail mounting
Figure 4: Installation Methods (Screw Fixing and DIN Rail Mounting)

5. Wiring Example (DC Control AC)

Follow the wiring diagram carefully to ensure correct and safe operation. This example illustrates a DC control AC configuration, commonly used for heating applications.

Wiring diagram for DC control AC SSR, showing input from DC Power Supply and output to AC Power Supply and Heating Pipe
Figure 5: DC Control AC Wiring Example

Wiring Steps:

  1. Connect the AC Power Supply (24-480VAC) to the OUTPUT terminals (1 and 2) of the SSR. Terminal 1 is typically 'L' (Live) and Terminal 2 is 'N' (Neutral).
  2. Connect the Heating Pipe (load) across the OUTPUT terminals (1 and 2).
  3. Connect the DC Power Supply (3-32VDC) to the CONTROL terminals (3 and 4) of the SSR. Terminal 3 is '+' and Terminal 4 is '-'.

Important Note:

In the off state, due to the influence of the built-in capacitor of the product, it is not applicable for special scenarios with off-state leakage current ≤ 5MA. Please purchase with caution if your application requires extremely low off-state leakage current.

6. Operation

The GEYA GSR2-1 SSR operates by applying a control voltage to its input terminals. When the control voltage is applied (within the specified range of 3-32VDC for DC control models), the internal semiconductor switch turns on, allowing current to flow through the load. When the control voltage is removed, the switch turns off, interrupting the current to the load.

  • LED Indicator: Observe the built-in LED indicator. It illuminates when the control voltage is applied and the SSR is in the ON state.
  • Zero-Cross Switching: Most standard GSR2-1 SSRs feature zero-cross switching, meaning the output turns on or off when the AC load voltage crosses zero. This minimizes electrical noise and extends the life of the load.

7. Maintenance

To ensure optimal performance and longevity of your GEYA GSR2-1 SSR, follow these maintenance guidelines:

  • Regular Inspection: Periodically check the SSR and its connections for any signs of damage, loose wiring, or overheating.
  • Cleanliness: Keep the SSR and its heat sink free from dust and debris to maintain efficient heat dissipation. Use a soft, dry cloth for cleaning.
  • Thermal Management: Ensure adequate airflow around the SSR, especially if it's operating near its maximum current rating. Verify that the heat sink is not obstructed.
  • Tighten Connections: Periodically re-tighten terminal screws to prevent loose connections, which can lead to overheating or intermittent operation.
  • Avoid Overloading: Do not exceed the specified load current or voltage ratings to prevent damage to the SSR.

8. Troubleshooting

If you encounter issues with your GEYA GSR2-1 SSR, consider the following:

  • SSR Not Turning On:
    - Check if the control voltage is applied correctly and is within the specified range (3-32VDC).
    - Verify that the load is connected properly and is not open-circuited.
    - Inspect the LED indicator; if it's not lit when control voltage is present, the SSR might be faulty.
  • SSR Not Turning Off (Load Remains On):
    - Ensure the control voltage is completely removed. Residual voltage can keep the SSR in the ON state.
    - Check for short circuits in the load or wiring.
    - Off-state Leakage Current: As noted in the precautions, the built-in capacitor can cause a small off-state leakage current. If your application is sensitive to leakage current ≤ 5mA, this SSR may not be suitable.
  • Overheating:
    - Ensure the load current does not exceed the SSR's rating.
    - Verify that the heat sink is clean and has adequate ventilation.
    - Confirm that thermal grease was applied correctly between the SSR and any external heat sink (if applicable).
  • Intermittent Operation:
    - Check all wiring connections for tightness and proper contact.
    - Ensure the control signal is stable and free from noise.

9. User Tips

  • Inductive Loads: When using the SSR with inductive loads (e.g., motors, transformers), ensure the SSR's current rating is sufficiently oversized to handle inrush currents and voltage spikes. Consider adding external snubber circuits if necessary for highly inductive loads.
  • Proper Heat Sinking: Always use a heat sink appropriate for the load current and ambient temperature. Insufficient heat sinking is a common cause of SSR failure.
  • Control Signal Quality: Provide a clean and stable control signal to the SSR for reliable switching. Avoid noisy environments or fluctuating control voltages.

10. Frequently Asked Questions (FAQ)

Q: How much of an inductive load can this SSR handle?
A: The amount of inductive load an SSR can handle depends on its current rating and the specific characteristics of the load (e.g., inrush current, power factor). It is generally recommended to derate SSRs for inductive loads, often by 50% or more, to account for higher peak currents and voltage transients. Always consult the SSR's datasheet and consider the load's specifications.

11. Additional Documents

For more detailed technical information, diagrams, and product certifications, please refer to the official user manual PDF available from the manufacturer. A link to the PDF is provided by the seller: GEYA GSR2-1 User Manual (PDF).

12. Warranty and Support

For warranty information, technical support, or any product-related inquiries, please contact GEYA Electricals Store directly. Refer to your purchase documentation for specific contact details.