1. Introduction

The JUNCTEK JDS6600 series Dual-channel DDS Signal Generator is a versatile instrument combining multiple functions including Function Signal Generator, Arbitrary Waveform Generator, Pulse Generator, Sweep, Counter, and Frequency Meter. Utilizing Direct Digital Synthesizer (DDS) technology, it delivers stable, precise, pure, and low-distortion signals. This instrument is an essential tool for electronics engineers, electronic laboratories, and educational or research institutions.

The JDS6600 series is available in various models, primarily differing in their maximum sine wave output frequency, ranging up to 60MHz. It features a 2.4-inch TFT color LCD display that simultaneously shows parameters for both channels (CH1 and CH2).

1.1. Package Contents

Upon receiving your JDS6600 Signal Generator, please verify that all accessories are included and in good condition. If any items are missing or damaged, contact your dealer or the manufacturer immediately.

  • 1 x JDS6600 DDS Signal Generator
  • 1 x CD (Software and drivers)
  • 1 x Power Adapter
  • 1 x USB Data Cable
  • 1 x BNC-BNC Cable
  • 2 x BNC-Clip Cables
  • 1 x Instruction Manual (PDF)
JDS6600 Signal Generator and included accessories
JDS6600 Signal Generator with included accessories.

2. Safety Information

Always operate the JDS6600 in a safe environment. Ensure proper ventilation and avoid exposing the device to moisture, extreme temperatures, or direct sunlight. Do not attempt to open or repair the device yourself, as this may void the warranty and pose a safety risk. Use only the provided power adapter and cables.

3. Product Overview

3.1. Front Panel

Front view of JDS6600 Signal Generator with labels
Front panel of the JDS6600 Signal Generator.
  • LCD Display: 2.4-inch TFT color screen for displaying parameters and waveforms.
  • Power Button: Turns the device on/off.
  • Function Softkeys: Activates corresponding functions displayed on the screen.
  • Function Shortcut Keys: Dedicated buttons for WAVE, MOD, SYS, MEAS.
  • OK Button: Confirms selections and controls simultaneous output of CH1 and CH2.
  • CH1/CH2 Buttons: Selects the active channel; long press sets the channel as main display.
  • Shuttle Knob: For continuous adjustment of parameters.
  • Swinging Strut: Allows for adjustable viewing angle.
  • Ext. IN: External input for measurement functions.
  • CH1/CH2 Output: BNC interfaces for Channel 1 and Channel 2 signal output.

3.2. Rear Panel

Rear view of JDS6600 Signal Generator with labels
Rear panel of the JDS6600 Signal Generator.
  • TTL Extension Interface: For user secondary development with TTL level mode serial interface.
  • USB Interface: For PC communication and arbitrary waveform drawing.
  • DC5V Supply Socket: Power input (DC 5V).

3.3. Display Interface

Screenshot of JDS6600 main display interface
Main display interface showing CH1 and CH2 parameters.
  • CH1/CH2 Parameter Display: Shows current settings for each channel (e.g., frequency, amplitude, offset, duty cycle).
  • Waveform Display: Visual representation of the output waveform.
  • Current Channel Output Status: Indicates if a channel is active.
  • Soft-key Menu Bar: Context-sensitive options for the current screen.
  • Phase Difference: Displays the phase relationship between CH1 and CH2.

4. Specifications

4.1. Frequency Characteristics (JDS6600-15M Model)

ParameterRange
Sine wave frequency range0~15MHz
Square wave frequency range0~15MHz
Triangle wave frequency range0~15MHz
Pulse frequency range0~6MHz
TTL digital frequency range0~6MHz
Arbitrary wave frequency range0~6MHz
Pulse width adjustment range100nS - 4000S
Square wave rise time≤25ns
Minimum frequency resolution0.01uHz (0.00000001Hz)
Frequency accuracy±20ppm
Frequency stability±1ppm/3hours

4.2. Waveform Specifications

ParameterValue
Waveform typesSine, Square, Pulse (adjustable duty cycle, precise adjustment of pulse width and period), Triangular, Partial Sine, CMOS, DC level, Half-wave, Full-wave, Pos-ladder, Neg-ladder, Noise, Exponential Rise, Exponential Fall, Tone, Cink Pulse, Lorentz Pulse, and 60 user-defined arbitrary waveforms.
Waveform length2048 points
Waveform sampling rate266 MSa/s
Waveform vertical resolution14 bits
Sine wave harmonic suppression≥45dBc(<1MHz); ≥40dBc(1MHz~20MHz)
Total harmonic distortion<1%(20Hz~20kHz,0dBm)
Square and Pulse wave overshoot≤5%
Pulse and Partial sine wave duty-cycle adjustment range0.1 - 99.9%
Sawtooth wave linearity≥98%(0.01 Hz~10 kHz)

4.3. Output Specifications

ParameterValue
Sine wave amplitude range (≤10MHz)2mVpp~20Vpp
Sine wave amplitude range (10MHz~30MHz)2mVpp~10Vpp
Sine wave amplitude range (>30MHz)2mVpp~5Vpp
Square/Triangle wave amplitude range (≤10MHz)2mVpp~20Vpp
Square/Triangle wave amplitude range (10MHz~25MHz)2mVpp~5Vpp
Amplitude resolution1 mV
Amplitude stability±0.5%/5 hours
Amplitude flatness±5%(<10MHz); ±10%(>10MHz)
Output impedance50Ω±10% (typical)
ProtectionAll signal outputs can work within 60s when the load is short-circuited.

4.4. DC Offset

Output AmplitudeOffset Adjustment Range
>2V-9.99V~9.99V
0.2V < Output Range ≤ 2V-2.5V~2.5V
0 < Output Amplitude ≤ 0.2V-0.25V~0.25V
Offset resolution0.01 V

4.5. Phase Characteristics

ParameterValue
Phase adjusting range0 ~ 359.9°
Phase resolution0.1°

4.6. TTL/CMOS Output

ParameterValue
Low level<0.3V
High level1V~10V
Level rise/fall time≤20ns

4.7. External Measurement Function

FunctionParameterValue
Frequency MeterFrequency measurement range1Hz~100MHz
Measurement accuracyGate time continuously adjusted between 0.01S~10s
Counter FunctionCounting range0-4294967295
Coupled modeDC and AC coupling methods
Counting methodManual operation
Input signal voltage range2Vpp~20Vpp
Pulse width measurement0.01us resolution, maximum measurable 20s
Period measurement0.01us resolution, maximum measurable 20s

4.8. General Specifications

ParameterValue
Display type2.4 inch TFT color LCD
Storage and load (Quantity)100 groups
Storage and load (Position)00 to 99 (00 memory location parameter is loaded by default as power on)
Arbitrary wave (Quantity)1 to 60, totally 60 groups (15 groups by default as power on)
Interface modeUSB to serial interface
Extension interfaceWith TTL level mode serial interface for user secondary development
Communication speedStandard 115200bps
ProtocolUsing the command line, the protocol is made public
Power supplyDC 5V±0.5V
Manufacturing processSurface-mount technology, large scale integrated circuits, high reliability, long service life
Prompt toneUsers can turn on or off by setting program
Operating characteristicsAll key operations, knob continuous adjustment
Environmental conditionsTemperature: 0~40℃; Humidity: <80%
Dimensions (L x W x H)194mm x 178mm x 69mm

5. Initial Setup

5.1. Power Connection

  1. Connect the provided power adapter to the DC5V supply socket on the rear panel of the JDS6600.
  2. Plug the power adapter into a suitable power outlet.

5.2. Power On/Off

  1. Press the Power Button on the front panel to turn on the device.
  2. The device will display a welcome screen, followed by a language selection interface. Use the softkeys to select your preferred language (e.g., English). After initial setup, the device will directly enter the main interface on subsequent power-ons.
  3. To turn off the device, press and hold the Power Button until the display shuts down.

5.3. PC Software Installation

The included CD contains PC software for advanced control and arbitrary waveform generation. You can also download the latest software and communication protocols from the JUNCTEK website: www.junteks.com.

  1. Insert the CD into your computer's drive or download the software package.
  2. Follow the on-screen instructions to install the software and necessary drivers.
  3. Connect the JDS6600 to your PC using the provided USB data cable.

6. Operating Instructions

6.1. Setting Parameters and Outputting Waveforms (Main Interface)

  1. Simultaneous Output: Press the OK button to toggle the simultaneous output of both channels (CH1 and CH2) on or off.
  2. Channel Selection: Use the CH1 or CH2 buttons to select the currently active channel. Pressing the selected channel button again will toggle its output on/off. A long press on a channel button will set it as the main display (upper part of the screen).
  3. Waveform Selection: Press the WAVE softkey to activate waveform switching for the current channel. Use the Shuttle Knob or the Direction Keys (left/right) to quickly switch between arbitrary waveforms and preset waveforms.
  4. Frequency Setting: Press the FREQ softkey to highlight the "Frequency" parameter. Use the Direction Keys to move the cursor to the desired bit, then rotate the Shuttle Knob to change the value. Long press the FREQ softkey to change the frequency unit (MHz, KHz, Hz, mHz, uHz).
  5. Parameter Initialization: Press and hold the softkeys for Duty Cycle, Offset, and Phase to reset them to their default values.

6.2. MEAS Measurement Mode

The JDS6600 can measure various parameters of an input signal via the Ext. IN interface.

JDS6600 connected to oscilloscope showing measurement function
Measurement function in action, displaying frequency, period, and duty cycle.
  1. Enter Measurement Mode: Press the MEAS shortcut key to enter the measurement mode interface.
  2. Function Selection: In the measurement mode interface, press the FUNC softkey to switch between the measurement function (frequency, period, pulse width, duty cycle) and the counter function. You can also use the Shuttle Knob to switch.
  3. Coupling Mode: Press the COUP softkey to switch between AC and DC coupling modes.
  4. Gate Time Setting: Use the softkeys to set the gate time (0.01S-10S).
  5. Start/Stop Counting: After setting all parameters, press the OK softkey to start the counting function and the OFF softkey to stop.

6.3. MOD Modulation Mode

The MOD mode allows for sweep, pulse, and burst functions.

  1. Enter Modulation Mode: Press the MOD shortcut key to enter the modulation mode interface.
  2. Function Selection: Press the FUNC softkey to switch between Sweep Function (CH1/CH2), Pulse Function (CH1), and Burst Function (CH1).

6.3.1. Sweep Function

The sweep function allows linear or logarithmic frequency sweeps.

JDS6600 connected to oscilloscope showing frequency sweep
Frequency sweep function output on an oscilloscope.
  1. Parameter Selection: In the sweep function (CH1 channel), use the softkeys to select starting frequency, end frequency, sweep time (0.1s-999.9s), sweep direction (forward, reverse, round trip), and sweep mode (linear, logarithmic).
  2. Editing Parameters: When an item is highlighted, use the Direction Keys and Shuttle Knob to edit its parameters.
  3. Start/Stop Sweep: Press the ON softkey to start the sweep function and the OFF softkey to stop.

6.3.2. Pulse Function

The pulse function allows precise adjustment of pulse width and period.

JDS6600 connected to oscilloscope showing pulse function
Pulse function output on an oscilloscope.
  1. Parameter Selection: In the pulse function (CH1 channel), use the softkeys to select pulse width, period, offset, and amplitude.
  2. Editing Parameters: When an item is highlighted, use the Direction Keys and Shuttle Knob to edit its parameters. Press the OK softkey to switch pulse width and period units (ns/us).
  3. Start/Stop Pulse: Press the ON softkey to start the pulse function and the OFF softkey to stop.

6.3.3. Burst Function

The burst function allows outputting a specific number of pulse trains (1-1048575 periods).

JDS6600 connected to oscilloscope showing burst function
Burst function output on an oscilloscope.
  1. Parameter Selection: In the burst function (CH1 channel), use the softkeys to select the number of pulses and the burst mode (Manual burst, CH2 burst, external burst (AC), external burst (DC)).
  2. Editing Parameters: When an item is highlighted, use the Direction Keys and Shuttle Knob to edit its parameters.
  3. Start/Stop Burst: Press the ON softkey to start the burst function and the OFF softkey to stop.
  4. Important Note: The period time of the burst train must be less than the burst signal period time.

6.4. System Settings

The system settings allow customization of various device parameters.

Screenshot of JDS6600 system settings interface
System settings interface.
  1. Enter System Settings: Press the SYS shortcut key to enter the system setting interface.
  2. Parameter Selection: Use the softkeys to select parameters such as in/out position, sound settings, brightness adjustment, language settings, synchronization function settings, and arbitrary wave display quantity settings.
  3. Call Out & Save: This function allows you to save or recall current waveform parameters to a specified memory position (00-99). Rotate the Shuttle Knob to select the position, then use the corresponding softkey to recall, save, or clear.
  4. Sound Settings: Toggle the prompt tone on or off using the ON/OFF softkeys.
  5. Brightness Adjustment: Adjust the display brightness from 0 to 12 levels using the Shuttle Knob.
  6. Language Setting: Select English or Chinese display using the corresponding softkeys.
  7. Synchronization: When CH1 is set as the operation target, CH2 parameters will follow CH1. When the synchronization item is highlighted, use the Direction Keys or Shuttle Knob to select the item to be synchronized (frequency, waveform, amplitude, duty cycle, offset). Press ON to select and OFF to cancel.
  8. Arbitrary Waveform Number Setting: Adjust the number of arbitrary waveforms (1-60) displayed on the main interface using the Shuttle Knob.

7. PC Software Usage

The JDS6600 comes with PC software that allows for advanced control and the creation of custom arbitrary waveforms. This greatly expands the instrument's capabilities for complex signal generation.

Screenshot of JDS6600 PC software interface for arbitrary waveform generation
PC software interface for arbitrary waveform generation.
  1. Connect to PC: Ensure the JDS6600 is connected to your computer via the USB cable and the PC software is installed and running.
  2. Arbitrary Waveform Editing: Use the software's interface to draw or define arbitrary waveforms. The software provides a graphical interface for this purpose.
  3. Download to Instrument: Once your custom waveform is designed, use the software to download it to one of the 60 arbitrary wave storage groups on the JDS6600.
  4. Output Custom Waveform: Select the stored arbitrary waveform on the JDS6600 device to output it.
  5. Remote Control: The PC software also allows for remote control of most instrument functions, providing a more convenient way to configure and operate the signal generator.

8. User Tips

  • Grounding: Always ensure proper grounding of the instrument and connected devices for accurate measurements and to prevent electrical interference.
  • Arbitrary Waveforms: For complex or custom signal requirements, leverage the PC software to design and upload arbitrary waveforms. This offers greater flexibility than the built-in standard waveforms.
  • Sweep Modes: Experiment with both linear and logarithmic sweep functions to understand their applications in different testing scenarios, such as filter response analysis.
  • Pulse Width Adjustment: When working with pulse signals, utilize the precise digital pulse width adjustment feature for critical timing applications.
  • Dual Channel Independence: Remember that the two channels are completely independent, allowing for simultaneous output of different waveforms or synchronized outputs with adjustable phase differences.

9. Troubleshooting

9.1. General Issues

  • No Power: Check the power adapter connection and ensure the power outlet is functional. Verify the power button is pressed.
  • No Output Signal: Ensure the channel output is enabled (check CH1/CH2 buttons and OK button status). Verify BNC cable connections. Check amplitude and frequency settings.
  • Incorrect Waveform: Confirm the selected waveform type and parameters. If using arbitrary waveforms, ensure they were correctly uploaded from the PC software.
  • Display Issues: Adjust the brightness in the System Settings. If the display remains blank or distorted, power cycle the device.

9.2. Contacting Support

If the instrument is damaged, not working properly, or fails performance tests, please contact your dealer or JUNCTEK directly for assistance. Do not attempt to repair the device yourself.

10. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the exterior of the instrument. Do not use abrasive cleaners or solvents.
  • Storage: Store the JDS6600 in a cool, dry place, away from direct sunlight, moisture, and extreme temperatures (0~40℃, humidity <80%).
  • Handling: Handle the instrument with care to avoid physical damage.

11. Support & Contact Information

For any problems, technical support, or inquiries regarding your JDS6600 Signal Generator, please contact JUNCTEK:

You can also find software and communication protocol downloads on the official website.

Overview of the JDS6600 Signal Generator's features and interfaces.

For a more detailed guide, please refer to the official user manual PDF: User manual (PDF)

© 2024 JUNCTEK. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.