1. Introduction
Thank you for purchasing the RIDEN RD6012/RD6012W Digital Control DC Power Supply. This device is a constant voltage and constant current adjustable buck converter designed for various applications requiring precise power control. This manual provides detailed instructions for setup, operation, maintenance, and troubleshooting to ensure optimal performance and user safety.
Note:
- This instruction manual corresponds to specific firmware versions (RD6012 V1.37, RD6012P V1.49). Page layouts and operations may differ slightly with other firmware versions. We recommend downloading the latest firmware for the best experience.
- The RD6012 model supports USB communication, while the RD6012W model includes a WiFi communication board for wireless control via mobile apps.
Product Overview Video
Product overview and feature demonstration for the RIDEN RD6012/RD6012W DC Power Supply.
2. Package Contents
Upon opening the product box, you will find the following items:
- RD Power Supply (Main Unit)
- Instruction Card (with QR code to view digital instructions)
- External Temperature Sensor (10K B3950)
- Backup Fuse
- WiFi Communication Board (Only for RD6012W model)

Contents of the RD6012W package, including the main unit, temperature sensor, WiFi communication board, and documentation.
3. Specifications
General Parameters
- Input Voltage Range: 6-70V DC
- Output Voltage Range: 0-60.00V DC
- Output Current Range: 0-12.00A DC
- Output Power Range: 0-720W
- Display: 2.4-inch color HD display
- Working Temperature: -10°C to 40°C
- Product Dimensions: 167mm * 81mm * 65mm
- Weight (with package): Approximately 0.61 kg
Detailed Technical Parameters
| Parameter | Value |
|---|---|
| Output Voltage Setting Resolution | 0.01V |
| Output Voltage Accuracy | ±(0.3%+3 digits) |
| Output Current Resolution | 0.01A |
| Output Current Accuracy | ±(0.5%+5 digits) |
| Input Voltage Resolution | 0.01V |
| Input Voltage Accuracy | ±(1%+5 digits) |
| Battery Voltage Resolution | 0.01V |
| Battery Voltage Accuracy | ±(0.5%+3 digits) |
| Default Cutoff Current (charging) | 100mA |
| Output Ripple Typical (VPP) | 250mV@6A |
| External Sensor Temp. Detection Range | -10°C to 100°C / 0°F to 200°F |
| External Sensor Temp. Detection Accuracy | ±3°C / ±6°F |
| Constant Voltage Mode Response Time | 2ms (0.1A-5A load) |
| Constant Voltage Mode Load Regulation | ±(0.1%+2 digits) |
| Constant Current Mode Load Regulation | ±(0.1%+3 digits) |
| Capacity Measurement Range | 0-9999.99Ah |
| Energy Measurement Range | 0-9999.99Wh |
| Capacity and Energy Statistical Error | ±2% |
| Over Temperature Protection | System temperature >80°C |
| Cooling Fan Start Condition | Output current >8A or System temperature >45°C |
| Cooling Fan Shut Down Condition | Output current <7.9A and System temperature <45°C |

Detailed dimensions of the RD6012 power supply module and its packaging.
4. Setup
4.1 Panel Overview

Front panel of the RD6012/RD6012W, highlighting the 2.4-inch HD screen, keypad, and control interface.
Front Panel Components
- A: Power button
- B: SHIFT Second function button
- C: Quick storage button
- D: Current/Over current protection setting
- E: Voltage/Over voltage protection setting
- F: Micro USB port
- G: Power supply output negative terminal / Battery charging negative terminal
- H: Battery charging positive terminal (Dedicated terminal for battery charging)
- I: Power supply output positive terminal (connect 4mm banana plug)
- J: Output ON/OFF switch
- K: Enter/Confirm button
- L: Encoder potentiometer (rotate) / Cancel button (Press)
- M: Direction button
- N: Keypad
- O: Screen
Back Panel Components (RD6012/RD6012-W)

Internal view of the RD6012 module, showing the fan, capacitors, and connection points.
- P: Input fuse (Type: 1808)
- Q: Output fuse
- R: Power source input interface (HT508K/K14)
- S: External temperature sensor interface (XH2.54-2P)
- T: CR1220 battery socket
- U: Communication module interface (WiFi or RS485 board)
- V: Fan interface (cannot add or replace other fan)
Important Fuse Information:
- RD6012/RD6012P uses a 20A fuse.
- If the fuse is damaged, solder a new fuse. When using a fuse holder as a temporary replacement, ensure the output current is less than 10A, as fuse holders typically have a maximum capacity of 10A.
4.2 Power Source Recommendations
The power source input interface (R) must be connected to a 7-70V constant DC power source. If the input voltage exceeds 72V, the output will automatically turn off, and an alarm will be displayed. Exceeding the input voltage limit can permanently damage the product.

Recommended and banned power supply units (PSUs) for use with the RD6012.
Recommended PSUs:
- Custom PSUs or reputable brand PSUs.
- For AC input, a switching power supply must be used and reliably grounded to prevent leakage.
Not Recommended/Banned PSUs:
- AC-DC converters or transformers without proper rectification and filtering. DC output voltage without load should be lower than 65V.
- Electric bike chargers, second-hand power supplies, or modified power supplies. These can have unstable outputs and high voltage peaks that may damage the device.
4.3 Assembly Instructions
Only individuals with a foundational understanding of electronic and electrical engineering should connect the cables. Ensure reliable grounding.

Correct installation method for the RD6012 module into a compatible case.
Important:
- Do not install or remove the Wi-Fi module when the device is powered on, as this may cause damage.
- The RD6012 does not include a case, power source, or cables. These accessories must be purchased separately for a complete setup.
5. Operation
5.1 Basic Operation
After power-on, the device will first show a boot image, then enter the main display page.
Main Page Display Styles

The RD6012 supports both Traditional (default) and Curve display styles. The curve style shows real-time output voltage, current, and power graphs.
You can switch between Traditional, Detail, and Curve display styles. In curve style mode, rotate the encoder potentiometer to scale the vertical coordinate of the curve. Press the ENTER button to pause/start curve recording. To set a default boot display style, refer to the System Settings section.
Setting Output Voltage and Current
- Press the I-SET button to set the output current value. Use the encoder potentiometer to adjust the value directly.
- Press the V-SET button to set the output voltage value. Operation is similar to current setting.
- Use the keypad to type in values and press ENTER to confirm.
- If a value exceeds the limit, an error message will be displayed.
Over Voltage Protection (OVP) and Over Current Protection (OCP)

Setting and indication of Over Voltage Protection (OVP) and Over Current Protection (OCP).
- Press SHIFT + I-SET to set OCP.
- Press SHIFT + V-SET to set OVP.
- When the output voltage/current exceeds the set protection value, the output will automatically shut down to prevent damage.
Data Storage and Recall
- Press MEM + keypad button (1-9) to store current settings.
- Press SHIFT + keypad button (1-9) to quickly recall saved data.
Keypad Lock and Unlock
- Press SHIFT + LOCK to lock or unlock the keypad.
- The keypad will automatically lock when communication starts. It will unlock after 3 seconds if communication is disconnected.
System Settings
Access the system settings menu by pressing SHIFT + 0. Use the encoder potentiometer to navigate and adjust settings.
- Language: Set to English, Simplified Chinese, French, German, or Russian.
- Take OK: When ON, prompts for confirmation when recalling data groups.
- Take Out: When ON, automatically outputs directly when recalling data groups.
- Boot Power: When ON, output automatically turns on after booting.
- Boot Logo: When ON, displays the boot logo first.
- Buzzer: When ON, a beep sounds when buttons are pressed.
- Backlight: Adjustable from level 0-5.
- Update Rate: Sets the refresh rate of real output voltage and current (Low/Mid/High).
- Max Power: Sets the maximum output power (0-740W).
- Battery Charger Cutoff Current/Temp: Sets the cut-off conditions for battery charging.
- Communication Interface: Set to USB, WiFi, or RS485.
- Date and Time: Set the device's date and time.
- Layout: Adjust Digits Style and Home Style.
- Custom Colors: Customize display colors for various parameters.
5.2 Battery Charging Function
The RD6012/RD6012W can be used for battery charging. Connect the green terminal (H) to the battery's positive electrode and the black terminal (G) to the negative electrode. The battery charging indicator (AG) will turn red when connected, then green when charging starts.
Warning:
- The charging function is a temporary replacement; it is strongly recommended to use the original charger for long-term battery charging.
- Non-professionals should not use the battery charging function due to the risk of fire and explosion if used incorrectly.
- Ensure you know your battery's parameters well before charging.
- Upgrade to the latest firmware for a better battery charging experience.
Battery Voltage Comparison Tables
| Battery Type | Nominal Voltage (V) | Final Charge Voltage (V) | Final Discharge Voltage (V) | Application | Characteristics |
|---|---|---|---|---|---|
| LiCoMnNiO2 | 3.7 | 4.2 | 3 | Digital Device | High capacity |
| LiFePO4 | 3.2 | 3.65 | 2.5 | Electric bike/electric tool | Large discharge current, inexpensive |
| Lead Storage Battery | 12 | 14.4 | 10.5 | Car/electric bike | Inexpensive, Lead pollution |
| Dry Battery | 1.5 | Cannot charge | 0.9 | Clock/Remote control | Inexpensive, widely used, not rechargeable |
| NICD Battery | 1.25 | 1.5 | 1.1 | Toy | Inexpensive, Memory effect |
| Ni-MH Battery | 1.2 | 1.4 | 0.9 | Toy/Shaver | No memory effect |
| Nominal Voltage | Battery Type | Number of batteries connected in series | Final Discharge Voltage (V) | Final Charge Voltage (V) |
|---|---|---|---|---|
| 48V | LiCoMnNiO2 | 14 | 42 | 58.8 |
| LiCoMnNiO2 | 13 | 39 | 54.6 | |
| LiFePO4 | 16 | 40 | 58.4 | |
| Lead Storage Battery | 4 | 42 | 57.6 | |
| 36V | LiCoMnNiO2 | 10 | 30 | 42 |
| LiFePO4 | 12 | 30 | 43.8 | |
| Lead Storage Battery | 3 | 31.5 | 43.2 | |
| 24V | LiCoMnNiO2 | 7 | 21 | 29.4 |
| LiFePO4 | 8 | 20 | 29.2 | |
| Lead Storage Battery | 2 | 21 | 28.8 |
Note: If the final discharge voltage of the battery is higher than 60V, you cannot use RD6024 to charge, it will damage the device.
5.3 PC Software Control
The PC software allows you to monitor and set the digital power supply on your computer. It supports Windows 7 to Windows 10 systems.

PC Software interface for controlling the RD6012/RD6012W via USB.
Software Download & Installation
PC software download link: PC Software Download
- Requirements: Windows 7-10 system with Internet connection.
- Driver Installation: The first time you use the software, install the CH341SER driver. Verify installation by checking for "USB-SERIAL CH340(COMXX)" in Device Manager.
- Software Execution: Unzip the files and run `RidenPowerSupply.exe`. Ensure .Net Framework 4.7.2 is installed.
Software Connection (USB)
- Set the RD6012P communication interface to USB.
- Connect the RD6012P to your PC using a Micro USB cable.
- In the software, choose the correct communication port, baud rate (default 001), and slave address. Click "CONNECT".
Software Connection (WiFi - RD6012W only)
Note: WiFi connection is a test function and may have compatibility issues with some computers. If you cannot connect via WiFi, please use USB. We do not guarantee or provide technical support for this function.
- Set the RD6012W communication interface to WiFi and restart the device.
- In the PC software, click "WiFi Network" to open the configuration interface.
- Click "Initialize" and wait 5-10 seconds.
- After the RD6012W displays its local IP address, click "Next", enter the WiFi name and password, then click "Network distribution".
- Wait about 20 seconds for the connection to succeed, then click "Connect".
Basic Functions (PC Software)
- Voltage/Current Preset: Set output values using the interface or by typing.
- Data Group Quick Call Out: Store and recall settings.
- Calibration Fine Tuning: Adjust calibration parameters (see Maintenance section).
- Brightness Setting: Adjust screen brightness.
- Voltage and Current Curve Exporting: View real-time curves and export data to picture or Excel.
Advanced Functions (PC Software)
- Programming Output: Set output voltage and current by chart with up to 200 steps, each between 1 and 9999 seconds.
- RS485 Multiple Devices Communication: Connect multiple RD6024 units (up to 32) using a USB to RS485 module. Each device needs a different address.
5.4 Mobile App Control (RD6012W only)
The RD6012W supports wireless control via mobile apps for Android and iOS.
Android App Installation
Android App download link: Android App Download
- Supported OS: Android 5.0 to Android 12.0.
- Location Service: The app requires location service to be enabled.
- WiFi Module: Do not install or remove the Wi-Fi module when the device is powered on.
- Permissions: Allow necessary permissions (background running, Bluetooth, storage, etc.) for proper app function.
iOS App Installation
iOS App: Search for "RDPower" (or "RUIDENG" if "RDPower" is unavailable) in the Apple App Store.
- Supported OS: iOS 10.0-16.1, iPhone 6 and above models.
- Location Service: Enable location services in Settings > Privacy for WiFi functionality.
App Network Distribution
- Insert the WiFi board correctly and power on the RD6012W. The blue LED should blink once.
- Set the communication interface to WiFi on the device.
- Place the RD6012W and your mobile phone close to a 2.4G router. Ensure the router has AP isolation and WMM functions disabled.
- In the app, select "Add Device" and choose "RD power series". Enter your WiFi password and confirm you are using a 2.4G network.
- If using a Huawei phone, turn off the random MAC address function.
- If the IP address of the phone changes, you may need to reset the network by pressing the ENTER button and then the 4 button. Consider setting a fixed IP for your phone in the router settings.
6. Maintenance
6.1 Firmware Update
Firmware updates can add new functions and improve performance. It takes approximately 80 seconds to update the firmware.

Firmware update process using the PC software.
Firmware update video: Firmware Update Video
- Press and hold ENTER and power on the device to enter boot mode.
- Connect the device to the computer. The PC software will show "boot mode".
- Click "Firmware Update" in the PC software and follow the prompts to upgrade.
- If the device cannot start normally, update it under boot mode. Firmware updates are not supported via WiFi connection.
6.2 Boot Logo Update
You can customize the boot logo of the device.
Boot logo setting video: Boot Logo Update Video
- In the PC software, click "Start Logo Update".
- Select a picture from your computer. The device will reboot automatically after the update.
6.3 Version Update Detection
In the PC software, click "Software Update" to automatically detect if a new version is available. An update prompt will appear if a new version is found.
6.4 Calibration
Warning: Calibration should only be performed by professional electronic personnel with a high-precision multimeter. Incorrect operation can exceed hardware limits and cause damage, voiding the warranty. This section does not provide technical support; please check related information if you do not understand.
Calibration operation video: Calibration Video
- Click "Calibration" in the PC software and enter the password "168168".
- Adjust the output voltage zero point and proportional value (e.g., at 1V and 30V) to match the multimeter display.
- Similarly, adjust the output current zero point and proportional value (e.g., at 0.1A and 3A).
7. Troubleshooting
Product Related Questions
- Q: What are the differences between RD6012 and RD6012-W?
A: The RD6012W includes a WiFi board for app connectivity, while the RD6012 does not. Both support PC software via USB. - Q: Why does the product I received look slightly different from the pictures?
A: We continuously update product hardware and software for improvement. Internal material details may vary, but this does not affect functionality. - Q: Why is there a fuse in the box? Should I install it?
A: It's a backup fuse. If the original fuse burns out due to incorrect operation, you can temporarily use the backup fuse in the socket. Note that the backup fuse supports only 10A. For full output, it's best to solder a new fuse in the original position. - Q: Can I use it to power an inductive load?
A: If connecting an inductive load (e.g., a motor), the maximum working current should not exceed 1/3 of the device's full range. - Q: The case I received is slightly deformed or has scratches. Is this normal?
A: Minor deformation or scratches on the case may occur during shipping. These can often be adjusted by hand and do not affect product performance. If you are concerned about cosmetic imperfections, please consider this before purchase. - Q: Does the 800W65V PSU have high-frequency noise?
A: Some 800W65V PSUs may produce high-frequency noise when powered on without a load. Adding a load resistor can improve this. If noise is a significant concern, please consider this before purchasing the PSU.

Adding a load resistor to the 800W65V PSU to mitigate high-frequency noise.
Software & App Related Questions
- Q: The app crashes on my phone, or I experience incompatibilities. What should I do?
A: Due to potential incompatibilities between the app/PC software and various operating systems (e.g., Harmony OS), we recommend downloading and testing the software/app before purchasing the product. If you find that the product functions correctly but the software/app does not, refunds based solely on software/app issues may be refused. - Q: Why can't I connect the RD6012W to my phone app via WiFi?
A: Ensure the WiFi board is properly inserted. Verify your WiFi network is 2.4GHz. Disable client isolation/AP isolation and WMM functions on your router. Ensure location and storage services are enabled for the app. If issues persist, contact support. - Q: Why can't I connect the RD6012W to my PC via WiFi, even though it connects to my phone?
A: WiFi connection to PC is a test function and may have poor compatibility with some computers. If PC WiFi connection fails, please use USB communication.
8. User Tips
- Always check PSU output: Before connecting any load, use a multimeter to verify the actual output voltage of your power supply unit (PSU) to ensure it's stable and within the rated voltage. This prevents potential damage to your RD6012/RD6012W.
- Ensure proper grounding: When using a switching power supply for AC input, ensure it is reliably grounded to prevent electrical leakage and ensure safety.
- Router settings for WiFi: For seamless app connectivity with the RD6012W, ensure your 2.4GHz WiFi router has AP isolation and WMM functions disabled.
- Inductive loads: If powering inductive loads like motors, limit the working current to no more than one-third of the device's maximum current range to prevent overload.
- Firmware updates: Regularly check for and install the latest firmware updates to benefit from new features and performance improvements.
9. Support & Contact
For the most detailed and up-to-date information, including full user manuals and software downloads, please refer to the official documentation available online. The instruction card included in your package contains a QR code for direct access.
If you require further assistance or have questions not covered in this manual, please contact RIDEN Official Store support:

Contact details for RIDEN Official Store support.
- Email: 1749808860@qq.com
- WhatsApp: +8615868147353
- QQ Group: 550112838
- WeChat: 15868147353