1. Introduction
The HoldPeak HP-580S-APP is a professional 1000A AC/DC clamp meter designed for electricians, HVAC technicians, and industrial maintenance professionals. It features True RMS technology, a 6000-count display, and Bluetooth connectivity for data logging and analysis via the "AiLink" mobile app. This versatile tool combines multiple functions including current, voltage, resistance, capacitance, frequency, temperature, continuity, and diode testing, along with Non-Contact Voltage (NCV) detection for enhanced safety.
Figure 1: HoldPeak HP-580S Clamp Meter and accessories.
2. Package Contents
Verify that all items listed below are present and in good condition:
- HoldPeak HP-580S-APP Clamp Meter
- Carrying Case
- Test Leads (Red and Black)
- Temperature Probe
- Screwdriver
- Operation Manual
Figure 2: Unboxing and package contents.
Video 1: Unboxing and accessory connection demonstration.
3. Setup
3.1 Battery Installation
The device requires 2 x 1.5V AAA batteries (not included). Use the provided screwdriver to open the battery compartment on the back of the meter. Insert the batteries, ensuring correct polarity, then close the compartment securely.
3.2 Connecting Test Leads and Temperature Probe
For voltage, resistance, continuity, diode, and capacitance measurements, insert the black test lead into the "COM" jack and the red test lead into the "VΩ" jack. For temperature measurements, connect the temperature probe to the designated ports.
3.3 Mobile App Installation and Bluetooth Connection
The HP-580S-APP can connect to a mobile app for data logging and remote control. Scan the QR code provided in the manual or on the product packaging to download the "AiLink" app from Google Play or the App Store. Once installed, enable Bluetooth on your smartphone and within the app to connect to the clamp meter. The app allows for remote monitoring, data recording, and graphing of measurements.
Figure 3: App download and interface overview.
Figure 4: Bluetooth connection process with the mobile app.
4. Operating Instructions
The HP-580S-APP features a rotary switch for function selection and several buttons for additional features.
Figure 5: Rotary switch and button functions.
4.1 General Operation
- Rotary Switch: Turn the switch to select the desired measurement function (e.g., V~ for AC Voltage, V- for DC Voltage, Ω for Resistance, etc.).
- SELECT Button: Press to switch between different measurement types within a single rotary switch position (e.g., AC/DC voltage, Resistance/Diode/Continuity, °C/°F).
- HOLD Button: Press to freeze the current reading on the display. Long press for more than 2 seconds to turn on/off the backlight.
- MAX/MIN Button: Press to display the maximum or minimum measured value.
- REL Button: For relative value measurement.
- Hz% Button: For frequency and duty cycle measurement.
4.2 Specific Measurement Modes
4.2.1 DC Voltage Measurement
- Turn the rotary switch to the V- position.
- Insert the black test lead into the "COM" jack and the red test lead into the "VΩ" jack.
- Connect the test leads across the DC voltage source to be measured.
- The display will show the DC voltage. If the input exceeds 1000V DC, the buzzer will sound.
4.2.2 AC Voltage Measurement
- Turn the rotary switch to the V~ position.
- Press and hold the "SELECT" key to switch to the AC voltage measurement state.
- Insert the black test lead into the "COM" jack and the red test lead into the "VΩ" jack.
- Connect the test leads across the AC voltage source to be measured.
- The display will show the AC voltage. If the input exceeds 750V AC, the buzzer will sound.
Figure 6: AC & DC Voltage measurement.
4.2.3 Frequency Measurement
- Turn the function switch to the "Hz" position.
- Connect the test leads to the circuit to measure frequency.
4.2.4 DC Current Measurement
- Turn the rotary switch to the 600A~1000A position.
- Open the clamp jaw and enclose a single conductor carrying DC current.
- The display will show the DC current.
4.2.5 AC Current Measurement
- Turn the rotary switch to the 600A~1000A position.
- Press the "SELECT" key to switch to AC current measurement.
- Open the clamp jaw and enclose a single conductor carrying AC current.
- The display will show the AC current. If the test value is higher than 600A, please adjust the dial to the corresponding gear (1000A).
Figure 7: AC Current Clamp Meter measurement.
4.2.6 Temperature Test
- Turn the function selector switch to the "°C/°F" position.
- Connect the temperature probe to the meter.
- Place the probe in contact with the object or environment whose temperature is to be measured.
- Press and hold the "SELECT" key to switch between °C and °F temperature units.
Figure 8: Temperature test using the probe.
4.2.7 Resistance Test
- Turn the rotary switch to the Ω position.
- Connect the test leads across the component to measure its resistance.
Figure 9: Resistance test.
4.2.8 Continuity Test
- Turn the rotary switch to the Ω position.
- Press the "SELECT" key to switch to continuity test mode.
- Connect the test leads across the circuit or component. An audible beep indicates continuity.
Figure 10: Continuity test.
4.2.9 Diode Test
- Turn the rotary switch to the Ω position.
- Press the "SELECT" key multiple times to cycle to diode test mode (indicated by a diode symbol).
- Connect the red test lead to the anode and the black test lead to the cathode of the diode. The forward voltage drop will be displayed. Reverse the leads to check for open circuit.
Figure 11: Diode test.
4.2.10 Capacitance Test
- Turn the rotary switch to the Ω position.
- Press the "SELECT" key multiple times to cycle to capacitance test mode (indicated by a capacitance symbol).
- Connect the test leads across the capacitor. The capacitance value will be displayed. Note that measuring large-capacity capacitors may take time to stabilize.
Figure 12: Capacitance test.
4.2.11 NCV (Non-Contact Voltage) Detection
- Turn the rotary switch to the NCV position.
- Place the NCV sensor near the conductor.
- If AC voltage is detected, the meter will beep and the NCV indicator light will illuminate.
5. Maintenance
To ensure the longevity and accuracy of your HoldPeak HP-580S Clamp Meter, follow these maintenance guidelines:
- Cleaning: Wipe the meter with a dry, soft cloth. Do not use abrasives or solvents.
- Storage: Store the meter in its carrying case in a cool, dry place away from direct sunlight and extreme temperatures.
- Battery Replacement: Replace batteries promptly when the low battery indicator appears on the display to ensure accurate readings. Remove batteries if the meter will not be used for an extended period.
- Calibration: For professional use, periodic calibration by a qualified technician is recommended to maintain accuracy.
6. Troubleshooting
If you encounter issues with your clamp meter, refer to the following common problems and solutions:
- No Display/Power On: Check battery installation and ensure batteries are not depleted. Replace if necessary.
- Inaccurate Readings: Ensure test leads are properly connected and not damaged. Verify the correct function is selected on the rotary switch. Check for external interference.
- No Bluetooth Connection: Ensure Bluetooth is enabled on both the meter and your smartphone. Restart the app and the meter. Make sure the meter is within range of your phone.
- Overload Protection: If the buzzer sounds during voltage measurement, the input may exceed the maximum effective value. Disconnect immediately to prevent damage.
If problems persist, contact customer support for assistance.
7. Specifications
| Parameter | Specification |
|---|---|
| Model | HP-580S-APP |
| Display | 6000 counts |
| DC Current Range | 0-1000A (±2.5%-3.0%) |
| AC Current Range | 0-1000A (±2.5%-3.0%) |
| DC Voltage Range | 600mV~1000V (±0.5%-1.5%) |
| AC Voltage Range | 6V~750V (±0.5%-1.5%) |
| Resistance Range | 600Ω~ 60MΩ (±1.0%-1.5%) |
| Capacitance Range | 6nF~60mF |
| Temperature Range | -20°C ~ 1000°C / -4°F ~ 1832°F |
| Frequency Range | 9.999Hz/ 99.99Hz/999.9Hz/ 9.999kHz/99.99kHz/999.9kHz/9.999mHz |
| Duty Cycle | 0.1%~99.9% |
| NCV Detection | 90V~1000V AC rms |
| Auto Range | YES |
| Test Diode / Continuity Buzzer | YES |
| Back Light / Data Hold | YES |
| Auto Power Off | YES |
| Relative Value | YES |
| True RMS | YES |
| MAX/MIN | YES |
| Jaw Caliber | 26mm |
| Battery Type | 1.5V(AAA)*2 |
| Dimensions | 265x100x42mm |
| Weight | 400g |
Figure 13: Physical dimensions of the clamp meter.
8. User Tips
- Always ensure the correct function is selected before making any measurements to avoid damage to the meter or the circuit.
- When measuring current with the clamp, ensure only one conductor is enclosed within the jaw for accurate readings.
- Utilize the Bluetooth app for long-term data logging and trend analysis, which can be very helpful for diagnosing intermittent issues.
- The backlight feature is useful in dimly lit environments; remember to long-press the HOLD button to activate it.
- For large capacitance measurements, be patient as the meter may take a few seconds to stabilize and provide an accurate reading.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the contact information provided by your retailer or the manufacturer's official website. Keep your purchase receipt as proof of purchase.