1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of your Wofea Wired PIR Sensor Infrared Motion Detector (Model: ZC-S002W). This device is designed to detect motion using passive infrared technology and integrate into a home alarm system, providing reliable security monitoring.
2. Product Features
- Fireproof ABS housing for enhanced safety.
- Automatic temperature compensation for stable performance across varying temperatures.
- SMT (Surface-Mount Technology) adopted, providing anti-RFI (Radio Frequency Interference) & anti-EMI (Electromagnetic Interference) capabilities.
- Pulse count optional for adjusting detection sensitivity.
- Alarm output with selectable N.C. (Normally Closed) / N.O. (Normally Open) options.
3. Specifications
| Parameter | Value |
|---|---|
| Operating Voltage | DC 12V (DC9-DC12V) |
| Consumption Current | Less than 18mA (DC12V) |
| Operating Temperature | -10 to +50°C |
| Installation Mode | Wall mounted |
| Installation Height | Approximately 2.2m |
| Detecting Distance | 12m |
| Detecting Angle | Horizontal: 110 degrees; Vertical: 60 degrees |
| Alarm Output | N.O. / N.C. optional |
| Anti-Dismantle Switch | N.C. |
| Dimension | 89 x 52.5 x 38.5mm |
4. Package Contents
- 1x Wofea Wired PIR Sensor
- 1x Mounting Bracket
Note: Power supply (DC12V) is not included.
5. Setup and Installation
The PIR sensor is designed for wall-mounted installation. For optimal performance, install the sensor at an approximate height of 2.2 meters.
5.1 Physical Installation
- Carefully open the sensor casing to access the internal circuit board.
- Attach the mounting bracket to the desired wall location using appropriate screws (not included).
- Secure the sensor to the mounting bracket. The bracket allows for adjustment of the detection angle.



5.2 Wiring Diagram
Refer to the internal circuit board diagram for correct wiring. The sensor requires a DC 9-12V power supply.

Wiring Terminals:
- +12V: Positive power input (DC9-12V).
- GNG: Ground connection.
- TAMPER: Tamper switch output. Connect these two terminals to your alarm system's tamper zone. If the sensor cover is opened, it will activate the alarm.
- ALARM (NO/NC): Alarm output. These terminals provide either Normally Open (NO) or Normally Closed (NC) contacts, configurable via jumpers. Connect these to your alarm system's zone input.
Internal Components:
- Pulse Jumper: Used to adjust the pulse count for detection.
- NO, NC Output Adjust Jumper: Used to set the alarm signal type to Normal Open (NO) or Normal Closed (NC).
- Dual Element IR Sensor: The core infrared detection component.
- LED Jumper: Used to set the LED indicator light to be on or off during operation.
- Anti-dismantle Switch: A physical switch that triggers an alarm if the sensor casing is opened.
- Wire Exit: Point for routing the wiring out of the sensor casing.
5.3 Connecting to an Alarm System
The sensor can be connected to a control unit or directly to a compatible 12V siren, depending on your alarm system's requirements. Ensure the alarm output (NO/NC) is correctly configured to match your alarm panel's zone input type.
6. Operation
Once properly wired and powered, the PIR sensor will begin its detection cycle. The LED indicator (if enabled) will typically flash during detection or when the sensor is in an alarm state.
6.1 Adjusting Alarm Output Type (NO/NC)
Use the 'NO, NC Output Adjust Jumper' on the circuit board to select the desired alarm output type (Normally Open or Normally Closed) to match your alarm panel's requirements.
6.2 LED Indicator Control
The 'LED Jumper' allows you to enable or disable the LED indicator light. Disabling the LED can make the sensor less conspicuous.
6.3 Sensitivity Adjustment
The sensor's sensitivity can be adjusted using the jumpers located on the circuit board. This allows you to set the detection level to high, medium, or low, depending on the environment and desired performance.
7. Maintenance
- Keep the sensor lens clean and free from dust or obstructions. Use a soft, dry cloth for cleaning.
- Periodically check all wiring connections to ensure they are secure.
- Avoid placing the sensor near heat sources, direct sunlight, or areas with strong air currents, as these can cause false alarms.
8. Troubleshooting
- No detection or false alarms: Check the sensitivity settings via the internal jumpers. Ensure the sensor is not exposed to direct heat, sunlight, or strong drafts. Verify the installation height is approximately 2.2m.
- Alarm not triggering: Confirm the alarm output (NO/NC) jumper setting matches your alarm panel's requirements. Check all wiring connections for continuity and proper polarity.
- Tamper alarm constantly active: Ensure the sensor cover is securely closed and the anti-dismantle switch is properly engaged.
- Compatibility with alarm systems: This wired PIR sensor provides standard NO/NC alarm outputs and a tamper switch, making it compatible with most wired alarm control panels that accept these input types. For direct siren connection, ensure the siren is 12V and compatible with the sensor's NO/NC output.
9. User Tips
- Thoroughly test the sensor upon receipt and before final installation to ensure full functionality.
- Consider the environment when adjusting sensitivity; a lower sensitivity might be suitable for areas with pets to prevent false alarms.
10. Warranty and Support
For any issues or questions regarding your Wofea Wired PIR Sensor, please contact your retailer or the manufacturer's customer support. Keep your purchase receipt for warranty claims.