Model: TM-6002

Introduction

The Tenmars TM-6002 is a versatile battery impedance and voltage tester designed for automotive, UPS maintenance, and telecommunication applications. It provides quick response times and simultaneously displays battery impedance and voltage measurements. The built-in comparator function allows for rating battery conditions as Pass, Warning, or Fail, simplifying battery health assessment.

Product Overview Video

This video provides a visual overview of the Tenmars TM-6002 Battery Impedance Tester and its included accessories.

Package Contents

Ensure all items are present and in good condition upon unpacking:

  • Tenmars TM-6002 Battery Impedance Tester Unit
  • Test Leads (Red, Black, Yellow, Blue)
  • Alligator Clips (Red, Black)
  • USB Cable
  • AC/DC Power Adapter
  • User Manual
  • Carrying Pouch
  • Kickstand
Tenmars TM-6002 Battery Impedance Tester and all accessories laid out

Image showing the Tenmars TM-6002 tester along with its test leads, alligator clips, USB cable, power adapter, user manual, and carrying pouch.

Setup

1. Battery Installation

  1. Ensure the device is powered off.
  2. Locate the battery compartment on the back of the tester.
  3. Open the battery compartment cover.
  4. Insert 6 x 1.5V AA alkaline batteries, observing correct polarity.
  5. Close the battery compartment cover securely.
Back view of Tenmars TM-6002 showing battery compartment warning

Back view of the TM-6002 tester, highlighting the battery compartment and a warning label to disconnect all test leads before opening the battery cover.

2. Connecting Test Leads

Connect the test leads to the appropriate terminals on the top of the device. The terminals are color-coded for easy identification:

  • SOURCE/SENSE (Red/Black): For impedance and voltage measurements.
  • DCA (Red/Black): For clamp transducer connection (if applicable).
  • TEMP (Yellow/Blue): For temperature sensor connection.
Top view of Tenmars TM-6002 showing input terminals

Top view of the TM-6002 tester, showing the clearly labeled and color-coded input terminals for SOURCE/SENSE, DCA, and TEMP, along with a USB port.

3. Powering On

Press the POWER button (green circle with power symbol) to turn on the device. The LCD display will illuminate.

Front view of Tenmars TM-6002 Battery Impedance Tester

Front view of the Tenmars TM-6002 Battery Impedance Tester, showing the LCD screen and control buttons.

Operating Instructions

1. Impedance Measurement

  1. Connect the red and black test leads to the SOURCE/SENSE terminals and then to the battery terminals (red to positive, black to negative).
  2. Press the Ω button to select impedance measurement mode.
  3. The device will display the battery impedance.

2. Voltage Measurement

  1. Connect the red and black test leads to the SOURCE/SENSE terminals and then to the battery terminals (red to positive, black to negative).
  2. Press the V button to select voltage measurement mode.
  3. The device will display the battery voltage.

3. Using the Comparator Function (PASS/WARNING/FAIL)

The TM-6002 features a comparator function to quickly assess battery health based on predefined thresholds.

  1. Press the COMP button to enter comparator setup mode.
  2. Use the arrow keys to set the high and low thresholds for impedance and voltage.
  3. Press COMP again to save settings and activate the comparator.
  4. During measurement, the device will indicate PASS, WARNING, or FAIL based on the battery's impedance and voltage relative to the set thresholds.

4. Data Memory and Datalogger

  • Manual Data Memory (MEMO): Press the MEMO button to manually save up to 999 data sets. Use the arrow keys to navigate through stored data.
  • USB Datalogger: The device supports USB data logging with a capacity of 9999 records. Connect the tester to a computer via the USB port and use the provided software for data transfer and analysis.

5. Other Functions

  • 0 ADJ (Zero Adjustment): Used to zero out the test leads' resistance before measurement for improved accuracy.
  • AVG (Average): Calculates the average of multiple measurements.
  • READ: Recalls stored data.
  • CLEAR: Clears data or settings.
  • HOLD: Freezes the current reading on the display.

Maintenance

1. Cleaning

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no moisture enters the device.

2. Battery Replacement

When the low battery indicator appears on the display, replace all six 1.5V AA alkaline batteries promptly to ensure accurate measurements. Always disconnect all test leads before opening the battery compartment.

3. Storage

If the device is not to be used for an extended period, remove the batteries to prevent leakage and damage. Store the tester in its carrying pouch in a cool, dry place away from direct sunlight and extreme temperatures.

Troubleshooting

  • No Display/Device Not Powering On: Check battery installation and ensure batteries are fresh. If using an external power adapter, verify it is correctly connected and functional.
  • Inaccurate Readings: Perform a 0 ADJ (zero adjustment) before measurement. Ensure test leads are securely connected and not damaged. Verify the correct measurement mode is selected.
  • Comparator Not Working: Recheck the high and low threshold settings in the comparator setup.
  • Data Transfer Issues: Ensure the USB cable is properly connected to both the tester and the computer. Verify that the data logging software is correctly installed and running.

Specifications

General

  • Battery Capacity: 0 to 500 A/h
  • Max. Voltage Measurement: 40VDC (battery checker)
  • Manual Data Memory: 999 data sets
  • USB Datalogger Capacity: 9999 records
  • Comparator: 0~99 records (high/low) for battery internal impedance and voltage
  • Power Supply: 6 x 1.5V AA alkaline batteries

Impedance Measurement

Measuring Frequency: 1KHz ±30Hz

Parameter40mΩ Range400mΩ Range4Ω Range40Ω Range
Resolution10µΩ100µΩ1mΩ10mΩ
Current100mA15mA1.5mA150µA
Accuracy± (0.8% reading + 10dgt)
Table showing impedance measurement specifications

Detailed specifications for impedance measurement ranges, resolution, current, and accuracy.

Voltage Measurement

Parameter4.000V Range40.00V Range
Resolution1mV10mV
Accuracy± (0.1% reading + 6dgt)
Table showing voltage measurement specifications

Detailed specifications for voltage measurement ranges, resolution, and accuracy.

Temperature Measurement

ParameterSpecification
Range-20°C ~ 60°C (-4°F ~ 140°F)
Resolution0.1°C / 0.1°F
Accuracy± 1°C ± 1.8°F
Table showing temperature measurement specifications

Detailed specifications for temperature measurement range, resolution, and accuracy.

User Tips

  • For consistent readings, ensure good contact between the test leads and battery terminals. Clean any corrosion from the terminals before testing.
  • When using the comparator function, calibrate the thresholds based on the manufacturer's specifications for the batteries you are testing to get the most accurate Pass/Warning/Fail indications.
  • Regularly back up your logged data to a computer to prevent loss, especially if performing extensive testing.
  • Keep the device and accessories in the provided carrying pouch to protect them from dust and physical damage when not in use.

Warranty & Support

For warranty information, technical support, or service inquiries, please refer to the contact details provided in the original product packaging or contact the seller directly. Keep your purchase receipt as proof of purchase.

Ask a question about this manual