Introduction
The VamsLuna Rechargeable Air Compression Leg Massager is a professional presotherapy device designed to enhance circulation, reduce pain and soreness, and accelerate recovery. Utilizing patented technology, this massager provides a restorative experience for your legs, helping you feel refreshed and revitalized.
Important Note: This device is designed to work with only two parts (leg attachments) at the same time.
Safety Information
Please read all instructions carefully before using the VamsLuna Leg Massager. Keep this manual for future reference.
- Consult your physician before using this device if you have any medical conditions, including but not limited to: heart disease, high blood pressure, diabetes, phlebitis, thrombosis, or if you are pregnant.
- Do not use the device on swollen, inflamed, or injured areas of the skin.
- Keep the device away from water and high humidity.
- Do not attempt to disassemble or repair the device yourself. Contact customer support for assistance.
- Keep out of reach of children and pets.
- Use only the provided power adapter for charging.
- Stop use immediately if you experience any discomfort or pain.
Package Contents
Ensure all items are present in your package:
- Main Control Unit (battery model)
- Power Supply (AC adapter)
- Leg Attachments (2 pcs, XXL Size or Standard Size depending on selection)
- Hose (connects the control unit to the attachments)
Product Overview
Control Unit
The main control unit features an intelligent touchscreen display and buttons for easy operation. It allows you to adjust time, pressure, and select massage modes.
Leg Attachments
The leg attachments are made from premium materials and feature overlapping zones for gapless compression. They are available in XXL and Standard sizes.
Size Charts
Setup Instructions
- Charge the Control Unit: Connect the power supply to the control unit and plug it into a power outlet. A full charge takes approximately 2 hours. The unit can be used for 2 to 2.5 hours in B mode with continuous work on a full charge.
- Connect Hoses: Connect the hose from the control unit to the leg attachments. Ensure the connections are secure to prevent air leakage.
- Wear Leg Attachments: Put on the leg attachments. Ensure they fit snugly but comfortably around your legs. The overlapping zones are designed for gapless compression.
Operating Instructions
- Power On: Press the ON/PAUSE button on the control unit to turn on the device. The display will light up.
- Set Time: Use the '+' and '-' buttons next to 'Time' to adjust the massage duration. The working time can be set from 10 to 90 minutes.
- Set Pressure: Use the '+' and '-' buttons next to 'Press' to adjust the compression intensity. The pressure range is 30 mmHg to 260 mmHg.
- Select Mode: Choose one of the four automatic working modes (A, B, C, D) by pressing the corresponding mode button.
- Mode A (Pneumatic compression massage with balloon alone): Individual chambers inflate and deflate sequentially.
- Mode B (Balloon Sequence All Inflatable Extrusion Massage): All chambers inflate and deflate in a sequence, providing a continuous extrusion massage.
- Mode C (1+2, 3+4, 5+6 Sequential massage of two balloons): Pairs of chambers inflate and deflate sequentially.
- Mode D (Pneumatic bags were massaged together): All chambers inflate and deflate simultaneously.
- Customize Chambers: You can customize individual chambers (1-6) to give extra attention to specific areas. Refer to the control panel for individual chamber controls.
- Start/Pause: Press the ON/PAUSE button to start or pause the massage session.
- Power Off: Press and hold the ON/PAUSE button to turn off the device after use.
Maintenance
- Cleaning: Disconnect the device from power before cleaning. Wipe the control unit and leg attachments with a soft, damp cloth. Do not use abrasive cleaners or immerse the unit in water.
- Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures. Ensure the hoses are not kinked during storage.
- Battery Care: To prolong battery life, avoid fully discharging the unit frequently. Charge it regularly, even if not in use for extended periods.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not turn on | Battery is low or depleted; Power cable not connected properly. | Charge the control unit. Ensure the power cable is securely connected. |
| No compression or weak compression | Hoses are not securely connected; Hoses are kinked; Leg attachments are not properly worn. | Check all hose connections. Ensure hoses are not bent or kinked. Adjust leg attachments for a snug fit. |
| Uneven compression | Leg attachments are not evenly worn; Internal air chambers may be obstructed. | Re-adjust leg attachments. Check for any foreign objects inside the chambers. |
| Device stops unexpectedly | Battery is low; Session time has ended. | Recharge the battery. Check the set massage duration. |
Specifications
| Attribute | Value |
|---|---|
| Brand Name | VamsLuna |
| Item Type | Massage & Relaxation |
| Product Name | Pneumatic leg |
| Product Type 1 | Lymphatic drainage massager |
| Product Type 2 | Compression massager |
| Feature 1 | Professional Presotherapy |
| Feature 2 | Air wrap |
| Function 1 | Increases circulation, reduces pain and soreness |
| Function 2 | Rechargeable & Portable |
| Chambers | 6 individual chambers |
| AC Input | 100-240V, 50-60Hz |
| AC Output | 12.6V/4A |
| Battery | Lithium battery 12V, 5000mAh (Built-in) |
| Pressure Range | 30 mmHg (3.99 kPa) - 260 mmHg (34.66 kPa) |
| Working Noise | ≤60dB(A) |
| Working Time | 10 to 90 minutes |
| Voltage | <50V AC |
| Certification | CE |
| Application | Leg |
| Material | Composite Material |
| Origin | Mainland China |
| Batteries Included | Yes |
| Electronic | Yes |
User Tips
- Targeted Massage: Utilize the individual chamber controls to customize your massage. This allows you to apply extra attention and pressure to specific areas of your legs that need it most.
- Optimal Fit: Ensure the leg attachments are worn correctly and snugly. A proper fit is crucial for effective and even compression across all chambers.
- Regular Use: Consistent use can contribute to better circulation and reduced muscle soreness over time. Incorporate it into your recovery routine.
Warranty and Support
For any questions, technical support, or warranty claims, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.