Wallpad Modular Part

Wallpad Modular Wall Light Switch Instruction Manual

Model: Modular Part

Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your Wallpad Modular Wall Light Switch. These switches are designed for modern electrical systems, offering various configurations including 12V/24V DC Dry Contact, 12V/24V DC RS485, and AC110-220V models, all featuring LED indicators.

Wallpad Modular Switches with LED Indicators (1-4 Gang)
Figure 1: Various Wallpad Modular Switch Modules with LED Indicators (1-4 Gang options).

Safety Information

Always ensure power is disconnected before installation or maintenance. Installation should be performed by a qualified electrician in accordance with local electrical codes. Do not connect 220V power to communication ports on RS485 modules.

Product Features

  • Hotel Design Switch aesthetics.
  • Available in three power types: AC110-220V RS485 Modbus, DC12V 24V Dry Contact, and DC12V 24V RS485.
  • Integrated LED indicators for both the outline and the icon on the button.
  • Customizable button icons (contact manufacturer for details).
  • RS485 models require a controller for operation.
  • AC110-220V type switches can be connected for 2-way functionality using AB wires.

Setup and Installation

The Wallpad Modular Switch system consists of individual modules, frames, and mounting boxes, which are sold separately. Ensure you have all necessary components before beginning installation.

1. Component Overview

Exploded View of Wallpad Modular Switch Components
Figure 2: Exploded view showing the Frame, Module, Screws, Mid Steel Panel, and Back Box.

The system comprises a back box, a mid steel panel, the switch module, and a decorative frame. These components are assembled together to form the complete switch unit.

2. Mounting Box Selection

Only square mounting boxes are compatible with this product. Round boxes are not suitable. The number of mounting boxes required depends on the frame size:

  • 1 frame: 1 piece of box
  • 2 frames: 2 pieces of box
  • ...and so on, up to 5 frames requiring 5 pieces of box.

Square boxes can be connected to each other for multi-gang installations.

Mounting Box Options for Wallpad Modular Switches
Figure 3: Examples of 86-type and 146-type mounting boxes. The 86-type box has a screw hole distance of 60mm, and the 146-type box has a screw hole distance of 120mm.

For 86*86mm panels, use an 86 Type Box (Screw Hole Distance 60mm). For 146*86mm panels, use a 146 Type Box (Screw Hole Distance 120mm).

3. Wiring Instructions

Refer to the specific wiring diagrams for your module type (AC110-220V, DC Dry Contact, or DC RS485) below. Always ensure power is OFF before wiring.

3.1. DC12V/24V Dry Contact Module Wiring

Rear View of DC12V 24V Dry Contact Module with Wiring Terminals
Figure 4: Wiring diagram for DC12V/24V Dry Contact Module. Key terminals are: DC (for indicator common terminal), GND (for indicator negative terminal), KC (for buzzer common terminal), and dry contact terminals for switching.

Connect the DC power supply and control lines according to the labels. The "DC" terminal is for the common positive of the indicator light, "GND" is for the negative of the indicator light, and "KC" is for the common terminal of a buzzer (if applicable). The switch operates as a dry contact.

3.2. AC110-220V Module Wiring

Rear View of AC110-220V Module with Wiring Terminals and Specifications
Figure 5: Wiring diagram for AC110-220V Module. Connect Live (火线) and Neutral (零线) wires. Output terminals are L1, L2, L3, L4. The communication port should NOT be connected to 220V power.

Connect the Live (火线) and Neutral (零线) wires to the designated terminals. The output terminals are labeled L1, L2, L3, L4. For 2-way switching, two AC110-220V type switches can be connected using AB wires. Important: Do not connect 220V power to the communication port.

3.3. DC12V/24V RS485 Module Wiring

Rear View of DC12V 24V RS485 Module with Wiring Terminals
Figure 6: Wiring diagram for DC12V/24V RS485 Module. Connect DC power and RS485 communication lines. Key terminals are: DC (for indicator common terminal), GND (for indicator negative terminal), KC (for buzzer common terminal), and RS485 communication port. Do not connect 220V power to the communication port.

Connect the DC power supply and RS485 communication lines. The "DC" terminal is for the common positive of the indicator light, "GND" is for the negative of the indicator light, and "KC" is for the common terminal of a buzzer (if applicable). The RS485 communication port requires connection to a compatible controller. Important: Do not connect 220V power to the communication port.

4. Assembly Steps

  1. Ensure all wiring is complete and secure within the mounting box.
  2. Attach the mid steel panel to the mounting box using screws.
  3. Carefully align and insert the switch module(s) into the mid steel panel.
  4. Secure the decorative frame over the module(s) and mid steel panel.
  5. Restore power and test the switch functionality.

Operating Instructions

The Wallpad Modular Switches are designed for intuitive operation with a gentle click mechanism and clear LED indicators.

Video 1: Demonstration of Wallpad Hotel Switch operation, showcasing the gentle click button and soft LED indicator backlight in orange and white outline.
  • Gentle Click Button: Press the button gently to activate or deactivate the connected circuit.
  • LED Indicator: The integrated LED indicator provides visual feedback on the switch status. Depending on the model, this can be an orange icon backlight or a white outline backlight.
  • RS485 Control: For RS485 models, the switch is controlled via a connected RS485 controller. Refer to your controller's manual for specific programming and operation details.
  • 2-Way Switching: If configured for 2-way operation with two AC110-220V switches, pressing either switch will toggle the circuit.

Maintenance

To ensure the longevity and proper functioning of your Wallpad Modular Switch, follow these simple maintenance guidelines:

  • Cleaning: Use a soft, dry cloth to clean the surface of the switch and frame. Avoid abrasive cleaners, solvents, or excessive moisture, as these can damage the finish or internal components.
  • Inspection: Periodically check for any loose connections or signs of wear. If any damage is observed, disconnect power and consult a qualified electrician for repair or replacement.
  • Environmental Conditions: Ensure the switch is installed in an environment within its specified operating temperature and humidity ranges to prevent malfunction.

Troubleshooting

If you encounter issues with your Wallpad Modular Switch, try the following troubleshooting steps:

ProblemPossible CauseSolution
Switch not respondingNo power, loose wiring, faulty module.Check circuit breaker. Verify all wiring connections are secure (ensure power is off). Test with a known working module if available.
LED indicator not lighting upIncorrect wiring of LED terminals, faulty LED.Review wiring diagram for LED connections (DC and GND terminals). Ensure correct voltage is applied.
RS485 module not communicatingIncorrect RS485 wiring, controller issue, incorrect address.Verify RS485 A/B wire connections. Check controller settings and address configuration. Consult controller manual.
Switch feels loose in frameModule not properly seated or screws not tightened.Ensure module is fully clicked into the mid steel panel and the frame is securely attached.

If the problem persists after attempting these solutions, please contact customer support or a qualified electrician.

Specifications

FeatureDetail
Model NumberModular Part
Brand NameWallpad
Product SeriesS6 Series
OriginMainland China
CertificationCE, CCC, CQC, RoHS
Inner MaterialHigh Phosphorus Copper and Silver contact point
Self Consuming PowerLess than 0.1mW
Voltage (AC Module)110V-250V
Rated Current (AC Module)10A
Rated Power (AC Module)1000W
Mechanical Life300,000 Times Of Operation
Dimensions52*52mm (Module Size)
Power TypesAC110-220V RS485 Modbus, DC12V 24V Dry Contact, DC12V 24V RS485

User Tips

  • Professional Installation Recommended: Due to the electrical nature of this product, professional installation by a certified electrician is highly recommended to ensure safety and proper functionality.
  • Compatibility Check: Before purchasing, ensure the chosen module type (AC, Dry Contact, or RS485) is compatible with your existing electrical system and control setup.
  • Custom Icons: If you require custom icons for your switch buttons, contact Wallpad Official Store directly for customization options.
  • RS485 System Integration: For RS485 modules, plan your smart home system integration carefully. Ensure your RS485 controller is properly configured to communicate with the switch modules.

Warranty and Support

Wallpad products come with a comprehensive warranty and support:

  • Warranty: All products have a 1-year warranty from the date of purchase.
  • Quality Issues: Enjoy 7 days to return if any quality problems are encountered.
  • Customer Service: All emails will be answered within 24 hours.

For further assistance, please contact Wallpad Official Store customer service.


Wallpad Modular Hotel Wall Switch and Outlet System Feature Demo

Wallpad Modular Hotel Wall Switch and Outlet System Feature Demo

0:32 • 1280×720 • feature_demo

Related Documents - Modular Wall Switch System

Preview Light Switch Wiring Configurations: 1 Way, 2 Way, and Intermediate
Detailed guide to understanding and implementing 1-way, 2-way, and intermediate wiring configurations for light switches, including textual descriptions of diagrams and components.
Preview Home Use 86-type Wall Mount Box Installation Instructions
Detailed installation instructions for the Home Use 86-type Wall Mount Box by WenZhou Wallpad Electric Co.,LTD, covering concealed and surface-mounted methods, safety precautions, and product limitations.
Preview Wallpad European Standard Switches & Sockets User Manual
Comprehensive user manual for Wallpad European Standard Switches & Sockets, covering safety information, product overview, technical specifications, installation instructions, operation, maintenance, compliance, and warranty.
Preview Scimagic-RC Ewelink Smart Switch - User Manual & Setup Guide
User manual for the Scimagic-RC Ewelink Smart Switch, a 1-channel Wifi inching relay automation module. This guide covers setup, connecting to the Ewelink app, and device control for models compatible with DC 5V, 12V, 24V, 32V, 110V, 220V, and Alexa.
Preview Latitude Run® Amold 155'' L-Shaped Sectional Sofa Assembly Instructions
Comprehensive assembly guide for the Latitude Run® Amold 155'' L-Shaped Sectional Sofa. This manual provides step-by-step instructions, a detailed parts list, hardware identification, and textual descriptions of diagrams to help you assemble your 8-seater modular living room couch.