1. Introduction

This PowMr Hybrid Solar Inverter is a multi-function inverter/charger, combining the functions of an inverter, solar charger, and battery charger to provide uninterruptible power support in a portable size. The POW-HVM3.2H-24V-N model is an all-in-one inverter that offers a pure sine wave inverter output and bypass output with a maximum power capacity of 3000W.

It features a rated output voltage of 230V and supports a maximum charging current of 80A for both solar charging and AC power charging. This inverter is suitable for various lithium-ion and lead-acid battery systems with a 24V voltage rating. With a wide MPPT voltage range of 30-400V and a maximum PV input power of 3000W, it ensures efficient energy conversion. The inverter includes multiple protection features to ensure the stability of system operation.

PowMr 3.2KW 24V Hybrid Solar Inverter with key specifications
PowMr 3.2KW 24V Hybrid Solar Inverter Overview
Product Unboxing and Feature Overview

2. Key Features

  • Pure sine wave inverter output.
  • User-configurable input voltage range for home appliances and personal computers via LCD settings.
  • Configurable battery charging current based on applications via LCD settings.
  • Configurable AC/Solar Charger priority via LCD settings.
  • Compatible with mains voltage or generator power.
  • Auto restart function when AC power recovers.
  • Built-in overload, over-temperature, and short-circuit protection.
  • Smart battery charger design for optimized battery performance.
  • Cold start function.
  • Optional WIFI/GPRS module for remote monitoring.
  • Supports connection to various battery types, including lithium batteries.

3. Setup and Installation

Before installation, ensure the inverter is placed in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Mount the inverter securely to a wall or stable surface.

3.1 Connection Diagram

The inverter supports a hybrid power system configuration, allowing connection to solar panels, a battery bank, a generator or utility grid, and home appliances.

Hybrid Power System Diagram showing connections for solar, generator/utility, battery, and home appliances
Hybrid Power System Connection Overview

3.2 Terminal Connections

Carefully connect the following components to the inverter's terminals:

  • PV IN: Connect your solar panel array to these terminals. Ensure the PV array MPPT voltage range is between 30-400Vdc and the maximum PV input power does not exceed 3000W.
  • BATTERY: Connect your 24V battery bank (Lithium, Flooded, AGM, Gel, Sealed Lead Acid) to these terminals. Observe correct polarity (+ and -).
  • AC IN: Connect the utility grid or generator power to these terminals.
  • AC OUT: Connect your household appliances or load to these terminals.
  • COMM: This port is for the optional WiFi module for remote monitoring.
Rear panel of the inverter showing AC IN, AC OUT, Battery, and PV IN terminals
Inverter Rear Panel Connections

3.3 Battery Compatibility

The inverter is designed to work with various 24V battery types, including:

  • LiFePO4 Batteries
  • AGM Batteries
  • Lithium Batteries
  • Flooded Batteries
  • Sealed Lead Acid Batteries
  • Gel Batteries
Diagram showing various compatible battery types: LiFePO4, AGM, Lithium, Flooded, Sealed Lead Acid, Gel
Compatible Battery Types

4. Operation

The inverter features a comprehensive LCD display and user-friendly buttons for configuration and monitoring.

4.1 LCD Display and Buttons

The LCD display provides real-time information on system status, battery charging current, AC/solar charger priority, and input voltage. Use the buttons to navigate menus and adjust settings according to your application needs.

Front panel of the inverter with LCD display and control buttons
Inverter Front Panel with LCD and Controls

4.2 WiFi Monitoring (Optional)

The inverter is WiFi monitoring ready. An optional WiFi module can be connected to the COMM port to allow real-time performance monitoring and parameter changes via a mobile application, eliminating the need to check the controller's LCD directly.

Diagram showing the optional WiFi module connection for remote monitoring via a smartphone app
Optional WiFi Monitoring Setup

5. Maintenance

Regular maintenance ensures optimal performance and longevity of your inverter. Always disconnect all power sources (PV, battery, AC input) before performing any maintenance.

  • Cleaning: Keep the inverter's exterior clean and free from dust. Use a dry cloth for cleaning. Do not use liquid cleaners.
  • Ventilation: Ensure the ventilation openings are clear and not obstructed to prevent overheating.
  • Connections: Periodically check all electrical connections (PV, battery, AC input/output) for tightness and signs of corrosion.
  • Environment: Maintain the operating environment within the specified temperature and humidity ranges.

6. Troubleshooting

This section addresses common issues and their potential solutions.

6.1 Common Issues & Solutions

  • Inverter not turning on: Check battery connections and voltage. Ensure the main power switch is on. Verify AC input if operating in utility mode.
  • No output power: Check AC output connections. Verify for overload or short circuit conditions. The inverter has overload/short circuit protection and may shut down.
  • Battery not charging: Check solar panel connections and ensure sufficient sunlight. Verify AC input if charging from utility. Check battery charging current settings on the LCD.
  • Excessive fan noise: Fans operate to cool the inverter, especially under heavy load or high ambient temperatures. If noise is unusually loud or constant without load, check for obstructions in the fan vents.
  • WiFi module not detected/working: Ensure the optional WiFi module is correctly installed in the COMM port. Check the module's indicator lights and refer to the WiFi module's specific instructions for setup and app connectivity.

7. Specifications

7.1 General Product Specifications

AttributeValue
Brand NamePowMr
Model NumberPOW-HVM3.2H-24V-N
Rated output power3.2KW/3KVA
Output Power1 - 200 KW
Output Voltage230VAC
Output CurrentMPPT 80A
Output TypeSINGLE
Output Frequency50Hz/ 60Hz (Auto-detection)
Output Voltage WaveformPure Sine Wave
Battery Voltage24VDC
Maximum PV input power3000W
PV Array MPPT Voltage Range30VDC-400VDC
Size348X270X95mm
Weight5.8kg
Is Smart DeviceYes
CertificationCE
System ConfigurationHybrid Solar Inverter
ApplicationHome solar system
FeatureBuild In MPPT Solar Charge Controller
Product TypeMPPT Solar Inverter
Battery Type 1Lithium Batteries, Flooded Batteries, Gel Batteries, User Mo
Battery Type 2Lead-acid Batteries, AGM Batteries
Load typeHousehold appliances, farm tools, farm tools

7.2 Detailed Technical Specifications

INVERTER MODELPOW-HVM2H-12V-NPOW-HVM3.2H-24V-N
Rated Output Power2000VA/1600W3200VA/3000W
Output Voltage WaveformPure Sine Wave
Output Voltage Regulation230Vac±5%
Utility Charging Mode
INVERTER MODEL2KW 12V3.2KW 24V
Charging Algorithm3-Step
AC Charging Current (Max)60 Amp
Bulk Charging Voltage
INVERTER MODEL2KW 12V3.2KW 24V
Flooded Battery14.629.2
AGM / Gel Battery14.128.2
Floating Charging Voltage13.5Vdc27.0Vdc
MPPT Solar Charging Mode
Max. PV Array Power2000W3000W
Nominal PV Voltage240Vdc
PV Array MPPT Voltage Range30~400Vdc
Max. PV Array Open Circuit Voltage400Vdc
Max Charging Current (AC charger+solar charger)80Amp
INVERTER MODEL2KW 12V3.2KW 24V
Safety CertificationCE
Operating Temperature Range-10±C to 50±C
Storage temperature-15±C~ 60± C
Humidity5% to 95% Relative Humidity (Non-condensing)
Input Voltage WaveformSinusoidal (utility or generator)
Nominal Input Voltage230Vac
Low Loss Voltage170Vac±7V (UPS); 90Vac±7V (Appliances)
Low Loss Return Voltage180Vac±7V (UPS); 100Vac±7V (Appliances)
High Loss Voltage280Vac±7V
High Loss Return Voltage270Vac±7V
Max AC Input Voltage300Vac
Nominal Input Frequency50Hz/ 60Hz (Auto-detection)
Low Loss Frequency40±Hz
Low Loss Return Frequency42±Hz
High Loss Frequency65±Hz
High Loss Return Frequency63±Hz
Output Short Circuit ProtectionCircuit Breaker
Efficiency (Line Mode)>95% (Rated R load, battery full charged)
Transfer Time10ms typical (UPS); 20ms typical (Appliances)
INVERTER MODEL2KW 12V3.2KW 24V
Output Frequency50Hz/ 60Hz (Auto-detection)
Peak Efficiency0.94
Overload Protection5s@ >150% Io ad; 10s@ 110% ~ 150% Io ad
Surge Capacity2* rated power for 5 seconds
Nominal DC Input Voltage12Vdc24Vdc
Cold Start Voltage11.5Vdc23.0Vdc
Low DC Warning Voltage
@ Io ad < 50%11.0Vdc22.0Vdc
@ load >50%10.5Vdc21.0Vdc
Low DC Warning Return Voltage
@ load < 50%11.5Vdc22.5Vdc
@ load >50%11.0Vdc22.0Vdc
Low DC Cut off Voltage
@ load < 50%10.2Vdc20.5Vdc
@ load >50%9.6Vdc20.0Vdc
High DC Recovery Voltage14.0Vdc32Vdc
High DC Cut-off Voltage16.0Vdc33Vdc
No Load Power Consumption<25W<35W
Detailed technical specifications table for PowMr HVM2H-12V-N and HVM3.2H-24V-N inverters
Detailed Technical Specifications (Image Reference)

8. User Tips

  • Optional WiFi Module: The WiFi module is an optional accessory and may not be included in all packages. If you intend to use remote monitoring, ensure you purchase the module separately if it's not bundled.
  • Battery-less Operation: This hybrid inverter is designed to work with batteries. While some hybrid inverters can operate without batteries under specific conditions (e.g., direct solar to load), always consult the full user manual for detailed information on battery-less operation modes and limitations to avoid damage.
  • Wire Gauge: For safe and efficient operation, always use the recommended wire gauges for battery and PV connections. Refer to the complete user manual for specific wire size recommendations based on current and distance. For the 3000W inverter, ensure battery terminals can accommodate appropriate heavy-gauge wiring (e.g., 2AWG or larger, depending on current draw).
  • Grid-Tied vs. Off-Grid: This is a hybrid inverter, meaning it can integrate with both solar and utility/generator power. It can supply power to connected devices from solar, battery, or utility. For specific grid-tied functionalities (e.g., feeding excess power back to the grid) or advanced 'mixing' functions (simultaneous use of solar and grid without batteries), consult the detailed manual and local regulations.
  • Fan Operation: The inverter's fans will activate to dissipate heat, especially during high load or charging cycles. This is normal operation. If you experience excessive or unusual noise, ensure proper ventilation and check for any obstructions.

9. Warranty and Support

The PowMr POW-HVM3.2H-24V-N Hybrid Solar Inverter comes with a 1-year warranty from the date of purchase. This warranty covers manufacturing defects and malfunctions under normal operating conditions.

For technical support, troubleshooting assistance, or warranty claims, please contact PowMr customer service through their official channels. Ensure you have your product model number and purchase details available when contacting support.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.