1. Introduction

The KKMOON KKM198 Smart Digital Multimeter is a versatile and user-friendly instrument designed for various electrical measurements. It features a 4.4-inch EBTN backlight LCD display, touch buttons, and advanced functions like VFC (Voltage Frequency Converter) for accurate readings in variable frequency environments. This manual provides detailed instructions for safe and effective use of your multimeter.

KKMOON KKM198 Smart Digital Multimeter front view

Figure 1: KKM198 Smart Digital Multimeter

2. Package Contents

  • 1 x KKM198 Smart Digital Multimeter
  • 1 x User Manual
  • 1 x Pair of Test Leads (Pens)
  • 1 x K-type Temperature Probe
Package contents of KKMOON KKM198 Multimeter

Figure 2: Multimeter and included accessories

3. Setup

3.1 Battery Installation

The KKM198 multimeter requires 2 x AAA batteries (not included). To install or replace batteries:

  1. Ensure the multimeter is powered off and disconnect all test leads from the device and any circuits.
  2. Locate the battery compartment on the back of the multimeter.
  3. Open the battery compartment cover.
  4. Insert two AAA batteries, observing the correct polarity (+/-).
  5. Close the battery compartment cover securely.

WARNING: To avoid electrical shock, remove test leads before replacing batteries or opening the case.

Back of the multimeter showing battery compartment warning

Figure 3: Battery compartment and warning label

3.2 Connecting Test Leads

Connect the red and black test leads to the appropriate input jacks on the multimeter. The multimeter features an Input Jack Indicator:

  • When the measurement function (gear) is changed, the corresponding input jack light will flash for 5 times.
  • This prompts you to insert the probe into the correct jack for the selected measurement, helping to avoid wrong connections and potential damage.
Input Jack Indicator on KKM198 Multimeter

Figure 4: Input Jack Indicator for correct probe connection

Video 1: Product display and demonstration of automatic identification mode, voltage, resistance, buzzer, NCV, and capacitance measurements.

4. Operating Instructions

The KKM198 features an intuitive interface with touch buttons and an automatic identification mode for ease of use.

4.1 Power On/Off

  • To power on the multimeter, press and hold the POWER button.
  • To power off, press and hold the POWER button again.
  • The device also features an automatic shut-down function to conserve battery life.

4.2 Automatic Identification Mode (Auto Smart Mode)

In "Auto" mode, the multimeter automatically identifies the type of measurement (voltage, resistance, continuity) and selects the best resolution. This simplifies operation, especially for beginners.

Multimeter display showing Auto Smart Mode

Figure 5: Auto Smart Mode display

4.3 Measurement Functions

The KKM198 supports a wide range of measurements. Use the touch buttons to switch between functions or rely on the automatic identification mode.

  • AC/DC Voltage: Measures alternating and direct current voltage.
  • AC/DC Current: Measures alternating and direct current.
  • Resistance (Ω): Measures electrical resistance.
  • Capacitance (F): Measures capacitance.
  • Diode: Tests diodes for functionality.
  • Continuity (Buzzer): Checks for electrical continuity with an audible beep.
  • Frequency (Hz)/Duty Cycle: Measures frequency and duty cycle.
  • NCV (Non-Contact Voltage): Detects AC voltage without direct contact.
  • VFC (Voltage Frequency Converter): Provides accurate voltage readings in variable frequency environments, such as those found in motor drives or inverters. This function helps overcome the inaccuracies of traditional multimeters when measuring non-sinusoidal waveforms.
  • Temperature (TEMP): Measures temperature using the included K-type temperature probe.
  • Zero/Line Test: For identifying live and neutral wires.
  • Data Hold (HOLD): Freezes the current reading on the display.
  • Flashlight: Illuminates the work area.
Icons representing various functions of the KKM198 Multimeter

Figure 6: KKM198 Multimeter function icons

Comparison of touch screen multimeter vs traditional multimeter

Figure 7: Touch screen operation vs. traditional rotary switch

Multimeter measuring temperature with K-type probe

Figure 8: Temperature measurement using the K-type probe

Multimeter demonstrating NCV (Non-Contact Voltage) detection

Figure 9: NCV (Non-Contact Voltage) detection

5. Maintenance

5.1 Cleaning

Wipe the multimeter casing with a damp cloth and mild detergent. Do not use abrasives or solvents. Ensure the device is completely dry before use.

5.2 Storage

When not in use for extended periods, remove the batteries to prevent leakage. Store the multimeter in a cool, dry place, away from direct sunlight and extreme temperatures.

6. Troubleshooting

  • No Display/Low Battery: Check battery installation and replace with fresh AAA batteries if the low battery indicator is shown or the display is dim.
  • "OL" on Display: This indicates an overrange condition, meaning the measured value exceeds the maximum range of the selected function.
  • Incorrect Readings for Variable Frequency: Ensure the VFC function is activated when measuring voltage or frequency in circuits with variable frequency drives (e.g., motor RPM). Traditional multimeters may give unstable or incorrect readings in such scenarios.
  • Continuity Buzzer: If the continuity buzzer is not desired, consult the full user manual for options to disable or adjust audible alerts, if available.

7. Specifications

FeatureSpecification
Brand NameKKMOON
Model NumberKKM198
Is Smart DeviceNo
Operating ModeAuto/Manual
Display TypeDigital Display (4.4 inch EBTN Backlight LCD)
Sampling RateAbout 3 times per second
AC Voltage Range2V/20V/200V/750mV
DC Voltage Range6V/60V/600V/1000V
AC Current Range600mA±(1.2%+10)
DC Current Range600mA±(1.2%+10)
Measuring Resistance Range600Ω/6kΩ/60kΩ/600kΩ/6MΩ/60MΩ
Measuring Capacitance Range10nF/100nF/1uF/10uF/100uF/1mF/10mF/60mF
Measuring Inductance RangeDo not test inductance
Diode Test1mA 3V
Temperature TestYES (K-type probe included, -20~1000℃ / 0~1832°F)
NCV (Non-Contact Voltage)YES
VFC FunctionYES
Touch ButtonYES
Flashlight LightingYES
Automatic Shut DownYES
Low Battery IndicatorYES
Operating Temperature0 - 40 ℃
Relative Humidity<80%
Power Supply2 * AAA batteries (NOT INCLUDED)
Dimensions140mm x 70mm x 22mm
WeightAbout 150g (including battery)
CertificationCE
Detailed specifications table for KKM198 Multimeter

Figure 10: Detailed Specifications

8. User Tips

  • The KKM198 includes a K-type thermocouple for temperature measurements, making it a versatile tool for various applications.
  • While the multimeter is compact and portable, a dedicated carrying case is not included in the standard package. Consider acquiring one for protection during transport.
  • Leverage the "Auto Smart Mode" for quick and easy measurements, as it automatically detects the parameter and range.
  • For measurements in environments with variable frequency drives, always utilize the VFC function to ensure accurate readings and avoid common errors associated with non-sinusoidal waveforms.
  • The input jack indicator is a crucial safety feature. Always observe the flashing lights to ensure test leads are connected to the correct ports for the selected measurement.

9. Warranty & Support

For warranty information and technical support, please refer to the official KKMOON website or contact your retailer. Keep your purchase receipt as proof of purchase.