1. Introduction
The KKmoon KKM828 is an intelligent 2-in-1 graphical digital oscilloscope and multimeter designed to enhance work efficiency for various electrical and electronic tasks. It features a high-clarity 2.4-inch color screen, allowing for direct waveform measurement without the need for a separate oscilloscope probe. This device combines the functionalities of a multimeter with the visual capabilities of an oscilloscope, offering fast, accurate measurements and clear waveform displays.
This manual provides essential information for the safe and effective use of your KKM828 device. Please read it thoroughly before operation.
2. Setup
2.1 Unpacking and Inspection
Upon receiving your KKmoon KKM828, carefully unpack the contents and inspect for any damage. The standard package includes:
- 1 x KKM828 Graphical Multimeter Host
- 1 x Pair of Test Pens
- 1 x Protective Bag
- 1 x User Manual
If any items are missing or damaged, please contact your vendor immediately.

2.2 Battery Installation
The KKM828 requires 3 AA batteries (not included). To install the batteries:
- Locate the battery compartment cover on the back of the device.
- Open the cover.
- Insert 3 AA batteries, ensuring correct polarity (+/-).
- Close the battery compartment cover securely.
2.3 Initial Power On
Turn the function dial to any measurement mode (e.g., Voltage) to power on the device. The 2.4-inch color screen will display the interface.

3. Operating Instructions
3.1 Multimeter Functions
The KKM828 offers a comprehensive set of multimeter functions with automatic and manual ranging. Rotate the central dial to select the desired measurement mode.
- AC/DC Voltage: Measure voltage by connecting the test leads to the circuit.
- AC/DC Current: Measure current by connecting the test leads in series with the circuit.
- Resistance: Measure resistance by connecting the test leads across the component.
- Capacitance: Measure capacitance by connecting the test leads across the capacitor.
- Frequency: Measure frequency by connecting the test leads to the signal source.
- Duty Cycle: Measure duty cycle by connecting the test leads to the signal source.
- Diode Test: Test diodes for forward voltage drop.
- Continuity Test: Check for continuity in a circuit with an audible beep.


3.2 Oscilloscope Mode
The KKM828 features a graphical oscilloscope mode for waveform analysis.
- Entering Oscilloscope Mode: In voltage/current gear, long press the 'R' key to enter oscilloscope mode.
- Auto Capture Waveform: Press the 'R' key again to automatically capture the waveform.
- Time Base Setting: Press the 'F1/TIME' key to enter the time base menu. Use 'F2' and 'F3' to adjust the time base.
- Range Setting: Press the 'F2/RANGE' key to enter the range menu. Use 'F2/X1X3' and 'F3/X10' to set the range.
- Trigger Setting: Press the 'F3/TRIG' key to enter the trigger setting menu.
- Rising/Falling Edge: Press 'F2' to switch between rising and falling edges.
- Trigger Mode: Press 'F3/MODE' to switch between trigger modes (Auto, Single, Normal).
- Trigger Level: Press 'F4/LEVEL' to set the trigger level.
- Waveform Display: The color display provides a clear and intuitive waveform.




3.3 Data Storage and Recall
The KKM828 supports mass storage of up to 100 data records and 10 waveforms.
- Saving Waveforms: Long press the 'S' key to enter the database. Press 'F4/SAVE' to save the current waveform.
- Saving Data: Long press the 'S' key to enter the database. Press 'F4/SAVE' to save the current data.
- Locking Data: Press the 'S' key to lock the current data. The small window will display real-time data while the main display shows the locked value.
- Relative Value (REL): Press 'F1/REL' to store the current data as a reference value. This effectively eliminates the influence of lead resistance on the result.
- Max/Min Recording (P-H): Press 'F2/P-H' to record the maximum and minimum data during the measurement process.



3.4 Applications
The KKM828 is suitable for a wide range of applications, including:
- Car maintenance
- Equipment maintenance
- Power system debugging
- Production line testing

3.5 Product Demonstration Video
For a visual guide on operating the KKM828, including oscilloscope settings and various multimeter tests, please refer to the official product demonstration video:
4. Maintenance
4.1 General Care
- Keep the device clean and dry. Use a soft, damp cloth to wipe the exterior. Do not use abrasive cleaners or solvents.
- Avoid exposing the device to extreme temperatures, humidity, or direct sunlight.
- Store the device in its protective bag when not in use to prevent scratches and dust accumulation.
- If the device will not be used for an extended period, remove the batteries to prevent leakage.
4.2 Fuse Replacement
The KKM828 features triple safety with double insurance tubes (500mA/250V and 10A/250V). If a fuse blows, it must be replaced with a fuse of the same type and rating to maintain safety and functionality.

5. Troubleshooting
Here are some common issues and potential solutions:
- Device does not power on: Check battery installation and ensure batteries are not depleted. Replace if necessary.
- Inaccurate readings: Ensure test leads are properly connected and not damaged. Verify the correct measurement mode is selected.
- Beep warning during measurement: The device will emit a beep warning if the input voltage is greater than 24V or if the input is over range. Disconnect immediately and check your circuit and settings to prevent damage.
- Screen display issues: If the screen is dim or unclear, check battery levels. Ensure the device is not exposed to extreme temperatures.
- Oscilloscope waveform not stable: Adjust the trigger settings (mode, level, rising/falling edge) to stabilize the waveform.
If you encounter persistent issues not covered here, please refer to the Warranty/Support section for assistance.
6. Specifications
The following table details the technical specifications of the KKmoon KKM828:

| Feature | Specification |
|---|---|
| Material | ABS |
| Color | Black |
| Display | 320*240 LCM, 2.4 inches, White Backlit |
| Input Resistance | 10MΩ |
| Battery | 3 * AA battery (not included) |
| Power Consumption | About 80mA |
| Use Time (low light) | About 5 hours |
| Data Storage | 100 data records / 10 waveforms |
| Operating Environment | 0~40℃, <75%RH |
| Storage Environment | -10~60℃, <90%RH |
| Bandwidth | ACV/1MHz, ACA/5KHz |
| Max. Real-time Sampling Rate | 2.5Msps |
| Multimeter Measurement | Automatic range + manual range |
| Oscilloscope Secondary Display | VP-P, average value, effective value, frequency, time base, amplitude |
| Measurement Mode | Normal, Automatic |
| Item Size | 160 * 83 * 32mm / 6.3 * 3.3 * 1.3in |
| Item Weight | 195g / 6.9ounce |
| DC Voltage Range | 400mV/4V/40V/400V/1000V (Uncertainty: 0.75% rdg+10dgt) |
| AC Voltage Range | 400mV/4V/40V/400V/750V (Uncertainty: 1.0% rdg+10dgt) |
| DC Current Range | 40mA/400mA/4A/10A (Uncertainty: 1.2% rdg+10dgt) |
| AC Current Range | 40mA/400mA/4A/10A (Uncertainty: 1.5% rdg+10dgt) |
| Resistance Range | 400.0Ω~40.00MΩ (Uncertainty: 1.0% rdg+5dgt) |
| Capacitance Range | 0.1nF~100, 10.00mF (Uncertainty: 2.0% rdg+10dgt) |
| Frequency Range | 5Hz~10MHz (Uncertainty: 1.0% rdg+5dgt) |
| Duty Cycle Range | 0.1%~99.9% (Uncertainty: 1.0% rdg+5dgt) |
| Diode Test | Voltage about 5V, test current about 1.5mA |
| Continuity Test | Judgment resistance about: <50Ω beep |
| Fuse Specifications | 500mA/250V, 10A/250V |
| IS Battery Demountable | Yes |
| High-concerned chemical | None |
| Certification | None |
| Origin | Mainland China |
| DIY Supplies | Electrical |
7. User Tips
- Ergonomic Viewing: Utilize the built-in back bracket, which tilts at 60°, for comfortable viewing during extended use.
- Efficient Waveform Analysis: The KKM828's ability to display historical records and real-time data on the same screen allows for quick comparison and analysis of signal changes.
- Safety First: Always pay attention to the beep warnings for input voltage exceeding 24V or over-range conditions. This helps prevent damage to the device and ensures user safety.
- Quick Oscilloscope Access: Remember that a long press of the 'R' key quickly switches the device into oscilloscope mode from multimeter functions, streamlining your workflow.
8. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact your retailer. Ensure you have your product model (KKM828) and purchase details available when seeking support.