1. Introduction
The PowMr POW-HVM2H-12V-N is a pure sine wave all-in-one solar inverter designed for solar energy storage systems. This multi-function inverter/charger combines the functions of an inverter, solar charger, and battery charger to provide uninterruptible power support in a portable size. It can charge batteries using both solar energy and AC power sources, provide power to the load by inverting solar energy, and support bypass output to ensure a continuous and stable power supply.
It delivers a maximum output power of 1600W at 230V and features a wide MPPT tracking voltage range of 90~430V, allowing for a maximum of 2000W solar input. This versatile unit is compatible with various lithium-ion and lead-acid batteries, operating at a 12V system voltage. It can handle charging currents of up to 80A and incorporates multiple protection features to enhance the stability and user experience of solar energy storage systems.
Video: PowMr 1600W Hybrid Inverter Overview
2. Key Features
- Pure sine wave output for sensitive electronics.
- Configurable input voltage range for home appliances and personal computers via LCD setting.
- Configurable battery charging current based on applications via LCD setting.
- Configurable AC/Solar Charger priority via LCD setting.
- Compatible with mains voltage or generator power.
- Auto restart function when AC power recovers.
- Comprehensive protection against overload, over-temperature, and short circuits.
- Smart battery charger design for optimized battery performance.
- Cold start function.
- Optional WIFI/GPRS module for remote monitoring.
- Compatibility with various battery types including Lithium, Flooded, Lead-acid, and AGM.
3. Specifications
Image: Detailed Specifications Table
| Feature | Specification (1600W-12V Model) |
|---|---|
| Model Number | POW-HVM2H-12V-N |
| Output Power | 1600W (Rated Load) |
| Output Voltage | 230Vac ±5% |
| Output Current (Max) | 80A |
| Output Frequency | 50Hz/60Hz (Auto sensing) |
| Max Solar Panel Input | 2000W |
| PV Array MPPT Voltage Range | 30~400Vdc |
| Max. PV Array Open Circuit Voltage | 400Vdc |
| Nominal DC Input Voltage | 12Vdc |
| Battery Types Supported | Lithium, Flooded, Lead-acid, AGM |
| AC Charging Current (Max) | 60Amp |
| Max Charging Current (AC charger + solar charger) | 80Amp |
| Size (L*W*H) | 348*270*95mm |
| Weight | 6.5KG |
| Certification | CE |
| Operating Temperature Range | -10℃ to 50℃ |
| Storage Temperature Range | -15℃ to 60℃ |
4. Setup and Installation
4.1 Basic System Architecture
The inverter/charger is designed for integration into a solar energy system. A complete running system typically includes:
- The PowMr Hybrid Inverter.
- PV modules (solar panels).
- A battery bank (12V system voltage).
- An optional generator or utility grid connection for AC input.
This inverter can power various home or office appliances, including motor-type loads such as refrigerators and air conditioners. For specific system configurations, it is recommended to consult with a qualified system integrator.

Image: Basic System Architecture
4.2 Connections and Ports
Ensure all connections are secure and correctly polarized before operation. The inverter features clearly labeled terminals for AC input, AC output, battery connections (positive and negative), and PV input from solar panels.

Image: Inverter Connection Ports
4.3 Battery Compatibility
The MPPT charge controller is compatible with a range of 12V batteries. Ensure the correct battery type is selected in the inverter's settings for optimal charging and longevity.

Image: Battery Compatibility
5. Operating Modes
The inverter offers versatile working modes to customize the priority of power inputs and outputs, allowing for efficient power management tailored to your energy consumption needs.
5.1 Charging Modes
- Only Solar: Charges batteries exclusively from solar panels.
- Mains First: Prioritizes charging from the AC utility/generator.
- Solar First: Prioritizes charging from solar panels, supplementing with AC if solar is insufficient.
- Mains & Solar: Charges from both AC and solar simultaneously.
5.2 Output Modes
- Solar First: Prioritizes power to loads from solar, then battery, then AC utility/generator.
- Utility First: Prioritizes power to loads from AC utility/generator, then solar, then battery.

Image: Versatile Working Modes
6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your PowMr Hybrid Inverter.
- Cleaning: Keep the inverter's exterior clean and free from dust. Ensure ventilation openings are unobstructed.
- Connections: Periodically check all electrical connections (AC input/output, battery, PV) for tightness and signs of corrosion.
- Ventilation: Ensure the inverter is installed in a well-ventilated area to prevent overheating. The intelligent fans help manage internal temperature.
- Battery Health: Monitor your battery bank's health according to the battery manufacturer's guidelines. The inverter's smart charger design optimizes battery performance.
- Firmware: If equipped with the optional WIFI module, check for available firmware updates to ensure the latest features and bug fixes.
7. Troubleshooting
If you encounter issues with your inverter, consider the following common troubleshooting steps:
- No Power Output: Check AC input and output connections, battery connections, and ensure the inverter is turned on. Verify battery voltage is within the operating range.
- No Solar Charging: Ensure PV panels are connected correctly and receiving sufficient sunlight. Check PV input voltage and current on the LCD display. Verify the MPPT tracking range (30-400Vdc).
- Overload Warning: Reduce the load connected to the inverter. The unit has overload protection and may shut down to prevent damage.
- Over-temperature Warning: Ensure adequate ventilation around the inverter. Clear any obstructions from the cooling fans. Allow the unit to cool down.
- Short Circuit: Immediately disconnect all loads and check for any short circuits in your wiring or connected appliances. The inverter has short circuit protection.
- Battery Not Charging: Check battery connections and ensure the correct battery type is selected in the settings. Verify AC input (if charging from utility) or PV input (if charging from solar).
For persistent issues, please contact PowMr customer support.
8. User Tips
- Battery Selection: Always select the battery type that matches your installed battery bank in the inverter's settings to ensure proper charging and prevent damage.
- Monitor LCD: Regularly check the comprehensive LCD display for system status, charging current, and any warning messages. This helps in proactive maintenance and troubleshooting.
- Optimal Placement: Install the inverter in a cool, dry, and well-ventilated location to maximize its lifespan and efficiency. Avoid direct sunlight or enclosed spaces.
- Load Management: Be mindful of the total power consumption of your connected appliances to avoid overloading the inverter, especially with motor-type loads that have high startup currents.
9. Warranty and Support
The PowMr Hybrid Inverter is CE certified, indicating compliance with European safety, health, and environmental protection requirements.
For any technical assistance, warranty claims, or further inquiries, please contact your seller or PowMr customer support directly. Ensure you have your product model number (POW-HVM2H-12V-N) and purchase details available when seeking support.