1. Introduction
This manual provides comprehensive instructions for the installation, operation, and maintenance of the SUSWE 820 Variable Frequency Drive (VFD). This device is designed to convert single-phase 220V input power into three-phase 220V output, enabling precise control over three-phase AC motors. It is suitable for applications requiring motor fan speed regulation, constant pressure water supply by water pump, and general energy-saving motor control.
Key Features:
- Vector overload type for enhanced motor control.
- Output power options: 750W (0.75KW) and 1500W (1.5KW).
- Output Frequency range: 1.0-99.0Hz.
- Built-in radiator for efficient heat dissipation.
- Compact design for easy integration.
2. Safety Information
Please read and understand all safety warnings and instructions before installing, operating, or performing maintenance on the VFD. Failure to comply with these instructions may result in electric shock, fire, serious injury, or death.
- Ensure the power supply is disconnected before any wiring or maintenance work.
- Only qualified personnel should install and service this equipment.
- Verify correct voltage and current ratings for the VFD and motor.
- Do not touch electrical components when power is applied.
- Ensure proper grounding of the VFD and motor.
- Keep the VFD away from moisture, dust, and corrosive environments.
- Do not operate the VFD with damaged cables or terminals.
3. Product Overview
3.1. Dimensions
The SUSWE 820 VFD features a compact design. Refer to the diagram below for detailed dimensions.

3.2. Control Panel Layout
The front panel provides all necessary controls and indicators for operation and parameter setting.

3.3. Key Descriptions
The following table details the function of each key on the control panel:

- MODE key: View set frequency (Fxxx), operating frequency (Hxxx), operating current (Axxx), motor direction (FWD/REV), input voltage (Uxxx), inverter temperature (Txxx), input point status (Lxxx), PID parameter display (X.X-X X), and setpoint/feedback value.
- ▲ (UP) key: Add function when setting data or add frequency when frequency is controlled by panel.
- ▼ (DOWN) key: Subtract data function when setting data or reduce frequency when frequency is controlled by panel.
- ENTER key: Press to enter parameter mode when setting Pxxx parameters, and press again to save parameters after modification.
- JOG key: Initiates jog operation function.
- RUN key: Starts inverter panel operation.
- STOP / RESET key: Stops operation mode and clears fault alarm function in fault display mode.
- ENTER +: Composite key. In panel lock mode, press this key to unlock the function. When panel lock is enabled, press this key to enter panel lock function.
Description of panel settings: When the panel displays Pxxx, use the UP and DOWN arrow buttons to adjust the specified parameter number, then press ENTER to enter the data mode of this menu item. Data can be modified to the specified size according to the table. After modification, press ENTER to save. If the panel does not display Pxxx mode, press the MODE key until Pxxx is displayed.
4. Setup (Installation and Wiring)
4.1. Mounting
The VFD is designed for panel mounting. Ensure adequate ventilation around the unit. The recommended opening size for installation is 52.5mm x 80mm x 130mm.
4.2. Wiring
All wiring must be performed by a qualified electrician. Ensure the power supply is disconnected before connecting any wires. Refer to the wiring diagram below for proper connections.


Terminal Descriptions:
- L, N: Single-phase 220V AC input.
- PE: Ground connection.
- U, V, W: Three-phase output to the motor.
- CM, NC, ON: Relay output terminals.
- YO, 12V/P: Multi-function composite output point (YO point is a multi-function composite output point. Only one of brake resistor and general transistor output can be used).
- X0, X1, X2, X3: External sensor inputs.
- 12V, GND, 5V: Power supply for external sensors.
- AI: Analog input (0-5V/0-10V).
- A+, B-: 485 communication interface.
Note: For single-phase three-wire output, connect U, V, W to the motor. For single-phase two-wire output without dismantling, connect U, V to the motor. For encoder input, connect X2, X3, GND, 5V/12V.
5. Operating Instructions
5.1. Basic Operation
- Power On: Connect the VFD to the appropriate single-phase 220V power supply. The display will light up.
- Start Motor: Press the RUN key to start the motor.
- Stop Motor: Press the STOP / RESET key to stop the motor.
- Jog Operation: Press the JOG key for momentary motor operation.
5.2. Frequency Regulation
The VFD features a potentiometer on the front panel for regulating the output frequency. Turn the knob clockwise to increase the frequency and counter-clockwise to decrease it.
5.3. Parameter Settings
To access and modify parameters (Pxxx settings):
- Press the MODE key repeatedly until 'Pxxx' (e.g., P001) is displayed.
- Use the ▲ (UP) or ▼ (DOWN) keys to navigate to the desired parameter number.
- Press the ENTER key to enter the data modification mode for that parameter.
- Use the ▲ (UP) or ▼ (DOWN) keys to adjust the parameter value.
- Press the ENTER key again to save the new value.
- Press MODE to exit parameter setting mode.
6. Maintenance
Regular maintenance ensures optimal performance and longevity of your VFD.
- Cleaning: Periodically clean the VFD's exterior and ventilation openings to prevent dust accumulation, which can hinder heat dissipation. Use a soft, dry cloth. Do not use liquid cleaners.
- Inspection: Regularly check all wiring connections for tightness and signs of wear or damage. Inspect the cooling fan for proper operation and obstructions.
- Environment: Ensure the operating environment remains within specified temperature and humidity ranges.
7. Troubleshooting
The VFD is equipped with fault detection capabilities. If an error occurs, a fault code will be displayed. Refer to the table below for common fault codes and their solutions.

| Alarm Type | Fault Description | Fault Comment |
|---|---|---|
| OC | Instantaneous overcurrent | Check whether the motor is normal |
| OCA | Acceleration overcurrent | Check whether the motor is normal |
| OCD | Deceleration overcurrent | Adjust the acceleration time appropriately |
| OCN | Constant speed overcurrent | Adjust the deceleration time appropriately |
| OU | Overpressure | Check whether the machine is normal and the voltage is stable |
| LU | Undervoltage | Adjust the acceleration and deceleration time properly, and check whether the mains supply is normal (180V-240V) |
| OH | Inverter overheating | Detect whether the mains supply is normal |
| EF | External fault | Detect external sensors. Whether the input is normal |
| ERS | Failure restart failed | Restart the drive |
| LP | Input phase failure | Check whether the mains supply is normal |
| OL1 | Motor overload | Check whether the motor is normal and whether the load is too heavy |
| OL2 | Inverter overload | Check whether the motor is normal and whether it matches the frequency converter power |
| OL3 | Temporary motor overload | Check whether the motor matches the power of the frequency converter |
| OL4 | Temporary overload of frequency converter | Check whether the load matches the motor |
| 485 | Communication failure | Check whether the communication line is normal, and whether the upper computer communication is normal |
| PID | PID failure | Check whether analog input is output and whether sensor is normal |
| NO | No fault alarm | Check whether analog input is output and whether sensor is normal |
8. Specifications
| Attribute | Value |
|---|---|
| Model Number | SUSWE-810 (Note: Product title refers to SUSWE 820) |
| Type | DC/AC Inverters |
| Input Voltage | Single-phase 220V |
| Output Voltage | Three-phase 220V |
| Output Power | 750W (0.75KW) / 1500W (1.5KW) |
| Output Frequency | 1.0-99.0Hz |
| Weight | 0.5KG |
| Size (L*W*H) | 60.5mm * 102.5mm * 130mm (approx. 60*100*125 as per some specs) |
| Origin | Mainland China |
| Certification | CE |
9. User Tips
- Motor Compatibility: This VFD is designed for three-phase motors. Ensure your motor is compatible with a 220V three-phase supply. For example, a 1 HP motor (approx. 750W) should work well with the 750W variant.
- Panel vs. Remote Control: The VFD can be operated directly from the control panel using the RUN/STOP keys and potentiometer. For remote control or advanced configurations, refer to the parameter settings for switching between digital and remote modes, and utilize the external sensor inputs or 485 communication interface as needed.
- Parameter Configuration: Take time to understand the parameter settings (Pxxx) to optimize the VFD's performance for your specific application, such as adjusting acceleration/deceleration times to prevent overcurrent faults.
10. Warranty and Support
The SUSWE 820 VFD comes with a 1-year warranty from the date of purchase, covering manufacturing defects. For technical support, troubleshooting assistance, or warranty claims, please contact your seller or the manufacturer directly. Remote package debugging guidance may also be available.