GOLDEN GH-1A Series (T73A)

Contents

GH-1A Series Relay Instruction Manual

Models: GH-1A-5L, GH-1A-9L, GH-1A-12L, GH-1A-12LF, GH-1A-24L, GH-1A-12H (T73A)

1. Introduction

The GOLDEN GH-1A series relays are compact, 4-pin electrical components designed for various switching applications in electronic circuits. This manual provides essential information for the safe and effective use of your relay, covering specifications, installation, operation, and maintenance.

2. Specifications

The GH-1A series includes several models, each with specific coil voltages and contact ratings. All models are 4-pin relays.

2.1 General Specifications

  • Certification: CE
  • Origin: Mainland China
  • EU LVD Voltage: Below 50Vac or 75Vdc
  • High-concerned chemical: None

2.2 Model-Specific Electrical Ratings

Model Coil Voltage Contact Rating (AC) Contact Rating (DC) Notes
GH-1A-5L 5VDC 12A 250VAC, 10A 277VAC, 15A 125VAC, TV-5 120VAC 15A 16VDC, 15A 28VDC
GH-1A-9L 9VDC 6A 250VAC, 7.5A 250VAC, 15A 125VAC 15A 16VDC, 15A 28VDC
GH-1A-12L 12VDC 12A 250VAC, 10A 277VAC, 15A 125VAC, TV-5 120VAC
GH-1A-12LF 12VDC 10A 250VAC, 10A 277VAC, 15A 125VAC, 7A 250V
GH-1A-24L 24VDC 12A 250VAC, 10A 277VAC, 15A 125VAC, TV-5 120VAC
GH-1A-12H 12VDC 10A 250VAC, 15A 125VAC, 10A 277VAC Approx. 180 Ohm coil resistance

2.3 Physical Dimensions (T73A Type)

  • Length: 19 mm
  • Width: 15.2 mm
  • Height: 15.5 mm
  • Pin Diameter: 1.3 mm
T73A Relay Dimensions and Wiring Diagram
Figure 1: T73A Relay Dimensions and Wiring Diagram. This diagram shows the physical measurements (length, width, height, pin spacing) and the internal schematic of the relay, including the coil and the normally open (NO) contact.

2.4 Product Images for Identification

GH-1A-12L Relay
GH-1A-12L Relay (12VDC Coil, 12A)
GH-1A-12LF Relay
GH-1A-12LF Relay (12VDC Coil, 10A)
GH-1A-5L Relay
GH-1A-5L Relay (5VDC Coil, 12A)
GH-1A-24L Relay
GH-1A-24L Relay (24VDC Coil, 12A)
GH-1A-9L Relay
GH-1A-9L Relay (9VDC Coil, 6A/7.5A/15A)
GH-1A-12H Relay
GH-1A-12H Relay (12VDC Coil, 10A/15A)

3. Setup

Relays are electromechanical switches that require careful installation to ensure proper function and safety. Always ensure power is disconnected before handling electrical components.

  1. Identify Pins: Refer to the wiring diagram (Figure 1) to identify the coil pins and the contact pins (Common, Normally Open (NO), Normally Closed (NC) if applicable). The GH-1A series typically features a single pole, normally open (SPST-NO) configuration, meaning it has two coil pins and two contact pins (one common, one NO).
  2. Match Voltage: Ensure the control voltage supplied to the relay coil matches the specified coil voltage of your specific GH-1A model (e.g., 5VDC for GH-1A-5L, 12VDC for GH-1A-12L). Applying incorrect voltage can damage the relay.
  3. Connect Coil: Connect your control circuit's power supply to the two coil pins. Polarity may be important for some DC relays, though many small DC relays are non-polarized.
  4. Connect Load: Connect the load circuit (the device you want to switch) to the contact pins. Ensure the current and voltage of your load do not exceed the relay's contact ratings. For a Normally Open (NO) configuration, connect one side of your load to the common pin and the other side to the NO pin.
  5. Secure Installation: Mount the relay securely in your circuit board or enclosure to prevent accidental disconnections or damage.

Safety Warning: Incorrect wiring can lead to electrical hazards, component damage, or fire. If you are unsure, consult a qualified electrician or electronics technician.

4. Operating

Once properly installed, the GH-1A series relay operates as follows:

  1. Coil Activation: When the specified coil voltage is applied across the coil pins, an electromagnetic field is generated.
  2. Contact Switching: This electromagnetic field attracts an armature, causing the internal contacts to switch. For a Normally Open (NO) relay, the contacts will close, completing the load circuit.
  3. Deactivation: When the coil voltage is removed, the electromagnetic field collapses, and a spring returns the contacts to their original (normally open) state, breaking the load circuit.

Always ensure that the load current and voltage remain within the relay's specified contact ratings to prevent premature wear or failure.

5. Maintenance

The GH-1A series relays are designed for long-term, maintenance-free operation under normal conditions. However, periodic inspection can help ensure reliability:

  • Visual Inspection: Periodically check the relay for any signs of physical damage, discoloration (indicating overheating), or loose connections.
  • Environmental Conditions: Ensure the relay is operating within its specified environmental conditions (temperature, humidity) to prevent degradation.
  • Cleaning: Keep the area around the relay clean and free from dust or debris, which could potentially interfere with its operation or heat dissipation.

Do not attempt to open the relay housing, as this can damage the internal components and void any potential warranty.

6. Troubleshooting

If your GH-1A series relay is not functioning as expected, consider the following:

  • No Switching:
    • Verify that the correct coil voltage is being applied to the coil pins.
    • Check for continuity across the coil pins to ensure the coil is not open-circuited.
    • Ensure all connections to the relay are secure and properly soldered.
  • Load Not Activating:
    • Confirm that the relay coil is activating (you might hear a faint click or measure continuity across the contacts when the coil is energized).
    • Check the load circuit for faults, such as open circuits or short circuits.
    • Ensure the load's current and voltage requirements do not exceed the relay's contact ratings, which could lead to contact welding or burning.
  • Intermittent Operation:
    • Inspect for loose connections or cold solder joints.
    • Check for voltage fluctuations in the coil supply.

7. User Tips

Based on user feedback, the GH-1A series relays are generally regarded for their good quality and accurate description. To ensure optimal performance and longevity:

  • Always double-check the coil voltage and contact ratings against your application requirements before installation.
  • Consider using a flyback diode across the coil of DC relays to protect control circuitry from voltage spikes when the coil de-energizes.

8. Warranty and Support

The GOLDEN GH-1A series relays are manufactured to high standards and are CE certified. For any technical assistance, questions, or support regarding your product, please contact the seller or manufacturer directly. Provide your product model and any relevant purchase information when seeking support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.