1. Introduction
This document provides detailed instructions for the installation, operation, and maintenance of the Easun Power 5600W Hybrid Solar Inverter, Model ISolar SMG II 5.6KW. This multi-function inverter/charger combines the capabilities of an inverter, an MPPT solar charger, and a battery charger to deliver reliable, uninterruptible power. Its user-friendly LCD display and accessible buttons allow for easy configuration of settings such as battery charging current, AC/solar charger priority, and acceptable input voltage, adapting to various application needs.
Key Features:
- Pure sine wave solar inverter
- Output power factor 1
- High PV input voltage range
- Built-in MPPT solar controller
- Battery equalization function to optimize battery performance and extend lifecycle
- Inverter can run without battery
- Built-in anti-dust kit for harsh environments
- WIFI-GPRS remote monitoring (Optional)
- Detachable LCD (Optional)
- Parallel function (requires external cables)

Figure 1: Easun Power 5600W Hybrid Solar Inverter highlighting 5.6KW, 48V, 100A Max Solar Charge Current, 5600W Rated Power, and 500VDC Max PV Array Voltage.
2. Setup and Installation
2.1 Product Overview

Figure 2: Various views of the inverter, showing front, side, and rear panels.
2.2 Connection Points
The rear panel of the inverter features several connection points for AC input, AC output, PV input, battery, and communication interfaces. Ensure all connections are secure and correctly polarized.

Figure 3: Detailed view of the inverter's rear panel connections.
- Parallel communication port: Used for parallel operation (only for parallel models).
- Current sharing cable: Used for parallel operation (only for parallel models).
- AC input: Connects to the utility grid or generator.
- AC output: Connects to household appliances/loads.
- PV input: Connects to solar panels.
- Grounding: Essential for safety.
- RS232 communication port: For data communication.
- USB communication port: For data communication.
- Input breaker: Circuit protection.
- Power on/off switch: Main power control.
- Dry contact: For external control or signaling.
- Battery input: Connects to battery bank (Positive and Negative terminals).
2.3 System Connection Diagram
The inverter supports various configurations, including connections to solar power, a generator, the utility grid, and battery packs to power various loads.

Figure 4: Comprehensive system diagram illustrating connections for solar power, generator, utility grid, battery packs, and household loads.
2.4 Battery Connection
The 5.6KW model supports a 48VDC battery system. Ensure correct polarity when connecting batteries.

Figure 5: Battery connection diagram for a 48VDC system, showing four 12V batteries in series.
2.5 PV Connection
When selecting PV modules, consider the following parameters:
- Open Circuit Voltage (Voc) of PV modules should not exceed the maximum PV array open circuit voltage of the inverter (500VDC).
- Open Circuit Voltage (Voc) of PV modules should be higher than the minimum battery voltage.

Figure 6: PV connection diagram showing solar panels connected to the inverter, which then powers the house and charges batteries.
2.6 WIFI Module Connection
The inverter includes a WIFI module for remote monitoring via a mobile phone application. Connect the provided WIFI module to the RS232 port on the inverter's rear panel. For detailed instructions on setting up the WIFI monitoring, please refer to the full user manual, typically found on page 40 or in the dedicated WIFI module guide.
Video 1: Product overview and demonstration of connecting the WIFI module to the inverter's RS232 port.
3. Operating Instructions
3.1 LCD Display and Function Keys
The inverter features a comprehensive LCD display and several function keys for user interaction and monitoring.

Figure 7: Front panel of the inverter showing the LCD display, LED indicators, and function keys.
| LED Indicator | Messages |
|---|---|
| AC / INV (Green, Solid On) | Output is powered by utility in Line mode. |
| AC / INV (Green, Flashing) | Output is powered by battery or PV in battery mode. |
| CHG (Green, Solid On) | Battery is fully charged. |
| CHG (Green, Flashing) | Battery is charging. |
| FAULT (Red, Solid On) | Fault occurs in the inverter. |
| FAULT (Red, Flashing) | Warning condition occurs in the inverter. |
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
3.2 LCD Display Information
The LCD provides real-time status and information about the inverter's operation.

Figure 8: Examples of LCD display states: 1. With battery, solar, and AC available; 2. With battery, solar, and AC not available; 3. Without battery, solar available; 4. Without battery, AC available.
| Icon | Function description |
|---|---|
| AC | Indicates the AC input. |
| PV | Indicates the PV input. |
| INPUTBATT/kW/Hz | Indicates input voltage, input frequency, PV voltage, battery voltage and charger current. |
| Configuration Program and Fault Information | |
| 88 | Indicates the setting programs. |
| 88 (Warning icon) | Indicates the warning and fault codes. Flashing with warning code. |
| 88 (Fault icon) | Lighting with fault code. |
| Output Information | |
| OUTPUTBATT/LOAD/kW/Hz | Indicates output voltage, output frequency, load percent, load in VA, load in Watt and discharging current. |
| Battery Information | |
| CHARGING | Indicates battery level by 0-24%, 25-49%, 50-74% and 75-100% in battery mode and charging status in line mode. In AC mode, it will present battery charging status. |
| Status | Battery voltage | LCD Display |
|---|---|---|
| Constant Current mode | < 2V/cell | 4 bars will flash in turns. |
| Constant Current mode | 2 ~ 2.083V/cell | Bottom bar will be on and the other three bars will flash in turns. |
| Constant Voltage mode | 2.083 ~ 2.167V/cell | Bottom two bars will be on and the other two bars will flash in turns. |
| Floating mode | > 2.167 V/cell | Bottom three bars will be on and the top bar will flash. |
| Batteries are fully charged. | 4 bars will be on. |
3.3 System Operation with Battery Connected

Figure 9: Diagram illustrating the flow of power when the inverter operates with a connected battery, integrating solar, grid, and generator inputs.
4. Maintenance
4.1 Anti-Dust Filter
The inverter is equipped with an anti-dust filter to protect internal components from dust accumulation, especially in harsh environments. Regularly inspect and clean the filter to ensure optimal airflow and prevent overheating. The filter contains a sponge that can be removed for cleaning.
4.2 General Maintenance Tips
- Keep the inverter in a well-ventilated area, free from obstructions to airflow.
- Periodically check all cable connections for tightness and signs of wear or corrosion.
- Ensure the inverter is kept clean and dry. Avoid exposure to moisture or direct sunlight.
- For any internal maintenance or repairs, contact qualified service personnel.
5. Troubleshooting
If the inverter is not functioning as expected, check the LCD display for any warning or fault codes. Refer to the LCD Display Information table in Section 3.2 for code interpretations. Common issues can often be resolved by checking connections, ensuring proper ventilation, or verifying battery and PV input voltages.
For detailed troubleshooting steps and specific error code resolutions, please consult the comprehensive troubleshooting section in the full user manual provided with your product.
6. Specifications
Below are the technical specifications for the ISolar SMG II 5.6KW model:
| Category | Specification |
|---|---|
| Model | ISolar SMG II 5.6KW |
| Capacity | 5.6KVA/5.6KW |
| Parallel Capability | NO (Requires external cables for parallel function) |
| INPUT | |
| Nominal Voltage | 230VAC |
| Acceptable Voltage Range | 170-280VAC (For Personal Computer); 90-280VAC (For Home Appliances) |
| Frequency | 50/60Hz (Auto sensing) |
| OUTPUT | |
| Nominal Voltage | 220/230VAC±5% |
| Surge Power | 11000VA |
| Frequency | 50/60Hz |
| Waveform | Pure Sine wave |
| Transfer Time | 10Ms (For Personal Computer); 20Ms (For Home Appliances) |
| Peak Efficiency (PV to INV) | 96% |
| Peak Efficiency (Battery to INV) | 93% |
| Overload Protection | 5s@>=150%load; 10s@110%-150%load |
| Crest Factor | 3:1 |
| Admissible Power Factor | 0.6-1 (inductive or capacitive) |
| BATTERY | |
| Battery Voltage | 48VDC |
| Floating Charge Voltage | 54VDC |
| Over Charge Protection | 63VDC |
| Charging Method | CC/CV |
| SOLAR CHARGER & AC CHARGER | |
| Solar Charger Type | MPPT |
| Max. PV Array Power | 5500W |
| Max. PV Array Open Circuit Voltage | 500VDC |
| PV Array MPPT Voltage Range | 120VDC-450VDC |
| Max. Solar Input Current | 18A |
| Max. Solar Charge Current | 100A |
| Max. AC Charge Current | 60A |
| Max. Charge Current | 100A |
| PHYSICAL | |
| Dimensions (DxWxH) | 482x290x113mm |
| Package Dimensions (DxWxH) | 565x380x190mm |
| Net Weight | 10 Kgs |
| Communication Interface | USB/RS232/Dry-contact |
| ENVIRONMENT | |
| Operating Temperature Range | -10℃ to 50℃ |
| Storage Temperature | -15℃ to 60℃ |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) |

Figure 10: Full technical specifications for the ISolar SMG II series, including the 5.6KW model.
7. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your original point of purchase or the manufacturer directly. Ensure you have your product model number (ISolar SMG II 5.6KW) and serial number readily available when seeking support.
8. User Tips
- When connecting the WIFI module, ensure it is securely plugged into the RS232 port for reliable remote monitoring.
- Always double-check battery polarity before making connections to prevent damage to the inverter and batteries.
- For parallel operation, ensure you use the specified communication cables and follow the detailed instructions in the full user manual to avoid synchronization issues.
- Regularly monitor the LCD display for any warning or fault indicators to address potential issues promptly.