Bosean FS-600

Contents

Bosean FS-600 Nuclear Radiation Detector User Manual

Model: FS-600 | Brand: Bosean

1. Introduction

The Bosean FS-600 is a portable nuclear radiation detector designed to accurately measure X-ray, Beta, and Gamma radiation. It features a built-in Geiger counter for precise measurements and a wide detection range. This manual provides essential information for the safe and effective use of your FS-600 radiation detector.

Key features include real-time dose rate measurement, cumulative dose recording, adjustable alarm thresholds, and various display and sound options.

Bosean FS-600 Radiation Detector showing 0.15 µSv/h

Figure 1: Bosean FS-600 Radiation Detector

2. Package Contents

Upon unpacking, please verify that all items listed below are present and in good condition:

  • Bosean FS-600 Radiation Detector
  • 3 x AAA Batteries
  • USB Cable (for power supply)
  • Small Screwdriver
  • Operation Manual
  • After-sales Service Warranty Card
Contents of the Bosean FS-600 package including the detector, batteries, USB cable, screwdriver, and manual.

Figure 2: Package Contents

3. Specifications

FeatureSpecification (FS-600)
MaterialABS
Detectable SpeciesBeta, Gamma, X-ray
Sensor TypeG-M tube (Geiger-Müller tube)
Energy Range50keV - 1.5MeV (less than 30%)
Relative Intrinsic Error< ±10%
Sensitivity80cpm / µSv / Co-60
Measuring Range0.1µSv/h - 10mSv/h
Max Dose Equivalent Rate10mSv/h
Voice SourceReal particle sound / Alarm sound / Mute
Alarm Threshold0.5 (Adjustable)
Operating Temperature-25°C to +45°C
Relative Humidity< 95%
Power Supply3 x AAA batteries or USB cable
Item Weight145g / 5.1oz
Dimensions116 x 60 x 25mm
History DataYes
Connect with ComputerNo (Only FS-1000 and FS-5000 models)
Colorful ScreenNo

Table 1: FS-600 Specifications

Comparison table for FS-600, FS-1000, and FS-5000 Geiger counters, detailing features like sensor type, ray types, cumulative dose, power supply, and PC connectivity.

Figure 3: Model Comparison Chart

4. Setup

4.1 Power Supply

The FS-600 can be powered by three AAA batteries or via the included USB cable.

  • Battery Installation:
    1. Using the provided screwdriver, open the battery compartment cover on the back of the device.
    2. Insert three AAA batteries, ensuring correct polarity (+/-).
    3. Close the battery compartment cover and secure it with the screw.
  • USB Power: Connect the included USB cable to the Type-C port on the side of the device and to a standard USB power source (e.g., computer, USB wall adapter).
Image showing the two power supply modes for the radiation detector: USB power supply and 3 AAA batteries.

Figure 4: Two Power Supply Modes

Watch this video for a visual guide on battery installation and basic operation:

Video 1: FS-600 Battery Installation and Basic Operation

5. Operation

5.1 Power On/Off

Press and hold the "OK/U" button to power the device on or off.

5.2 Main Display Interface

The main display shows real-time radiation dose rate (R), cumulative dose (D), and other relevant information. The device can display measurements in µSv/h and µSv.

Measurement interface showing real-time, average, total dose, and GM particle count in different units.

Figure 5: Measurement Interface

5.3 Menu Navigation and Settings

Use the arrow buttons (up/down) to navigate through menu options and the "OK/U" button to select. The menu allows you to adjust various settings:

  • Alarm Rate: Set the threshold for the dose rate alarm.
  • Alarm Dose: Set the threshold for the cumulative dose alarm.
  • Clear Dose: Reset the cumulative dose value.
  • RateRatio: (Specific to certain models or advanced settings, typically related to conversion factors).
  • DateTime: Adjust the device's date and time.
  • Language: Select the display language.
  • Curve: View the real-time dose rate curve display.
  • Back Light: Turn the screen backlight ON or OFF.
  • Sound Light: Control particle sound and alarm sound settings.
FS-600 display showing menu options for settings like Alarm Rate, Alarm Dose, Clear Dose, DateTime, Language, Curve, Back Light, and Sound Light.

Figure 6: Menu Display

Setup interface showing options to set alarm preset value, time, and particle sound switch.

Figure 7: Setup Interface

5.4 Alarm Functions

The FS-600 features dual alarm functions for both dose rate and cumulative dose. When a set threshold is exceeded, the device will trigger an alarm (sound, particle sound, or light, depending on settings).

FS-600 showing 'Triple Alerts' modes: Sound, Particle, and Light.

Figure 8: Triple Alarm Modes

If the radiation dose rate exceeds 10mSv/h, the device will display "999MAX" as a blocking warning prompt.

5.5 Data Storage

The device has built-in memory to store the accumulated dose value, dose rate alarm threshold, and dose alarm threshold data, which will not be lost after power off.

Image indicating built-in data storage card, ensuring data is not lost after power failure.

Figure 9: Built-in Data Storage

6. Maintenance

  • Cleaning: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Battery Replacement: Replace AAA batteries when the low battery indicator appears on the screen. Ensure correct polarity.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures when not in use for extended periods.
  • Avoid Impact: Protect the device from drops and strong impacts, as this can damage the sensitive internal components, especially the Geiger-Müller tube.

7. Troubleshooting

  • Device does not power on:
    • Check if the AAA batteries are installed correctly and are not depleted.
    • Ensure the USB cable is properly connected and the power source is active if using USB power.
  • Inaccurate readings:
    • Ensure the device is used within the specified ambient temperature and humidity ranges.
    • Avoid strong electromagnetic interference sources nearby.
    • The device is designed to detect X, Beta, and Gamma rays. It will not detect other types of radiation or substances like natural gas.
  • "999MAX" displayed: This indicates that the radiation dose rate has exceeded 10mSv/h, which is a high level. Immediately move away from the source of radiation.
  • No particle sound/alarm: Check the "Sound Light" settings in the menu to ensure particle sound and alarm sound are enabled.

8. User Tips

  • Understanding Readings: Familiarize yourself with typical background radiation levels in your area to better interpret the device's readings.
  • Battery Life: While the device has a low battery reminder, carrying spare AAA batteries is recommended for continuous use, especially in critical situations.
  • Model Differences: Note that only FS-1000 and FS-5000 models can connect to a computer for data management. The FS-600 does not have this feature.
  • Calibration: For professional or highly sensitive applications, periodic calibration by certified laboratories is recommended to ensure accuracy.

9. Warranty and Support

Bosean is committed to providing high-quality products. This device comes with an After-sales Service Warranty Card. Please refer to the card for specific warranty terms and conditions.

Bosean products adhere to strict quality management systems and hold various certifications, including CE and FCC, ensuring reliability and safety.

Image showing the device connected to a PC terminal for data management. Note: This feature is for FS-1000 and FS-5000 models only, not FS-600.

Figure 10: PC Connectivity (Applicable to FS-1000/FS-5000 only)

Image showing various certifications and quality assurance logos including ISO9001, CNEX, CE, and FCC.

Figure 11: Quality Certifications


Ask a question about this manual