1. Introduction
This Bykski Granzon DDC Pump-Reservoir Combo is designed for high-performance PC thermal management, providing efficient water circulation for custom liquid cooling loops. It features a digital display for real-time monitoring and wireless speed control for convenient adjustments. The unit is compatible with standard G1/4" thread fittings and is available with various reservoir lengths to suit different build requirements.

2. Safety Information
IMPORTANT WARNING / SAFETY INFORMATION
- LEAKAGE RISK: Improper installation may cause coolant leakage, leading to permanent damage to electronic components. Always perform a pressure or leak test before full system power-on.
- ELECTRICAL SAFETY: Ensure all RGB/D-RGB cables are connected to the correct voltage headers (e.g., 5V vs 12V). Wrong connection may cause short circuits or fire.
- CHEMICAL SAFETY: Keep coolants out of reach of children. If ingested, seek medical attention immediately.
- CHOKING HAZARD: This product contains small parts (screws, fittings). Keep away from children under 3 years old.
- USAGE RESTRICTIONS: Do not mix aluminum and copper components in the same loop to avoid galvanic corrosion. Use only specialized PC coolants.
3. Specifications
| Feature | Description |
|---|---|
| Brand Name | bykski |
| Model Number | GFMB CT-F60-AL-V2 |
| Type | DDC Pump Kit |
| Material | Acrylic (Note: Black top cover material recently updated to POM from aluminum alloy) |
| RGB Support | NO RGB |
| Flow Rate | 700 L/H (approx.) |
| Lift | 6 meters (approx.) |
| Control | Digital Display, Wireless Speed Control |
| Pump Length | 84mm |
| Reservoir Lengths | 60mm, 100mm, 150mm, 200mm (various options) |
| Reservoir Diameter | 66mm |
| Origin | Mainland China |


4. Installation Guide
Follow these steps carefully to install your DDC Pump-Reservoir Combo:
- Inspection: Before installation, carefully inspect the product for any physical damage.
- Fittings Installation: Install the appropriate G1/4" thread fittings onto the pump and reservoir ports. Ensure all O-rings are securely in place to prevent leaks.
- Mounting: Secure the pump-reservoir combo to the designated PC chassis or a dedicated hardware mount. Refer to the provided diagrams for typical mounting positions within a PC case.
- Leak Test (Crucial): Before powering on the entire PC system, conduct a 24-hour leak test. Use a jump-start bridge to power only the pump, allowing it to circulate coolant and reveal any leaks without risking other components.
- Coolant Filling: Fill the reservoir with specialized PC coolant. Ensure the loop is properly bled of air.
- Electrical Connections: Connect the pump's power cable and any RGB/D-RGB cables to the correct voltage headers on your motherboard or controller. Refer to your motherboard manual for correct voltage (e.g., 5V vs 12V) to avoid damage.
5. Operation
The Granzon DDC Pump-Reservoir Combo features a digital display and wireless control for easy management.
- Digital Display: The integrated display provides real-time information such as pump RPM, flow rate, voltage, and load percentage. This allows for immediate monitoring of your cooling system's performance.
- Wireless Speed Control: Utilize the wireless control feature to adjust the pump speed as needed, optimizing between performance and noise levels.

6. Maintenance & Storage
- Loop Flushing: To prevent sediment buildup and maintain optimal performance, flush the entire liquid cooling loop every 6-12 months.
- Radiator Cleaning: It is recommended to use a professional radiator cleaning solution to clean radiators before use to avoid impurities entering the waterway.
- Storage: When not in use, store the pump-reservoir combo in a cool, dry place. Avoid direct sunlight on acrylic parts to prevent cracking and material degradation.
7. Troubleshooting
- Radiator Deformation: Radiators are pressure tested before leaving the factory, and fins are soft. In rare cases, transportation vibration may cause slight deformation. If fins are slightly skewed, it is a common phenomenon and does not affect performance. If the waterway is damaged or a leak is present, contact customer service immediately.
- Leakage: If a leak is detected during the leak test or operation, immediately power down the system. Re-check all fittings and O-rings for proper seating and tightness. Replace any damaged components.
- Pump Not Functioning: Verify all power connections are secure and correctly wired. Ensure the power supply is providing adequate voltage.
8. User Tips
- Modular Options: If you require a specific reservoir length without the pump, some models may be available for separate purchase. Check with the seller for availability of individual components.
- Material Update: Be aware that Bykski has recently changed the material of the black top cover from aluminum alloy to POM. This change is gradual, and the real object shall prevail without further notice.
9. Compliance & Certifications
This product complies with international safety and environmental standards:
- Compliance Mark: CE (Conformité Européenne) / RoHS
- Standards: Built in accordance with EU Directive 2011/65/EU and its amendment directives on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
10. Additional Resources
For a complete and detailed user manual, please refer to the official PDF document: