1. Introduction

The TENSTAR ROBOT AD620 Microvolt MV Voltage Amplifier is a high-precision signal instrumentation module designed to amplify microvolt (uV) and millivolt (mV) level voltages. Utilizing the AD620 as its core amplifier, this module offers adjustable magnification, high precision, low offset, and excellent linearity. It features an adjustable zero point to enhance accuracy and can be used for both AC and DC signal amplification applications.

Top view of the AD620 Microvolt MV Voltage Amplifier module with pin headers
Figure 1: Top view of the AD620 Amplifier Module with pin headers.

This module is compact, measuring 32 x 22mm, and includes four 3mm positioning holes for easy integration. It also provides 2.54mm standard pitch pinholes on both sides for connections. Users should possess a foundational understanding of electronics for proper and safe operation.

2. Setup and Connections

Before connecting the module, ensure your power supply and signal sources are within the specified ranges. Basic electronic knowledge is recommended for proper setup.

2.1 Pinout Diagram

Detailed pinout diagram of the AD620 module showing V-, GND, UIN, S-, S+, VOUT, GND labels
Figure 2: Detailed pinout and component layout of the AD620 Amplifier Module.

2.2 Connection Instructions

  1. Power Supply (UIN, GND): Connect a DC power source between 3V and 12V to the UIN (positive voltage input) and GND (ground) pins. Ensure correct polarity.
  2. Signal Input (S+, S-): Connect your microvolt or millivolt signal source to the S+ (non-inverting input) and S- (inverting input) pins.
  3. Signal Output (VOUT, GND): The amplified signal will be available at the VOUT pin, referenced to GND. The output range is approximately ±(Vin-2V).
  4. Negative Voltage Output (V-): The module provides a negative voltage output at the V- pin, generated by a 7660A chip. This can be used to drive other dual-power loads. Note that the actual output voltage at V- will be slightly higher than -Vin, and may drop further with increased load power due to internal resistance.

3. Operating Instructions

The AD620 module offers adjustable magnification and zero-point calibration to optimize performance for your specific application.

3.1 Magnification Adjustment

The module's magnification can be adjusted from 1.5 to 1000 times using the onboard potentiometer. Rotate the potentiometer (typically labeled "104" or "103" on the module, as seen in Figure 2) to achieve the desired gain for your input signal. Start with a lower gain and gradually increase it while monitoring the output to prevent saturation.

3.2 Zero Adjustment

To improve accuracy and eliminate zero drift, the module includes a zero adjustment potentiometer. With no input signal (S+ and S- shorted or connected to a stable zero reference), adjust the zero potentiometer until the output voltage (VOUT) is as close to 0V as possible. This calibration helps ensure that only the input signal is amplified, without an unwanted DC offset.

4. Maintenance

The AD620 amplifier module is designed for reliable operation with minimal maintenance. Follow these general guidelines:

  • Keep the module in a clean, dry environment to prevent dust and moisture accumulation.
  • Avoid exposing the module to extreme temperatures or humidity.
  • Handle the module with care to prevent physical damage to components or solder joints.
  • When making connections, ensure power is off to prevent short circuits or damage.

5. Troubleshooting

If you encounter issues with the AD620 amplifier module, consider the following troubleshooting steps:

  • No Output/Incorrect Output:
    • Verify that the input voltage (UIN) is within the 3-12VDC range and correctly polarized.
    • Check all signal and power connections for proper contact and absence of short circuits.
    • Ensure the input signal (S+, S-) is present and within the 100uV - 300mV range.
    • Adjust the magnification potentiometer. If set too low, the output may be imperceptible; if too high, the output may be saturated.
    • Perform the zero adjustment procedure to eliminate any DC offset.
  • Unstable Output:
    • Check for noise in the power supply or input signal.
    • Ensure proper grounding of the module and connected circuits.
    • Verify that the operating temperature is within acceptable limits.
  • Negative Voltage Output (V-) Issues:
    • If the negative voltage is lower than expected, reduce the load on the V- output. The output voltage is dependent on the load power.

If problems persist, consult with someone experienced in electronics or contact the seller for technical support.

6. Specifications

ParameterValue
Input Voltage3-12VDC
Magnification1.5-1000 times (adjustable)
Signal Input Voltage100uV - 300mV
Signal Output Range±(Vin-2V)
Negative Voltage OutputHigher than -Vin (load dependent)
Offset Voltage50μV
Input Bias Current1.0nA (max)
Common Mode Rejection Ratio (CMRR)100 dB
Offset Voltage Drift0.6μV / °C (maximum)
Stability2μV / month (maximum)
Dimensions32 x 22mm
Weight4g

7. User Tips

  • Start with Low Gain: When first setting up, it's advisable to start with the lowest magnification setting and gradually increase it. This helps prevent signal saturation and allows for finer tuning.
  • Calibrate Zero Regularly: For applications requiring high accuracy, periodically re-adjust the zero potentiometer, especially if the ambient temperature changes significantly.
  • Understand Negative Voltage Limitations: Be aware that the negative voltage output (V-) is load-dependent. For stable negative voltage requirements, an external dedicated negative voltage regulator might be necessary.
  • Consider Shielding: For very low-level microvolt signals, consider using shielded cables for inputs (S+, S-) to minimize external noise interference.

8. Warranty and Support

For specific warranty information and technical support regarding your TENSTAR ROBOT AD620 Microvolt MV Voltage Amplifier module, please refer to the documentation provided at the time of purchase or contact the seller directly. Ensure you retain your proof of purchase for any warranty claims.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.