1. Introduction
This manual provides essential information for the safe and effective use of the GOLDEN GN-1A series power relays. These compact, 4-pin relays are designed for various switching applications, offering reliable performance with different coil voltage options.
2. Safety Information
- Always disconnect power before installing or servicing the relay.
- Ensure the relay's voltage and current ratings match your application requirements.
- Installation should be performed by qualified personnel.
- Avoid exposing the relay to excessive moisture, dust, or extreme temperatures.
3. Product Overview
The GN-1A series relays are single-pole, double-throw (SPDT) devices, featuring a 4-pin configuration suitable for PCB mounting. They are available in different coil voltage versions:
- GN-1A-5L: 5V DC Coil
- GN-1A-12L: 12V DC Coil
- GN-1A-24L: 24V DC Coil
All models share common contact ratings of 16A at 277VAC, 16A at 30VDC, and 16A at 250V~.
4. Setup and Installation
The GN-1A series relays are designed for through-hole PCB mounting. Refer to the dimensional drawing and schematic for precise pin layout and mounting hole specifications.
- Prepare PCB: Ensure your Printed Circuit Board (PCB) has the correct hole pattern for the 4-pin relay.
- Insert Relay: Carefully insert the relay pins into the corresponding holes on the PCB.
- Solder Connections: Solder the pins securely to the PCB, ensuring good electrical contact and no short circuits.
- Connect Coil: Apply the rated DC voltage (5V, 12V, or 24V, depending on the model) to the coil pins. Observe polarity if indicated, though many relays are non-polarized for the coil.
- Connect Load: Connect the circuit to be switched to the contact pins. The relay features a Single Pole Double Throw (SPDT) configuration, meaning it has a Common (COM) pin, a Normally Open (NO) pin, and a Normally Closed (NC) pin.
4.1 Pin Configuration (Refer to Figure 5)
- The two pins on one side are for the coil.
- The two pins on the opposite side are for the contacts (Common and one switchable contact, typically NO/NC). The schematic shows a single switchable contact.
- Coil Pins: Apply the specified DC voltage to energize the coil.
- Contact Pins: These pins connect to the load circuit. When the coil is energized, the internal switch changes state.
5. Operating Instructions
The GN-1A relay operates by energizing its coil, which creates a magnetic field that moves a mechanical switch, thereby opening or closing electrical contacts. This allows a low-power control signal (to the coil) to switch a higher-power load circuit (through the contacts).
- Energizing the Coil: Apply the appropriate DC voltage (5V, 12V, or 24V) to the coil pins. You should hear a faint click as the contacts switch.
- De-energizing the Coil: Remove the voltage from the coil pins. The contacts will return to their default (Normally Closed) state.
- Load Connection: Connect your load to the contact terminals. Ensure the load's voltage and current do not exceed the relay's contact ratings (16A 277VAC, 16A 30VDC, 16A 250V~).
6. Maintenance
These relays are generally maintenance-free. However, to ensure longevity and reliable operation:
- Keep the relay and surrounding area clean and free from dust and debris.
- Avoid exposing the relay to corrosive gases or liquids.
- Operate within the specified temperature and humidity ranges.
- Regularly inspect the solder joints for any signs of fatigue or corrosion, especially in high-vibration environments.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Relay does not click when coil is energized. | Incorrect coil voltage, no power to coil, faulty coil, reversed polarity (if applicable). | Verify coil voltage and power supply. Check for continuity across coil pins. Ensure correct polarity. |
| Load does not switch ON/OFF. | Faulty contacts, incorrect wiring of load, load circuit issue. | Check continuity across contacts when coil is energized/de-energized. Verify load wiring and functionality. |
| Relay overheats. | Overcurrent through contacts, excessive coil voltage. | Ensure load current is within specifications. Verify coil voltage is correct. |
8. Specifications
| Feature | Specification |
|---|---|
| Model Variants | GN-1A-5L, GN-1A-12L, GN-1A-24L |
| Coil Voltage | 5V DC (GN-1A-5L), 12V DC (GN-1A-12L), 24V DC (GN-1A-24L) |
| Contact Configuration | SPDT (Single Pole Double Throw) |
| Contact Rating (AC) | 16A 277VAC, 16A 250V~ |
| Contact Rating (DC) | 16A 30VDC |
| Number of Pins | 4 |
| Mounting Type | Through-hole PCB Mount |
| Certification | CE |
| Dimensions (Approximate, L x W x H) | 17.78mm x 12.7mm x 10.5mm (excluding pins) |
9. User Tips
- Coil Protection: For DC coils, consider adding a flyback diode in parallel with the coil to protect driving circuitry from voltage spikes when the coil de-energizes.
- Load Type: While rated for 16A, consider derating the current for inductive loads or high-frequency switching to extend relay life.
- Environmental Factors: Ensure the operating environment is within the relay's specified temperature and humidity limits to prevent premature failure.
10. Warranty and Support
For warranty information or technical support, please contact the seller or manufacturer directly. Keep your purchase records for reference.