1. Overview
The INKBIRD ITC-306T is a pre-wired heating output temperature controller designed for precise temperature management in various applications such as breeding, planting, aquariums, and terrariums. It features a dual LCD display for simultaneous viewing of current and set temperatures, and offers a unique dual time cycle setting for day and night temperature control.
This plug-and-play device supports both Centigrade and Fahrenheit units, includes temperature calibration, and provides over-temperature and sensor fault alarms for enhanced safety and reliability. With a maximum output of 1200W (110V) or 2200W (220V), it is suitable for a wide range of heating equipment.

2. Safety Precautions
Please read and understand the following safety precautions before using the ITC-306T controller to prevent injury, electric shock, fire, or malfunction.
- Ensure the product is used within its specified operating parameters.
- Do not touch the terminals while power is supplied to avoid electric shock.
- Prevent metal pieces, wire clippings, or metallic shavings from entering the product, as this may cause electric shock, fire, or malfunction.
- Do not use the product in environments with flammable or explosive gases.
- Never disassemble, modify, or repair the product, nor touch any internal parts. This can lead to electric shock, fire, or malfunction.
- If output relays are used beyond their life expectancy, contact fusing or burning may occur. Always consider application conditions and use relays within their rated load and electrical life expectancy.
3. Product Components and Keys

3.1 Display and Indicators
- PV (Process Value): Displays the current measured temperature in running mode. In setting mode, it displays the menu code.
- SV (Setting Value): Displays the set temperature in running mode. In setting mode, it displays the setting value.
- Work 1 Indicator Lamp: Illuminates when heating is active.
- Work 2 Indicator Lamp: Not used for this model (heating only).
3.2 Control Keys
- SET Key: Press for 3 seconds to enter the menu for function settings. During setting, press for 3 seconds to quit and save changes.
- INCREASE Key (Up Arrow): Increases values in setting mode.
- DECREASE Key (Down Arrow): In running mode, press to inquire HD value. In setting mode, decreases values.
3.3 Output Sockets
- The Socket: Both sockets are for heating output and operate synchronously.

4. Setup and Key Operation
4.1 How to Set Parameters
- When the controller is operating normally, press the "SET" key for over 3 seconds to enter the parameter setup mode. The "SET" indicator light will turn on.
- The PV window will display the first menu code (e.g., "TS1"), while the SV window displays its corresponding setting value.
- Press the "SET" key to navigate to the next menu item.
- Use the "INCREASE" (Up Arrow) or "DECREASE" (Down Arrow) keys to adjust the current parameter value.
- After completing all settings, press the "SET" key for 3 seconds at any time to save the changes and return to normal temperature display mode.
- If no operation is performed for 10 seconds during setting, the system will automatically exit setting mode without saving changes.

4.2 Setup Flow Chart
For a visual representation of the parameter setup process, please refer to the detailed flowchart in the official PDF user manual. The steps outlined in section 4.1 provide the textual guide for parameter configuration.
4.3 Menu Instruction (TR=0, Default)
When the Time Setting function (TR) is set to 0 (Off), the following menu parameters are available:
| Menu Code | Function | Setting Range | Default Setting |
|---|---|---|---|
| TS1 | Temperature Set Value 1 | -50~99.9°C/-58~210°F | 25°C/77°F |
| DS1 | Heating Differential Value 1 | 0.3~15°C/1~30°F | 1.0°C/2°F |
| CA | Temperature Calibration | -15~15°C/-15~15°F | 0°C/0°F |
| CF | Display in Fahrenheit or Centigrade | C/F | C |
| TR | Time Setting | 0:Off; 1: On | 0 |
4.4 Menu Instruction (TR=1, Time Setting Function On)
When the Time Setting function (TR) is set to 1 (On), the controller operates with dual time cycle settings. Time A to Time B is one cycle (24 hours). During Time A to Time B, the controller uses TS1 and DS1 settings. During Time B to Time A, the controller uses TS2 and DS2 settings.
| Menu Code | Function | Setting Range | Default Setting |
|---|---|---|---|
| TS1 | Temperature Set Value 1 | -50~99.9°C/-58~210°F | 25°C/77°F |
| DS1 | Heating Differential Value 1 | 0.3~15°C/1~30°F | 1.0°C/2°F |
| CA | Temperature Calibration | -15~15°C/-15~15°F | 0°C/0°F |
| CF | Display in Fahrenheit or Centigrade | C/F | C |
| TR | Time Setting | 0:Off; 1: On | 1 |
| TS2 | Temperature Set Value 2 | 0~99.9°C/32~210°F | 25°C/68°F |
| DS2 | Heating Differential Value 2 | 0.3~15°C/1~30°F | 1.0°C/2°F |
| TAH | Time A setting Hour | 0~23 hours | 8(8:00) |
| TAM | Time A setting Minute | 0~59 minutes | 00(8:00) |
| TBH | Time B setting Hour | 0~23 hours | 18(18:00) |
| TBM | Time B setting Minute | 0~59 minutes | 00(18:00) |
| CTH | Current Hour Setting | 0~23 hours | 8 |
| CTM | Current Minute Setting | 0~59 minutes | 30 |
5. Operating Instructions
5.1 Basic Operation
- Power On: Plug the controller into a suitable power outlet. The display will light up, showing the current temperature (PV) and the set temperature (SV).
- Power Off: Unplug the controller from the power outlet.
- Display Modes: In normal running mode, the PV window shows the measured temperature, and the SV window shows the set temperature.
5.2 Temperature Control Range Setting (TS, DS)
The controller maintains the temperature within a specified range. When the measured temperature (PV) falls below or equals the set temperature (TS) minus the heating differential (DS), the system activates heating (WORK1 indicator ON). Heating stops when PV reaches or exceeds TS.
Example: If TS = 25°C and DS = 3°C, heating starts when PV ≤ 22°C (25-3) and stops when PV ≥ 25°C.
5.3 Cycle Time Setting (TR, TAH, TAM, TBH, TBM, CTH, CTM)
This function allows for different temperature settings during day and night cycles. Set TR=1 to enable this feature.
- TR (Time Setting): 0 for Off, 1 for On.
- TAH/TAM (Time A Hour/Minute): Sets the start time for the first temperature period (Time A).
- TBH/TBM (Time B Hour/Minute): Sets the start time for the second temperature period (Time B).
- CTH/CTM (Current Hour/Minute): Used to set the current time for the controller.
During Time A to Time B, the controller uses TS1 and DS1 settings. During Time B to Time A, it uses TS2 and DS2 settings.
Example: If Time A is 8:30 and Time B is 18:00, then from 8:30 to 18:00, TS1/DS1 are active. From 18:00 to 8:30 the next day, TS2/DS2 are active.
5.4 Temperature Calibration (CA)
If there is a discrepancy between the measured temperature and the actual temperature, use the calibration function to adjust the reading. The corrected temperature equals the measured temperature plus the calibration value (CA). CA can be positive, zero, or negative.
5.5 Display Unit Selection (CF)
You can choose to display temperature in Celsius (°C) or Fahrenheit (°F). The default setting is Celsius.
- To change the unit, enter setting mode and adjust the CF parameter.
- Attention: Changing the CF value will reset all other settings to factory defaults.
6. Maintenance
- Cleaning: Regularly clean the temperature probe to ensure accurate readings. Use a soft cloth and mild detergent if necessary, then rinse thoroughly with clean water.
- Storage: When not in use, store the controller in a dry, cool place, away from direct sunlight and extreme temperatures.
- Inspection: Periodically check cables and connections for any signs of wear or damage. Replace if necessary.
7. Error Description
- Sensor Fault Alarm: If the temperature sensor experiences a short circuit or open loop, the controller will enter sensor fault mode, display "ER", and sound an alarm. Press any key to dismiss the alarm. The system will return to normal operation once the sensor fault is resolved.
- Over-temperature Alarm: If the measured temperature exceeds the measuring range (below -50°C/-58°F or above 99°C/210°F), the controller will enter over-temperature alarm mode, display "HL", and sound an alarm. Press any key to dismiss the alarm. The system will return to normal operation when the temperature is within the measuring range.
- TE Error: If TR=1 is set and power is interrupted, a "beep-beep" alarm will sound at 0.5Hz frequency. The PV window will display the current temperature, and the SV window will show "TE error". Press any key to stop the alarm. To resolve, enter the setting menu, navigate to CTH (Current Hour Setting), set the present time (CTH, CTM), and then exit to normal working status.
8. Troubleshooting Guide
| Issue | Possible Causes | Solutions |
|---|---|---|
| The probe reading is incorrect. |
|
|
| Heating output will not turn on. |
|
|
| Heating output will not turn off. |
|
|
9. Specifications
| Feature | Specification |
|---|---|
| Temperature Control Range | -50~99 °C / -58~210 °F |
| Temperature Resolution | 0.1 °C / 0.1°F |
| Temperature Accuracy | ±1°C (-50 ~ 70°C) / ±1°F (-58 ~ 160°F) |
| Temperature Control Mode | On/Off Control, Heating |
| Input Power (US Plug) | 110V-120V 60Hz |
| Input Power (EU/AU Plug) | 220V-240V 50Hz |
| Temperature Control Output | Max. 10A, 100V~240V AC |
| Sensor Type | TPE plastic sensor (Included) |
| Sensor Length | 2m / 6.56ft |
| Relay Contact Capacity | Heating (10A, 100-240VAC) |
| Input Power Cable Length | 1.5m (5ft) |
| Output Power Cable Length | 25cm (1ft) |
| Controller Dimensions (Main Body) | 140x68x33mm (5.5x2.7x1.3 inch) |
| Ambient Temperature | -30~75 °C / -22~167°F |
| Storage Temperature | -20~60 °C / -4~140°F |
| Storage Humidity | 20~85% (No Condensate) |

10. Warranty and Support
The INKBIRD ITC-306T Aquarium Thermostat comes with a 1-year warranty for the digital thermostat and the aquarium probe.
For any usage issues, technical support, or warranty claims, please contact INKBIRD customer support:
- Email: support@inkbird.com
- Manufacturer: Shenzhen Inkbird Technology Co., Ltd.
- Address: Room 1803, Guowei Building, No.68 Guowei Road, Xianhu Community, Liantang, Luohu District, Shenzhen, China
You can also scan the QR code provided in the original manual or visit the official INKBIRD website for product usage videos and further support.
The full user manual is available in PDF format. For detailed instructions and diagrams, please refer to the official PDF manual: INKBIRD ITC-306T User Manual (PDF)
11. User Tips
- Probe Placement: Ensure the temperature probe is placed in an area with good water circulation (for aquariums) or air circulation (for other environments) to get accurate readings. Avoid placing it directly next to a heater or in a stagnant zone.
- Regular Calibration Check: Periodically verify the temperature reading against a known accurate thermometer. If there's a consistent deviation, use the calibration (CA) function to adjust for accuracy.
- Power Cycle for Reset: If you encounter unexpected behavior, a simple power cycle (unplugging and replugging) can often resolve minor glitches. For more persistent issues, refer to the troubleshooting section.
- Utilize Dual Time Cycle: For applications like breeding or planting, leverage the dual time cycle (TR=1) feature to mimic natural day/night temperature fluctuations, which can be beneficial for physiological needs.
12. Product Video
Watch this video for an unboxing and basic operation guide of the INKBIRD ITC-306T Temperature Controller.