1. Product Introduction
This device is an intelligent balancing protection board designed specifically for 6S-16S series lithium batteries, supporting ternary lithium/lithium iron phosphate batteries. Its main advantages include protecting the battery from overcharging, over-discharging, over-current, over-temperature, and short circuit. It provides balanced charging to achieve long-term maintenance of the battery through voltage balancing, thereby extending the service life of the battery pack. It is suitable for series-connected lithium battery packs. Once the individual cell voltage reaches the equilibrium turn-on voltage, the high voltage battery will be balanced until the equilibrium release voltage is reached.
2. Product Model Selection
| Parameter | Value |
|---|---|
| Number of strings | 6S-16S |
| Current | 30A/50A/80A |
| Applicable battery | NCM/LFP |
Note: The currently available models are listed in the table above. For other requirements, customization of 6-16S series is supported.
3. Product Model Description
To understand the model naming convention, consider a 50A protective board with 12 strings as an example:
- HT-616 LOS 12S 50A or HT-616 LPS 12S 50A
- 616: Indicates this series can support 6 to 16 strings.
- LOS: Denotes suitability for NCM (Nickel Cobalt Manganese) batteries.
- LPS: Denotes suitability for LFP (Lithium Iron Phosphate) batteries.
- 12S: Represents the number of strings for this BMS board.
- 50A: Specifies the discharge current of this BMS board.
4. Specifications
4.1. Lithium Iron Phosphate (LFP) Parameters
Test conditions: room temperature 25 °C. The over-current value and internal resistance of the protection board are dynamic parameters. The voltage of each battery cell needs to be ≥ 3.25 V during testing.
| Project | Symbol | Detailed Content | Standard |
|---|---|---|---|
| Serial number | S | Number of battery strings | 6-16S |
| Current | A | Current that the shield can withstand | 30/50/80A |
| Battery type | Lithium iron phosphate | Lithium iron phosphate | |
| Overcharge detection voltage | VDET1 | Overcharge detection voltage | 3.65V±0.035V |
| Overcharge detection delay time | tVDET1 | Overcharge detection delay time | 1.3s (MAX) |
| Overcharge relieve voltage | VREL1 | Overcharge relieve voltage | 3.55V±0.025V |
| Over discharge test voltage | VDET2 | Over discharge test voltage | 2.350V±0.025V |
| Delay time for over discharge detection | tVDET2 | Delay time for over discharge detection | 1.5s (MAX) |
| Over discharge relieve voltage | VREL2 | Over discharge relieve voltage | 2.55V±0.025V relieve |
| Discharge over-current detection voltage | VDET3 | Discharge over-current detection voltage | 100mV±25mV |
| Theoretical instantaneous single pulse current | IDP | @3.6V, 20-45°C MOSFET temp | 120A/200A/320A |
| Actual instantaneous multi-pulse current | IDP | 90A/150A/240A | |
| Duration | 1s | ||
| Protection release condition | Break short circuit | ||
| Short-circuit protection conditions | External load circuit short circuit | ||
| Short-circuit detection delay time | TSHORT | 300uS (MAX) | |
| Short-circuit protection release conditions | Break short circuit | ||
| Main circuit on state resistance | RDS | @3.4V battery voltage | B- to P-RDS≤0.3mΩ |
| Internal consumption | IDD | During operation | MIN: 0.3μΑ MAX: 100μΑ |
| Electricity balance detection voltage | VBU | 3.405V±0.035V | |
| Balance startup delay time | tVBU | 1.6S (MAX) | |
| Balance release voltage | VBL | 3.4V±0.035V | |
| 4.2V battery balance current | IB | 100mA±5mA | |
| Low temperature charging protection | -0 °C± 5 °C | No | |
| High temperature charging protection | 75 °C± 5 °C | Yes | |
| MAX continuous working current (Charge) | Rated current of charger | 30A/50A/80A (Equivalent to A of the protective board) | |
| MAX continuous working current (Discharge) | Rated current of battery pack | 30A/50A/80A (Equivalent to A of the protective board) | |
| Charger selection voltage | Number of strings × 3.65V ± 0.05V | 30A/50A/80A (Equivalent to A of the protective board) | |
| Charging MOS MAX withstand voltage | VDS | DC 85V |
4.2. Ternary Lithium (NCM) Parameters
Test conditions: room temperature 25°C. The over-current value and internal resistance of the protection board are dynamic parameters. The voltage of each battery cell needs to be ≥ 3.7 V during testing.
| Project | Symbol | Detailed Content | Standard |
|---|---|---|---|
| Serial number | S | Number of battery strings | 6S-16S |
| Current | A | Max continuous current | 30/50/80A |
| Battery type | Ternary lithium | Ternary lithium | |
| Overcharge detection voltage | VDET1 | Overcharge detection voltage | 4.25V±0.035V |
| Overcharge detection delay time | tVDET1 | Overcharge detection delay time | 1.3s (MAX) |
| Overcharge relieve voltage | VREL1 | Overcharge relieve voltage | 4.2V±0.025V |
| Over discharge test voltage | VDET2 | Over discharge test voltage | 2.8V±0.025V |
| Delay time for over discharge detection | tVDET2 | Delay time for over discharge detection | 1.5s (MAX) |
| Over discharge relieve voltage | VREL2 | Over discharge relieve voltage | 3.0V±0.025V relieve |
| Discharge over-current detection voltage | VDET3 | Discharge over-current detection voltage | 100mV±5mV |
| Theoretical instantaneous single pulse current | IDP | @3.6V, 20-45°C MOSFET temp | 120A/200A/320A |
| Actual instantaneous multi-pulse current | IDP | 90A/150A/240A | |
| Duration | 1s | ||
| Protection release condition | Break short circuit | ||
| Short-circuit protection conditions | External load circuit short circuit | ||
| Short-circuit detection delay time | TSHORT | 300uS (MAX) | |
| Short-circuit protection release conditions | Break short circuit | ||
| Main circuit on state resistance | RDS | @3.4V battery voltage | B- to P-RDS≤0.3mΩ |
| Internal consumption | IDD | During operation | MIN: 0.3μΑ MAX: 100μΑ |
| Electricity balance detection voltage | VBU | 4.22V±0.035V | |
| Balance startup delay time | tVBU | 1.6S (MAX) | |
| Balance release voltage | VBL | 4.21V±0.035V | |
| 3.59V battery balance current | IB | 100mA±5mA | |
| Low temperature charging protection | -0 °C± 5 °C | No | |
| High temperature charging protection | 75 °C± 5 °C | Yes | |
| MAX continuous working current (Charge) | Rated current of charger | 30A/50A/80A (Equivalent to A of the protective board) | |
| MAX continuous working current (Discharge) | Rated current of battery pack | 30A/50A/80A (Equivalent to A of the protective board) | |
| Charger selection voltage | Number of strings × 3.65V ± 0.05V | 30A/50A/80A (Equivalent to A of the protective board) | |
| Charging MOS MAX withstand voltage | VDS | DC 100V |
4.3. Specific Configuration Parameters
The following parameters apply to specific configurations of the HT-616L Series BMS:
11S, 12S, 13S, 14S (30A, 3.7V, Same Port)
- Size: 72*55*8mm
- Overcharge protection: 4.25V ± 0.25V
- Charging recovery: 4.2V
- Over-discharge protection: 2.8V ± 0.25V
- Discharge recovery: 3.0V
- Maximum continuous current: 30A
- Peak Current: 66A
- Balance current: 80 mA
- Balanced starting voltage: 4.15V ± 0.25V
- Self-consumption: ≤35uA
- Application: Applicable to 48V Electric bicycle and electric tools within 550W
6S, 7S (20A, 3.7V, Same Port)
- Size: 72*55*8mm
- Overcharge protection: 4.25V ± 0.25V
- Charging recovery: 4.2V
- Over-discharge protection: 2.8V ± 0.25V
- Discharge recovery: 3.0V
- Maximum continuous current: 30A
- Peak Current: 100A
- Balance current: 80 mA
- Balanced starting voltage: 4.15V ± 0.25V
- Self-consumption: ≤35uA
- Application: Applicable to 48V Electric bicycle and electric tools within 550W
8S (30A, 3.2V, Same Port)
- Size: 72*55*8mm
- Overcharge protection: 3.75V ± 0.25V
- Charging recovery: 3.55V
- Over-discharge protection: 2.2V ± 0.25V
- Discharge recovery: 2.7V
- Maximum continuous current: 30A
- Peak Current: 100A
- Balance current: 80 mA
- Balanced starting voltage: 3.515V ± 0.25V
- Self-consumption: ≤35uA
- Application: Applicable to 48V Electric bicycle and electric tools within 550W
5. Size and Dimensions
The length and width of the 6-16S series protection board are consistent, with thickness varying based on the current rating.

Figure: Heltec BMS board showing approximate dimensions (55mm width, 70mm height).
| Current | 30A | 50/80A |
|---|---|---|
| Thickness (MM) | 8 | 12 |
6. Setup: Wiring Diagram
Correct wiring is crucial for the safe and proper operation of the Battery Management System. Please follow the diagrams carefully for your specific battery configuration. Ensure all connections are secure before operation.

Figure: Wiring Diagram for 6S Battery Management System. This diagram illustrates the connections for a 6-cell series battery pack to the BMS, including battery positive (Pack+), battery negative (Pack-), charge negative (Charge-), and the balance leads (B- to B6).

Figure: Wiring Diagram for 7S Battery Management System. This diagram shows the connections for a 7-cell series battery pack to the BMS, including battery positive (Pack+), battery negative (Pack-), charge negative (Charge-), and the balance leads (B- to B7).

Figure: Wiring Diagram for 8S Battery Management System. This diagram details the connections for an 8-cell series battery pack to the BMS, including battery positive (Pack+), battery negative (Pack-), charge negative (Charge-), and the balance leads (B- to B8).

Figure: Wiring Diagram for 10S Battery Management System. This diagram illustrates the connections for a 10-cell series battery pack to the BMS, including battery positive (Pack+), battery negative (Pack-), charge negative (Charge-), and the balance leads (B- to B10).
For 12S, 13S, 14S, and 16S configurations, the wiring principle is similar to the diagrams provided above. Connect the balance leads from B- (negative terminal of the first cell) up to the positive terminal of the last cell (B12, B13, B14, or B16 respectively). Ensure the main battery positive (Pack+) and negative (Pack-) terminals are connected, along with the charge negative (Charge-) and controller connections as indicated in the general wiring diagrams.

Figure: General connection diagram for the BMS, showing the main power connections and balance leads.

Figure: Detailed general connection diagram for the BMS, providing a clearer view of the wiring points.
7. Product Accessories
The Heltec HT-616L Series BMS typically includes the following accessories:
- BMS Board: The main Battery Management System unit.
- Collection Line (Balance Leads): Two sets of balance wires (e.g., for 6S/7S/8S/10S configurations, one set of wires is provided). These wires are used to connect to each individual cell in the battery pack for voltage monitoring and balancing.

Figure: Heltec BMS board with its accompanying balance wires.
8. Operating Principles
The Heltec HT-616L Series BMS is designed to manage and protect lithium battery packs, ensuring their longevity and safe operation. Its core functions include:
- Overcharge Protection: Prevents individual battery cells from being charged beyond their safe voltage limit, which can lead to damage or thermal runaway.
- Over-discharge Protection: Stops discharging when cells reach their minimum safe voltage, preventing irreversible damage and capacity loss.
- Over-current Protection: Limits the current drawn from the battery to prevent damage to the cells and the BMS itself.
- Short Circuit Protection: Immediately cuts off power in the event of a short circuit to prevent severe damage and fire hazards.
- Over-temperature Protection: Monitors the battery temperature and takes action (e.g., reducing current or shutting down) if it exceeds safe operating limits.
- Balanced Charging: Actively balances the voltage of individual cells within the pack during charging. When a cell reaches the equilibrium turn-on voltage, the BMS will balance it until the equilibrium release voltage is reached, ensuring all cells are charged uniformly.
9. Maintenance
To ensure the optimal performance and longevity of your Heltec HT-616L Series BMS and battery pack, consider the following maintenance guidelines:
- Regular Inspection: Periodically check all wiring connections for looseness or damage. Ensure the BMS board is securely mounted and free from physical stress.
- Environmental Conditions: Operate the BMS within its specified temperature range. Avoid exposure to extreme heat, cold, moisture, or corrosive environments.
- Battery Health: Monitor the overall health of your battery pack. While the BMS provides protection, severely degraded cells can still impact performance.
- Software Updates: If applicable, check the manufacturer's website for any firmware or software updates for your BMS model.
- Cleaning: Keep the BMS board clean and free of dust and debris. Use a soft, dry brush or compressed air for cleaning.
10. Troubleshooting and Fault Handling
This section outlines common fault phenomena, their potential causes, and recommended processing methods.
| Fault Phenomenon | Fault Inspection and Cause | Processing Method |
|---|---|---|
| Can't discharge | First, connect the circuit to activate the protection board for charging, and then measure the voltage of each battery separately. If the voltage of any battery is lower than 3.0V±0.025V (NCM) / 2.35V±0.025V (LFP), the protection board will start over-discharge protection. | If the battery is lower than 3.0V, please charge the battery to 3.7V (NCM) / 3.25V (LFP) and balance it before combining. Do not mix good batteries with poor batteries. If you cannot solve this problem, please contact after-sales service. |
| Can't charge | Measure the voltage of each battery section. If any battery voltage is higher than 4.215V (NCM) / 3.615V (LFP), the protection board will start overcharge protection. | If the battery is higher than 4.215V (NCM) / 3.615V (LFP), please discharge the battery to about 3.7V until it is balanced before combining. Do not mix good batteries with poor batteries (if you cannot solve this problem, please contact after-sales). |
| Charging/discharge failure | B-, B1, B2, B3, ......B+ Wrong wiring | Redraw the wiring or operate under the guidance of customer service. |
| Overcharge/discharge protection is invalid | B-, B1, B2, B3, ......B+ Wrong wiring | Redraw the wiring or operate under the guidance of customer service. |
| Discharge protection | Check whether the current value of the load starting power supply exceeds the over-current protection current of the protection board. | Replace the protection board with a larger current (if not solved, please contact after-sales). |
| Component is welded loosely | One of the components has a pin that is not connected to the PCB pad. | You can repair the welding by yourself (if it still cannot be solved, please contact after-sales). |
| Component welding | There is a short circuit between two or more pins of the element. | Remove the component and re-weld (if not, please contact after-sales). |
| Electrostatic breakdown | When the MOS tube is not powered, the forward and reverse resistance of any two pins of the G, D and S terminals are 0. | You can remove and replace the MOS tube by yourself (if it still cannot be solved, please contact after-sales). |
11. User Tips
No specific user tips were available from provided reviews or Q&A content.
12. Quality Assurance and Manufacturing
Heltec is committed to producing stable Battery Management System products. The manufacturing process involves automated assembly and rigorous testing to ensure product quality.
Video: Overview of the Heltec BMS manufacturing process, showcasing automated assembly lines and manual quality checks.

Figure: Close-up view of BMS components, highlighting the quality of assembly.

Figure: Another detailed view of BMS components, emphasizing precision manufacturing.

Figure: A further detailed view of BMS components, showcasing the robust design.
13. Warranty and Support
Warranty Regulations
The warranty service period for this product is 1 year. The warranty service is limited to normal use and does not cover man-made damage, self-disassembly, modification and repair, use not in accordance with the instructions, or damage caused by external force majeure factors. Accessories such as test fixtures are considered consumables and are not covered by warranty.
For warranty service, please contact your dealer for processing. If you cannot contact the dealer, you can contact our company by email or phone. Please note that there are no after-sales service stations in other countries except China. If you require warranty service and are outside China, you will need to send the product to us for free repair, but you will be responsible for the freight for the round trip.
Our company guarantees that each product is shipped after being tested by professional protection board testing instruments. Due to the nature of electronic components, the combination battery of the protection board may be damaged by static electricity and current, and it is normal to have defective products in use.
For a comprehensive guide and additional documentation, please refer to the official user manual PDF: Heltec HT-616L Series User Manual (PDF).