KKMOON AT8100

Contents

SMART SENSOR AT8100 Digital Oxygen Detector

User Manual

1. Introduction

The SMART SENSOR AT8100 is an intelligent and precise portable oxygen (O2) gas detector designed for various applications. Utilizing an electrochemical gas sensor, it provides quick response and high accuracy in measuring oxygen content. This device features a sound and light alarm system with adjustable thresholds, a clear backlit LCD display for easy reading, and a convenient USB rechargeable battery. It is an essential tool for effective prevention of hypoxia and oxygen poisoning in environments such as homes, agriculture, chemical industries, power plants, mines, tunnels, and underground pipelines.

SMART SENSOR AT8100 Digital Oxygen Detector in a kitchen setting, highlighting its features: Smart Chip, Instant Response, High Precision, Stable Performance, Sound + LED Alarm, Low Power Consumption.

Figure 1: SMART SENSOR AT8100 Digital Oxygen Detector with key features.

2. Product Overview

2.1 Components and Controls

Familiarize yourself with the main components and controls of your AT8100 Oxygen Detector:

Labeled diagram of the AT8100 Oxygen Detector showing Sensor, LCD Display, ON/OFF Switch, Up/Sound Button, Mode Button, Unit Button, °F/°C Switching, Down/Backlight Button, Charging Indicator, Alarm Indicator, and Buzzer.

Figure 2: Labeled diagram of the AT8100 Oxygen Detector.

  • Sensor: Located at the top, detects oxygen levels.
  • LCD Display: Large screen with backlight for clear readings.
  • ON/OFF Switch: Power button.
  • Up/Sound Button: Used for navigation and sound control.
  • Mode Button: Cycles through different operating modes.
  • Unit Button: Switches between measurement units (e.g., °F/°C).
  • Down/Backlight Button: Used for navigation and controlling the display backlight.
  • Charging Indicator: LED light indicating charging status.
  • Alarm Indicator: LED light for visual alarm.
  • Buzzer: Emits audible alarm.
  • USB Charging Port: Micro USB port for recharging the device.
Close-up images showing the sensitive probe, large LCD display, USB charging port, and simple operation buttons of the AT8100 Oxygen Detector.

Figure 3: Detailed views of key features.

2.2 Package Contents

Upon opening the package, ensure all items are present:

  • 1 x SMART SENSOR AT8100 Digital Oxygen Detector
  • 1 x USB Charging Cable
  • 1 x User Manual (this document)
  • 1 x Carry Bag
Contents of the AT8100 Oxygen Detector package, including the device, USB cable, user manual, and a black carry bag.

Figure 4: Package contents.

3. Specifications

Parameter Value
Model Number AT8100
Detecting Gas Oxygen (O2)
Measuring Range 0 ~ 25%
Resolution 0.1%
Basic Error ≤ ±5% full scale
Operating Temperature -10 ~ 50℃
Temperature Resolution 0.1℃
Working Humidity 1%RH ~ 99%RH
Response Time ≤15S
Recovery Time ≤15S
Alarm Mode Acoustic and Light
Auto Power Off Manual Selectable (10 mins no key press)
Power Supply 1 * 3.7V, 1000mAh rechargeable Li-ion battery
Screen Size 4.4 * 5.3cm / 1.73 * 2.08in
Item Size 180 * 65 * 30mm / 7.09 * 2.56 * 1.18in
Item Weight 182g / 6.42oz
Material ABS
Diagram showing the dimensions of the AT8100 Oxygen Detector: 180mm (7.09in) height, 65mm (2.56in) width, and screen size 44mm (1.73in) by 53mm (2.08in).

Figure 5: Product dimensions.

4. Setup

4.1 Initial Charging

Before first use, fully charge the device. Connect the supplied USB cable to the micro USB charging port on the detector and plug the other end into a compatible USB power source (e.g., power adapter, power bank, computer USB port). The Charging Indicator LED will illuminate during charging and typically change color or turn off when fully charged.

4.2 Power On/Off

  • To Power On: Press and hold the ON/OFF Switch (red button) until the LCD display illuminates.
  • To Power Off: Press and hold the ON/OFF Switch until the display turns off.

5. Operating Instructions

5.1 Basic Operation

  • Reading the Display: The large backlit LCD display shows the current oxygen concentration (O2 %) and temperature. The backlight ensures clear visibility even in dark conditions.
  • Mode Button: Use the MODE button to cycle through different display modes or settings if available.
  • Unit Button: Press the UNIT button to switch between temperature units (°F/°C).
  • Up/Sound Button: In settings, this button is used to increase values or navigate upwards. It may also control sound settings.
  • Down/Backlight Button: In settings, this button is used to decrease values or navigate downwards. A short press may toggle the backlight.

5.2 Setting Alarms

The AT8100 features an adjustable sound and light dual-alarm. When the oxygen concentration reaches the preset alarm level, the device will emit an acoustic sound and the Alarm Indicator LED will flash.

  • Refer to the detailed instructions in the full user manual (if available) for specific steps on how to customize the alarm thresholds. Generally, this involves entering a settings mode using the MODE button and adjusting values with the Up/Sound and Down/Backlight buttons.

5.3 Auto Power Off

The device has an auto power-off feature that can be manually selected. If no buttons are pressed for 10 minutes, the device will automatically power off to conserve battery. This feature can typically be enabled or disabled in the device settings.

5.4 Applications

The AT8100 Oxygen Detector is suitable for a wide range of environments where oxygen monitoring is crucial:

Hexagonal graphic illustrating various applications of the oxygen detector, including industrial facilities, laboratories, fire safety scenarios, tunnels, and large storage tanks.

Figure 6: Diverse applications of the AT8100 Oxygen Detector.

  • Metallurgy
  • Power Plants
  • Chemical Industries
  • Mines and Tunnels
  • Underground Pipelines
  • Laboratories
  • Agricultural Settings
  • General Industrial Environments
  • Home Safety

6. Maintenance

  • Cleaning: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the sensor area is kept clean and free from obstructions.
  • Storage: Store the detector in its provided carry bag in a cool, dry place away from direct sunlight and extreme temperatures when not in use.
  • Battery Care: Recharge the battery regularly, even if the device is not frequently used, to maintain battery health. Avoid fully discharging the battery for extended periods.
  • Sensor Longevity: The electrochemical sensor has a limited lifespan. If you notice inconsistent readings or frequent errors, the sensor may need replacement or recalibration. Contact customer support for assistance.

7. Troubleshooting

If you encounter issues with your AT8100 Oxygen Detector, consider the following:

  • Device not powering on: Ensure the battery is charged. Connect the device to a power source using the USB cable and try again.
  • Inaccurate readings: Ensure the sensor is clean and unobstructed. Avoid using the device in environments with extreme humidity or temperature fluctuations outside the specified operating range.
  • Alarm not sounding: Check if the alarm volume is set appropriately. Ensure the alarm thresholds are configured correctly.
  • Display issues: If the display is dim, ensure the backlight is activated. If the display is blank or shows errors, try restarting the device.

For persistent issues or technical support, please contact the manufacturer or seller.

8. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the contact details provided by your retailer or the manufacturer, KKMOON. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.