1. Introduction
This manual provides detailed instructions for the safe and effective operation of your MESTEK Digital Multimeter. This device is a versatile tool designed for electrical measurements, featuring a large display, intelligent recognition, and various measurement functions. Please read this manual thoroughly before use and keep it for future reference.
2. Safety Information
WARNING: To avoid electric shock or personal injury, please read and understand all safety information before using this product.
- Always ensure the multimeter is in the correct function and range for the measurement.
- Do not exceed the maximum input values specified for each function.
- Inspect test leads for damage before each use. Do not use if insulation is damaged or bare metal is exposed.
- Do not use the multimeter if it appears damaged or if it is not operating properly.
- Be cautious when working with voltages above 30V AC RMS, 42V peak, or 60V DC. Such voltages pose a shock hazard.
- Keep fingers behind the finger guards on the test probes during measurements.
- Do not operate the multimeter in explosive gas, vapor, or dusty environments.
- Always disconnect the test leads from the circuit before changing functions.
- Replace batteries as soon as the low battery indicator appears to ensure accurate readings and prevent incorrect measurements.
3. Package Contents
Verify that all items are present in your package:
- MESTEK Digital Multimeter
- Test Leads (Red and Black)
- Temperature Probe
- User Manual
- Packing Box

Image: Package contents including the multimeter, test leads, temperature probe, user manual, and packing box.
4. Product Overview
4.1 Key Features
The MESTEK Digital Multimeter offers a range of advanced features for precise and safe electrical measurements:
- High Count Display: 9999 counts for enhanced measurement accuracy.
- True RMS: Accurate measurements for non-sinusoidal waveforms.
- Auto/Smart Range: Automatically selects the appropriate measurement range (DM97A/A+ features Auto Range, DM97S/S+ features Smart Measure).
- AC/DC Voltage & Current: Measures both alternating and direct current voltage and current.
- NCV (Non-Contact Voltage) Detection: Safely detects AC voltage without direct contact.
- Capacitance & Resistance: Measures capacitance and resistance values.
- Frequency Tester: Measures frequency (Hz).
- Temperature Measurement: Includes a temperature probe for measuring temperature.
- Diode & Continuity Test: Checks diodes and circuit continuity with a buzzer.
- Live Wire Detection: Identifies live and neutral wires.
- Data Retention (HOLD): Freezes the displayed measurement for easy reading.
- Flashlight & Backlight: Integrated flashlight and display backlight for use in low-light conditions.
- Intelligent Anti-Burn Protection: Automatic identification of the measured object and all-round anti-burn protection.
- Large 3.5-inch HD Digital Display: Clear and easy-to-read display with large font size.
4.2 Multimeter Components
Familiarize yourself with the main parts of your multimeter:

Image: Front view of the MESTEK Digital Multimeter, highlighting its display, function buttons, and input terminals.
- Display: Large digital screen showing measurement values, units, and indicators.
- Function Buttons:
- Power Button: Turns the device on/off.
- V~ / V= Button: Selects AC or DC Voltage measurement.
- mA~ / mA= Button: Selects AC or DC Current measurement.
- Ω / ⟛ / )) Button: Selects Resistance, Diode, or Continuity test.
- Hz / % Button: Selects Frequency or Duty Cycle measurement.
- °F / °C Button: Toggles between Fahrenheit and Celsius for temperature.
- HOLD Button: Freezes the current display reading.
- NCV Button: Activates Non-Contact Voltage detection.
- Live Button: Activates Live Wire detection.
- Flashlight Button: Turns the flashlight on/off.
- Backlight Button: Turns the display backlight on/off.
- Input Jacks:
- mA: Input for current measurements up to 600mA.
- COM: Common (negative) input for all measurements.
- INPUT: Positive input for voltage, resistance, capacitance, frequency, diode, and temperature measurements.
Video: A brief overview of the MESTEK Digital Multimeter's features and functions.
5. Setup
5.1 Battery Installation
The multimeter typically uses AAA batteries. To install or replace batteries:
- Ensure the multimeter is turned off and test leads are disconnected.
- Locate the battery compartment cover on the back of the device.
- Open the cover (usually by unscrewing or sliding).
- Insert new batteries, observing correct polarity (+ and -).
- Close the battery compartment cover securely.
5.2 Connecting Test Leads
Always connect the black test lead to the "COM" jack. Connect the red test lead to the appropriate input jack based on the measurement type:
- For Voltage, Resistance, Capacitance, Frequency, Diode, and Temperature: Connect the red lead to the "INPUT" jack.
- For Current (mA): Connect the red lead to the "mA" jack.

Image: Test leads correctly inserted into the multimeter's input jacks for measurement, illustrating the intelligent anti-burn feature.
6. Operating Instructions
The MESTEK multimeter features intelligent recognition for many functions, simplifying operation. For specific measurements, select the corresponding mode.
6.1 Power On/Off
Press the Power Button (usually marked with a circle and a vertical line) to turn the multimeter on or off. The device may have an automatic shut-down feature after 5 minutes of inactivity to save battery.
6.2 AC/DC Voltage Measurement
- Connect the black test lead to the COM jack and the red test lead to the INPUT jack.
- Press the V~ / V= Button to select AC or DC voltage mode.
- Connect the test probes in parallel across the component or circuit to be measured.
- Read the voltage value on the display.

Image: Example of DC Voltage measurement displayed on the multimeter.

Image: Example of AC Voltage measurement displayed on the multimeter.
6.3 AC/DC Current Measurement
CAUTION: Never connect the multimeter in parallel to a voltage source when measuring current. This can damage the meter and cause injury.
- Turn off power to the circuit.
- Connect the black test lead to the COM jack. Connect the red test lead to the mA jack for currents up to 600mA.
- Press the mA~ / mA= Button to select AC or DC current mode.
- Break the circuit and connect the multimeter in series with the load.
- Restore power to the circuit and read the current value.

Image: Example of AC/DC Current measurement displayed on the multimeter.
6.4 Resistance Measurement
- Connect the black test lead to the COM jack and the red test lead to the INPUT jack.
- Press the Ω / ⟛ / )) Button to select Resistance mode (Ω).
- Ensure the circuit is de-energized before connecting the probes across the resistor or component.
- Read the resistance value on the display.

Image: Example of Resistance measurement displayed on the multimeter.
6.5 Capacitance Measurement
- Connect the black test lead to the COM jack and the red test lead to the INPUT jack.
- Press the Ω / ⟛ / )) Button repeatedly until Capacitance mode is selected.
- Discharge the capacitor completely before connecting the test probes across its terminals.
- Read the capacitance value on the display.

Image: Multimeter performing a capacitance test on a large capacitor, showing the measurement on the display.
6.6 Temperature Measurement
- Connect the temperature probe to the INPUT and COM jacks (observing polarity if applicable for your probe type).
- Press the °F / °C Button to select temperature mode.
- Place the tip of the temperature probe on or in the object whose temperature you wish to measure.
- Read the temperature value on the display. Use the °F / °C button to switch units.

Image: Multimeter measuring the temperature of water using the included temperature probe.
6.7 Diode and Continuity Test
- Connect the black test lead to the COM jack and the red test lead to the INPUT jack.
- Press the Ω / ⟛ / )) Button repeatedly to select Diode (⟛) or Continuity ())) mode.
- For Diode Test: Connect the probes across the diode. The display will show the forward voltage drop. Reverse the probes to check for open circuit.
- For Continuity Test: Connect the probes across the circuit or component. A continuous beep indicates continuity (low resistance).

Image: Multimeter performing an on-off (continuity) detection, showing a reading of 000.0 and a continuity symbol.
6.8 NCV (Non-Contact Voltage) Detection
- Press the NCV Button to activate NCV mode.
- Place the NCV sensor (usually at the top of the multimeter) close to the AC current source or wire.
- The multimeter will indicate the presence of AC voltage with an alarm (beeping) and an analog bar display.

Image: Multimeter detecting non-contact voltage near a power strip, showing an analog bar indicator.
6.9 Live/Zero Wire Detection
- Connect the red test lead to the INPUT jack.
- Press the Live Button to activate Live Wire detection.
- Insert the red test lead into the neutral wire or the live wire of a socket.
- If it is the live wire, the buzzer will sound continuously. If there is no buzzer, it is a neutral wire or ground wire.

Image: Multimeter performing live/zero wire detection in a wall socket, indicating the live wire.
7. Maintenance
7.1 Cleaning
Wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. Keep the input terminals free of dirt and moisture.
7.2 Battery Replacement
When the low battery indicator appears on the display, replace the batteries immediately to ensure accurate readings. Refer to Section 5.1 for battery installation instructions.
8. Troubleshooting
- No display or faint display: Check battery level and replace if necessary. Ensure batteries are installed with correct polarity.
- Incorrect readings:
- Verify the correct function and range are selected.
- Check test lead connections and ensure they are not damaged.
- Ensure the circuit is de-energized for resistance and capacitance measurements.
- For current measurements, ensure the multimeter is connected in series.
- Buzzer not sounding during continuity test: Ensure continuity mode is selected. Check if the circuit has very high resistance or is open.
9. Specifications

Image: Detailed product parameter comparison for DM97S/S+ and DM97A/A+ models.
| Function | DM97S/DM97S+ | DM97A/DM97A+ |
|---|---|---|
| Mode | Smart Range | Auto Range |
| DC Current | 0~600mA | 0~600mA |
| AC Current | 0~600mA | 0~600mA |
| DC Voltage | 0~600V | 0~600V |
| AC Voltage | 0~600V | 0~600V |
| TEMP Probe | -20~1000°C / -4~1832°F | -20~1000°C / -4~1832°F |
| Room TEMP | ✔ | ✔ |
| Resistance | 0~10MΩ | 0~100MΩ |
| Capacitance | 1uF~6000uF | 100nF~100mF |
| Fuse blown reminder | ✔ | ✔ |
| Frequency | 40Hz~400Hz | 40Hz~400Hz |
| Max Counts | 9999 Counts | 9999 Counts |
| Other Function | LIVE function, On-off test, Diode, NCV, Flashlight, T-RMS, Backlight | |
| Dimensions | 180*120*40mm (approx.) | |
| Operating Temperature | 0 - 40 ℃ | |
| Certification | CE, FCC, RoHS | |
10. User Tips
- Buzzer Volume: If you require a particularly loud buzzer for continuity or live wire detection, please note that buzzer volume can vary between units. If you find the buzzer too quiet for your needs, consider using visual indicators on the display in conjunction with the audible alert.
- Smart vs. Auto Range: The DM97S/S+ models feature "Smart Range" for simplified operation, automatically detecting the measurement type. The DM97A/A+ models use "Auto Range" which automatically adjusts the scale for the selected measurement type. Both aim to provide ease of use.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.