JUNCTEK KL-F Series

Contents

JUNCTEK KL-F Series Bluetooth Battery Monitor User Manual

Models: KL110F, KL140F, KL160F

1. Introduction

The JUNCTEK KL-F series DC voltage and current meter/battery coulomb meter is a versatile instrument designed for accurately measuring various electrical parameters. It provides real-time monitoring of voltage, current, power, charge and discharge capacity, watt-hours, temperature, and battery life. This device supports mobile app control via Bluetooth, allowing for convenient data viewing, parameter setting, and firmware updates.

Key features include:

  • Accurate detection of various parameters.
  • Suitable for all kinds of batteries within the voltage measurement range.
  • Mobile control and firmware update capabilities.
  • Bidirectional current detection (charging/discharging).
  • Multi-protection functions (over-voltage, under-voltage, over-current, over-power, over-temperature).
  • Ultra-low power consumption.
  • Support for relay control (relay purchased separately).
  • One-key data clear.
  • V/A values online calibration.
Battery Monitor with mobile app interface showing voltage, current, power, and capacity readings.
Figure 1.1: Battery Monitor with mobile app interface displaying real-time data.
Video 1.1: Overview of the KL-F series Battery Monitor and its mobile app functionality.

2. Safety Instructions

Please read and understand all safety precautions before operating the device to prevent personal injury or damage to the meter and connected products.

General Safety Summary

  • Observe All Terminal Ratings: Always check ratings and markers before connecting the meter to avoid fire or shock hazards.
  • Use Proper Over-voltage Protection: Ensure no over-voltage reaches the product to prevent electric shock.
  • Do Not Operate Without Covers: Never operate the meter with its covers or panels removed.
  • Do Not Insert Anything Into the Air Outlet: Avoid inserting objects into the air outlet to prevent damage.
  • Avoid Circuit or Wire Exposure: Do not touch exposed junctions or components when the unit is powered on.
  • Do Not Operate With Suspected Failures: If any damage is suspected, have the meter inspected by JUNCTEK authorized personnel. All maintenance or replacements must be performed by authorized personnel.
  • Provide Adequate Ventilation: Ensure proper ventilation to prevent overheating. Regularly inspect the air outlet and fan.
  • Do Not Operate in Wet Conditions: To avoid short circuits or electric shock, do not operate the meter in a humid environment.
  • Do Not Operate in an Explosive Atmosphere: Never operate the meter in an explosive environment.
  • Keep Meter Surfaces Clean and Dry: Maintain clean and dry surfaces to prevent dust or moisture from affecting performance.
  • Prevent Electrostatic Impact: Operate in an electrostatic discharge protective environment. Ground internal and external conductors of cables before making connections.
  • Handle with Caution: Handle the device carefully during transportation to avoid damage to components.

Important Notices

  • Do not exceed the specified voltage and current range to prevent damage.
  • Ensure correct polarity; positive and negative poles cannot be reversed.
  • The meter's shell is fragile; avoid impacts or exposure to chemicals.
  • Store the meter in a dry environment at -25~50℃.
  • Do not attempt to disassemble the meter, as this will void the warranty. Repairs must be done by authorized personnel.
  • Avoid violent movement of the meter to prevent internal circuit damage. Contact the supplier if the meter malfunctions.

3. Package Contents

Upon receiving your KL-F series Battery Monitor, please inspect the packaging for any damage and verify the contents against the list below. If any items are missing or damaged, contact your JUNCTEK sales representative.

Standard Package Includes:

  • Battery Monitor (Main Unit) x 1
  • Sampler (Shunt) x 1 (Specific to model: 100A for KL110F, 400A for KL140F, 600A for KL160F)
  • 4P Connection Cable x 1
  • Temperature Sensor x 1
  • Sampler Mounting Plate x 1
  • 3P Terminal x 1
  • 3P Connection Cable x 1
  • Screws x 4
  • Spacers x 4
Components of the KL110F package including the battery monitor, 100A shunt, cables, and temperature sensor.
Figure 3.1: KL110F Package Contents.
Components of the KL140F package including the battery monitor, 400A shunt, cables, and temperature sensor.
Figure 3.2: KL140F Package Contents.
Components of the KL160F package including the battery monitor, 600A shunt, cables, and temperature sensor.
Figure 3.3: KL160F Package Contents.

4. Product Overview

4.1 Measurement Module

Diagram of the KL-F series battery monitor module with labeled ports.
Figure 4.1: KL-F Series Measurement Module.

The measurement module features several interfaces:

  • Indicator Light: Shows the output status.
  • 2-wire, 3-wire Power Supply Selector Switch: Toggle switch for selecting external power supply (3W) or self-powered (2W) mode.
  • Power Supply Interface: Includes battery positive (VSNS), external power supply positive (VEXT), and external power supply negative (GND).
  • 485 Communication Connection Interface: For connecting to a supervisor computer or other measurement modules. Internal order from left to right: B, A, GND, NC.
  • Display Reserved Interface: For connecting an optional display module. Internal order from left to right: B, A, GND, +5V.
  • Relay Output Control Interface: For connecting relays. Internal order from left to right: GND, OUT, VEXT.
  • Sampler Interface: Connects to the shunt to detect current. Internal order from left to right: VCC, GND, ISNS+, ISNS-.
  • External Temperature Measurement Interface: Connects to the temperature sensor. Internal order from left to right: TSNS, GND.

4.2 Sampler (Shunt)

Diagram of the shunt with labeled components like copper screw, washer, nut, and spring coil.
Figure 4.2: Sampler (Shunt) Components.

The shunt is made of pure copper for good conductivity, low heating, and low power consumption. It connects to the measurement module to detect current.

  • Battery Negative Terminal: The negative terminal of the battery is connected to the screw with the GND or BATT- mark.
  • Sampler Interface: Connects with the sampler interface of the measurement module for current measurement.

4.3 Dimensions

Dimension diagram for KL110F battery monitor and 100A shunt.
Figure 4.3: KL110F Dimensions.
Dimension diagram for KL140F battery monitor and 400A shunt.
Figure 4.4: KL140F Dimensions.

5. Installation and Wiring

Proper wiring is crucial for accurate measurement and safe operation. Refer to the diagrams below for connection instructions.

5.1 Self-Powered Wiring Method

This method is suitable if the battery voltage is between 10-120V during normal operation. Set the power selection switch to "2W".

  • Connect the positive terminal of the battery to the "VSNS" power interface.
  • Connect the negative pole of the battery to the screw marked "BATT-" on the sampler.
  • Connect the negative poles of the charger and load to the other screw of the sampler.
  • Ensure correct polarity; do not reverse connections.
Self-powered wiring diagram for the battery monitor.
Figure 5.1: Self-Powered Wiring Diagram.

5.2 External Power Supply Wiring Method

This method is used when the external power supply voltage is 0-120V. Set the power selection switch to "3W".

  • Connect the positive pole of the external power supply to the "VEXT" power interface.
  • Connect the negative pole of the external power supply to the "GND" power interface.
  • Connect the positive pole of the battery to the "VSNS" power interface.
  • Connect the negative pole of the battery to the screw marked "BATT-" on the sampler.
  • Connect the negative poles of the charger and load to the other screw of the sampler.
  • Ensure correct polarity; do not reverse connections.
External power supply wiring diagram for the battery monitor.
Figure 5.2: External Power Supply Wiring Diagram.

5.3 External Power Supply Wiring Method (Relay Control)

If using a relay for charging/discharging control, an external power supply with the same working voltage as the relay is required. Set the power selection switch to "3W".

  • Connect the control ports of the relay to the "OUT" and "VEXT" of the measurement module's Output Control.
  • Connect the positive pole of the external power supply to the "VEXT" of the Output Control.
  • Connect the negative pole of the external power supply to the "GND" of the Output Control.
  • The negative pole of the battery connects to the "BATT-" screw on the shunt.
  • The negative poles of the charger and load connect to the other screw on the shunt.
  • Ensure all positive and negative poles are connected correctly.
External power supply wiring diagram with relay control for the battery monitor.
Figure 5.3: External Power Supply Wiring Diagram (Relay Control).

6. Mobile App Setup and Operation

The KL-F series Battery Monitor can be controlled and monitored via a mobile application. Ensure your phone's Bluetooth and location services are enabled.

6.1 App Download and Installation

For Android:

  • Uninstall any previous versions of the app.
  • Download via Google Play: Google Play Link
  • Alternatively, download from the server: Direct APK Download
  • If unable to download, contact customer service.
  • The app supports Android 5.0 and above. Grant location service permissions during installation.

For iOS:

  • Search "KL series" in the Apple App Store.
  • The app supports iOS 9.0 and above. Grant Bluetooth access permissions.

6.2 Bluetooth Connection

  • Ensure Bluetooth and location services are enabled on your mobile phone.
  • Open the mobile app.
  • On the main screen, click the "Search" button (usually in the upper right corner) to find available Bluetooth devices.
  • Select the device (e.g., "BTGxxx") to connect. Once connected, "Connected" will appear, and the machine model will be displayed.
  • No pairing password is required, and no special pairing is needed in your phone's Bluetooth settings.
Mobile app interface showing real-time voltage, current, capacity, power, and temperature readings.
Figure 6.1: Mobile App Main Interface.

6.3 App Interface and Functions

The app provides a comprehensive interface for monitoring and controlling the battery monitor.

  • Interface Title Bar: Access main interface, system settings, and "About Us" sections.
  • Device ID: Displays after successful connection.
  • Communication Address: Range P00-P99.
  • Measured Voltage Value: Displays voltage from the power supply interface.
  • Remaining Battery Capacity: Calculated from charging/discharging (Preset capacity - Cumulative capacity).
  • Battery Capacity Percentage: Graphical representation of remaining capacity.
  • Preset Battery Capacity: Set the total capacity of your battery.
  • Ambient Temperature: Displays temperature from the external sensor.
  • Battery Life: Estimates battery life and charging time based on the charge and discharge current and capacity.
  • Bluetooth Switch: Connect/disconnect the Bluetooth module.
  • Product Model: Displays the connected device's model.
  • Control State: Controls the output state.
  • Measured Current Value: Displays actual current. Green for charging, brown for discharging.
  • Power: Measured current power in Watts.
  • Power Consumption: Accumulated electrical energy in kW.h.
  • Clear Data: Clears time, power consumption, and accumulated capacity data.
  • Cumulative Capacity: Accumulated charging/discharging capacity.

6.4 Main Interface Operations

  • Output State Control Switch: Controls the output state. Different states are displayed under various protection conditions.
  • Voltage/Current Fine Adjustment: Click on the voltage/current value to open a calibration pop-up. Default calibration is 100.
  • Voltage/Current Scale Range: Click on the voltage/current dial to adjust the display scale.
  • Clear Data: Click the "Clear data" button to reset accumulated data.
  • Percentage of Remaining Capacity: Click the battery icon to set the remaining capacity percentage.
  • Preset Battery AH Value: Click the "setting" button next to preset battery AH value to input the battery's total capacity.
  • Ambient Temperature Calibration/Unit: Click on the ambient temperature to fine-tune or switch between Celsius/Fahrenheit.

6.5 System Settings Operations (Protection Functions)

Access the "Settings" menu to configure protection functions. A relay (purchased separately) is required for these functions to actively control the circuit.

Diagram illustrating comprehensive protection features: OVP, LVP, OTP, OCP, NCP, OPP.
Figure 6.2: Comprehensive Protection Features.
  • Over Voltage Protection (OVP): Set a maximum voltage. If exceeded, the output will turn off.
  • Under Voltage Protection (LVP): Set a minimum voltage. If dropped below, the output will turn off.
  • Discharge Overcurrent Protection (OCP): Set a maximum discharge current. If exceeded, the output will turn off.
  • Over Temperature Protection (OTP): Set a maximum temperature. If exceeded, the output will turn off.
  • Over Current Protection (OCP - Positive): Set a maximum charging current. If exceeded, the output will turn off.
  • Over Power Protection (OPP): Set a maximum power. If exceeded, the output will turn off.
  • Low Temperature Protection (LTP): Set a minimum temperature. If dropped below, the output will turn off.
  • Protection Recovery Time: Set the delay before the output recovers after a protection event.
  • Delay Time Setting: Set a delay for protection activation.
  • Relay Mode: Select normally open or normally closed based on your relay type.
  • Low Capacity Reminder: Set a percentage for a low capacity alert.

6.6 Firmware Upgrade

The device supports firmware upgrades via the mobile app. This is important for new features and bug fixes.

  • Navigate to "Settings" -> "After-sales Service" in the app.
  • Enter code "8610" to access "Firmware Upgrade".
  • Enter firmware code "000" and click OK.
  • Important: For products ordered before January 1, 2022, power off the product, then power it on while short-circuiting the temperature measurement interface before starting the upgrade.
  • Wait for the upgrade to complete and confirm "Upgrade Successful" before exiting the app.
Video 6.3: Demonstration of product features and application scenarios, including app usage.

7. Technical Specifications

Parameter KL110F KL140F KL160F
Sampling methodShuntShuntShunt
Voltage measurement range (External power supply)0-120V0-120V0-120V
Voltage measurement range (Self-powered)10-80V10-80V10-80V
Voltage resolution0.01V0.01V0.01V
Current measurement range0-100A0-400A0-600A
Current resolution0.01A0.1A0.1A
RelayOptional (need to be purchased separately)
Temperature measurement range-20-120℃
Capacity display range0%~100%
Power measurement range0~72KW
Power resolution0.01W
Amp-hour measurement range0~9999.99AH
Capacity resolution0.001AH
Watt-hour measurement range0~9999.99kWH
Watt-hour accuracy0.001WH
Time measurement range0~999:59:59S
Time resolution1 second
Bluetooth communication distance10m
Voltage accuracy±1%+2 characters
Current accuracy±1%+5 characters
Sampling rate1 time/second
Measuring module power consumptionAbout 0.4W
Over power protection0-99999.99W
Negative overcurrent protection0~100A0~400A0~600A
Forward overcurrent protection0~100A0~400A0~600A
Overvoltage protection0-120V
Undervoltage protection0-120V
External over temperature protection0-120℃
Protection recovery time0-99s
Enter standby time0-60s
Delay time setting0-99S
Mailing address99 P01-P99, P00 is broadcast address

8. Troubleshooting

If you encounter any issues with your KL-F series Battery Monitor, please follow these steps. If the problem persists, contact JUNCTEK support.

Mobile App Cannot Connect to Bluetooth / No Display After Power On:

  1. Check whether the power supply and measurement module are well connected.
  2. After performing the above inspection, restart the instrument.
  3. If the product still cannot be used normally, contact JUNCTEK support.

9. User Tips

  • Always turn on Bluetooth on your phone before launching the app for a smoother connection.
  • If you have trouble with the Android app, note that there might be different versions (e.g., "KG" vs. "KL"). Try searching for "KL-F" in the Play Store and look for the app with the VA logo.
  • The device operates via Bluetooth, not Wi-Fi, for remote monitoring.
  • The device itself has a very low current consumption (about 0.4W), so it won't significantly drain the battery it's monitoring.
  • All KL-F series models (KL110F, KL140F, KL160F) include Bluetooth connectivity and battery capacity monitoring.

10. Warranty and Support

JUNCTEK products are covered by P.R.C. patents. This document replaces all previously published documentation.

Contact Us:

If you have any problems or requirements regarding our products or this manual, please contact JUNCTEK:

Additional Resources:


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.