HXCONTROLLER 2800W Hybrid Wind Solar Controller

Contents

MPPT Hybrid Wind Solar Charge Controller Regulator User Manual

Model: 2800W Hybrid Wind Solar Controller

General Safety Information

Thank you for purchasing our product. This manual provides essential information for installing and operating the controller. Please read it thoroughly before any work and keep it for future reference. Product specifications and content may be updated periodically without notice.

  • Inspection: Before installation, carefully check the product for any transport damage. Contact the shipping company or our company immediately if damage is found.
  • Professional Installation: All installation and electrical work must be performed by qualified professional personnel.
  • No Disassembly: Do not disassemble or attempt to repair the controller without professional guidance.
  • Battery Connection: Do not use the controller without batteries. Do not disconnect the controller and batteries while the controller is operating normally.
  • Child Safety: Keep children away from the controller.
  • Environmental Protection: Do not allow water to enter the controller.
  • Secure Connections: Ensure all power connections are tightened to prevent excessive heating from loose connections. Use cables suitable for your system.

Product Introduction

This MPPT Hybrid Wind Solar Charge Controller is specifically designed for small off-grid wind and solar power systems, such as street lamps or monitoring systems, to safely and efficiently charge batteries. It supports Lithium, LiFePO4, GEL, and Lead-acid batteries and features comprehensive charge and discharge protection.

Functions and Features

  • Wind Generator MPPT Boost Charging: Maximizes power harvest from wind turbines.
  • PWM Dump Load: Features external dump-load resistance and intelligent disconnection of solar charging to prevent overcharging.
  • Dual Power Supply: Operates using both battery and solar power.
  • LCD Display: Conveniently displays parameters such as voltage and current for wind, solar, and load. Users can adjust certain parameters.
  • DC Output Modes: Provides 3 different DC output modes.
  • Enhanced Durability: The internal circuit board is sprayed with conformal coating to protect against dust, moisture, and static electricity.

Built-in Smart Bluetooth Device

The controller includes a built-in Bluetooth module, eliminating the need for additional devices. Simply enable Bluetooth on your Android mobile phone and download the dedicated APP to connect. The APP allows you to monitor the controller's working conditions, including wind energy, solar energy, and battery voltage/current, and identify any abnormalities. The effective monitoring range is within 200 meters. Note: Currently, the Bluetooth APP only supports Android systems, not iOS.

Screenshot of the Bluetooth mobile application showing controller data

Bluetooth mobile application interface for monitoring controller data.

LCD Screen Display Information

  • English language display.
  • Battery voltage and power.
  • Photovoltaic voltage, current, and power.
  • Wind turbine voltage, current, and power.
  • Cumulative power generation.
  • Over voltage and overdischarge voltage data are freely settable.

Setup

Mounting Notes

  • Read this entire section before installation.
  • All mounting work must be performed by professional personnel.
  • Disconnect all power sources to the controller before installing or adjusting.
  • Do not allow water or snow to enter the controller.
  • Keep away from corrosive gases and strong electromagnetic interference.
  • The installation site should allow for convenient installation, electrical connection, and future maintenance.
Diagram showing the dimensions of the MPPT Wind/Solar Hybrid System Controller

Controller dimensions: 145mm/5.7inch (width) x 171mm/2.4inch (height) x 67mm/2.7inch (depth).

Wiring Steps

Follow these steps carefully for proper connection. Refer to the video below for a visual guide on connecting the controller.

Video demonstrating the unboxing and connection process of the hybrid controller.

Overall system wiring diagram for MPPT Wind/Solar Hybrid System Controller

Overall system wiring diagram showing connections for wind turbine, solar panel, controller, battery, inverter, and AC load.

2.2.1 Dump Load Wiring

Connect the dump load positive (+) and negative (-) terminals to the corresponding ports on the controller as shown in the diagram.

Image of the dump load resistor

External dump load resistor.

2.2.2 Load Wiring

Connect the load positive (+) and negative (-) terminals to the controller. Ensure no short circuits occur during wiring. Anti-connecting positive (+) and negative (-) is forbidden. The load current should not exceed the rated load current of the controller.

2.2.3 Battery Wiring

Connect the battery positive (+) and negative (-) terminals to the controller. Be cautious as the solar PV array can produce high voltages in sunlight, posing a risk of electric shock. Although the controller has reverse polarity protection, anti-connecting positive (+) and negative (-) is forbidden.

2.2.4 Solar Wiring

Connect the solar panel positive (+) and negative (-) terminals to the controller. The solar PV array can produce high voltages in sunlight, so exercise caution to avoid electric shock. Anti-connecting positive (+) and negative (-) is forbidden.

2.2.5 Wind Generator Wiring

Connect the wind generator to the controller. Wind generators can produce high voltages, so be careful to avoid electric shock. It is safer to connect the wind generator when there is little to no wind. Only connect a high-speed rotating wind generator after the controller is fully operational.

Operation

Button Descriptions

ButtonDescriptionNote
ENTERLong press (3 seconds) to enter parameter setting interface or save parameters and exit. Short press to switch to the next setting item.If no key is pressed for 1 minute, modified parameters will not be saved.
UPBrowse previous item. Increase parameter value (long press for fast adjustment).
DOWNBrowse next item. Decrease parameter value (long press for fast adjustment).
ESCReturn to main browsing interface. Long press (3 seconds) to exit setting state without saving. Long press (5 seconds) in main interface to switch to Chinese.

Browsing Interfaces

After powering on, the LCD will display the default parameter browsing interface. You can navigate through various items using the UP and DOWN buttons to view the status information of the battery, solar panels, wind turbine, load, and temperature.

Display Icons and Meanings

  • Day: Indicates daytime operation.
  • Night: Indicates nighttime operation (also displayed if no PV is connected).
  • Wind Turbine: Icon shows wind turbine charging when rotating.
  • Charge: Arrow flash indicates PV and wind turbine are charging normally.
  • Brake: Wind turbine brake is active, usually for 10 minutes.
  • Battery Pattern: Shows battery power level. Flashes during over-discharge protection and returns to normal when voltage is higher than recovery voltage.
  • Output: Arrow flash indicates controller load output is normal.
  • BAT: Displays current browsing content parameters.

Parameter Display Content

BatteryPVWind TurbineLoadTemperature
V-Battery VoltageV-PV VoltageV-wind turbine voltageMODE-output operation loadsController Temperature
%-Battery CapacityA-PV currentA-wind turbine currentW-load powerP-Temperature code
A-Battery CurrentW-PV powerW-wind turbine powerA-load current
W-Battery PowerL0-Load fault code
KWH-cumulative output

Load and Temperature Code Meanings

Load CodeDescriptionTemperature CodeDescription
L0NormalP0Normal
L1Manual closing stateP1Low temperature state
L2Over discharge protectionP2High temperature state
L3Over current protectionP3Protection state
L4Over voltage protectionP4Abnormal

Parameter Setting

  • Enter Setting: Long press the ENTER key for more than 3 seconds from any browsing interface.
  • Navigate Items: Press ENTER to move to the next parameter setting item. Press ESC to move to the previous item.
  • Adjust Values: When a parameter is flashing, press UP to increase the value (long press for rapid increase) or DOWN to decrease the value (long press for rapid decrease).
  • Save & Exit: After setting parameters, long press ENTER for more than 3 seconds to save and exit.
  • Exit Without Saving: After setting parameters, long press ESC for more than 3 seconds to exit without saving.

Settable Parameters Overview

ItemDisplayMeaningOptions / Notes
1SYS 12/24 AUTORated voltage of battery12: lock 12V system; 24: lock 24V system; AUTO: automatic recognition
2TYPE: b0Type of batteryb0: customization; b1: Gel battery; b2: Ternary lithium battery; b3: Lithium iron phosphate battery. When set to b0, each voltage can be set by the users. When set to b1/b2/b3, the controller automatically matches the default value.
3LOW: ***VOver discharge protection voltage
4RLOW: ***VOver discharge recovery voltage
5FULL: ***VOver charge protection voltage
6UL: **VLight control voltageVoltage to judge day/night. 1 minute delay.
7ON/OFFSolar charge switch
8ON/OFFWind turbine charge switch
9ON/OFFLoad output switch
10MODE: *Load modeMODE 1: light control (load off day, on night 100% power). MODE 2: Always on (100% power). MODE 3: Light control + time control (load on at dark, work according to set time/power, four sections + morning light mode adjustable).
11T1: ***minFirst time phaseTime phase and power of load can be adjusted. Each time phase is adjustable from 0 to 900 minutes and power is 0-100%.
12P1: ***%Power in first time phase
13T2: ***minSecond time phase
14P2: ***%Power in second time phase
15T3: ***minThird time phaseIn Mode 3, if the first working time is set to 2 minutes and the first power is 0%, the system will delay 2 minutes before turning on the light after dark.
16P3: ***%Power in third time phase
17T4: ***minForth time phase
18P4: ***%Power in forth time phase
19TC: ***minMorning time phaseThis function can eliminate the difference between front and rear lights caused by solar panels of different street lamps, to achieve simultaneous lighting.
20PC: ***%Power in time phase

Troubleshooting

SymptomPossible Cause & Solution
Wind generator speed becomes very slow immediately after connecting to controller.
  1. Battery voltage has reached float charge voltage.
  2. Rated output voltage of wind generator is much higher than battery voltage. The wind generator speed is proportional to output voltage, and the voltage is dragged by the battery, resulting in very low speed.
  3. The dump load MOS was burnt out due to incorrect operation.
Wind generator dumps load when controller displays small current.The controller protects the system by detecting battery voltage, charging current, and temperature. When the battery reaches float charge voltage or high temperature, the wind generator will dump load regardless of charging current.
LCD does not display.
  1. Battery not connected properly to the controller. Check battery and controller connections.
  2. Battery is damaged. Check and replace the battery.
No charging current.Charging only occurs when the input voltage of solar panels and/or wind generator is higher than the battery voltage.

Specifications

FeatureDescription
Brand NameHXCONTROLLER
Model Number2800W 2000W 1400W 1200W Hybrid Wind Solar Controller
Is Smart DeviceYes (Built-in Bluetooth)
ApplicationCharger Controller, Voltage Controller, Wind Controller, Solar System Controller
Maximum Current60A
CertificationCE, FCC
Suggestion Wind Generator Power0-1600W
Suggestion Solar Power600W-1200W
Battery Voltage12V or 24V 48V
System Rated Voltage12/24/48V Auto Match
Wind Turbine Workable PowerMAX 1600W
Solar Module Workable PowerMAX 1200W
Max Input Voltage (Wind Turbine)<80V
Max Input Voltage (Solar Panel 12/24V)≤55V
Max Input Voltage (Solar Panel 24/48V)≤95V
No-load Current (DC)≤0.05A
Controller Power ModeBattery or Solar
Control ModeWind generator MPPT boost charge, PWM dump load, PWM Over current Limiting function. Solar power module is PWM.
Output Working ModeMode 1: Light-control on. Light-control off (3 modes adjustable)
Protection TypeSolar Reversed Charging protection, Battery open circuit protection, Battery anti-reverse connection protection, Over current and over voltage auto brake protection, Over load protection, Lightning Protection.
Cooling ModeAluminium profiles Heat dissipation and self-cooling
Working Temperature / Relative Humidity-25°C~+80°C / 0~90%, non-condensing
Net Weight / Gross Weight2.35KG / 2.85KG
Controller Size / Pack Size167mm*145.5mm*61.8mm / 360mm*250mm*120mm

Battery Parameter Reference Table

Special Note: This controller does not have a one-key restore function. Please do not modify preset parameters unless you fully understand the implications.

12V/24V System Battery Parameters

Battery TypeFULL (Over Charge)LOW (Load Disconnect)RLOW (Load Connect)
Customization (b0)14.7V/29.4V (Adjustable)10.2V/20.4V (Adjustable)11.5V/23.0V (Adjustable)
Lead acid/Gel Battery (b1)14.4V/28.8V (Default)10.2V/20.4V (Default)11.5V/23.0V (Default)
Ternary lithium battery (b2)12.6V/25.2V (Default)9.0V/18.0V (Default)10.0V/20.0V (Default)
Lithium iron phosphate (LiFePO4) (b3)14.4V/28.8V (Default)10.0V/20.0V (Default)11.0V/22.0V (Default)

24V/48V System Battery Parameters

Battery TypeFULL (Over Charge)LOW (Load Disconnect)RLOW (Load Connect)
Customization (b0)29.4V/58.8V (Adjustable)20.4V/40.8V (Adjustable)23.0V/46.0V (Adjustable)
Lead acid/Gel Battery (b1)29.4V/58.8V (Default)20.4V/40.8V (Default)23.0V/46.0V (Default)
Ternary lithium battery (6S/13S) (b2)25.2V/54.6V (Default)18.0V/39.0V (Default)20.0V/43.4V (Default)
Lithium iron phosphate (LiFePO4) (8S/16S) (b3)28.8V/57.6V (Default)20.0V/40.0V (Default)22.0V/44.0V (Default)

Maintenance

Regular maintenance ensures the longevity and optimal performance of your hybrid controller. Always disconnect all power sources before performing any maintenance.

  • Check Connections: Periodically inspect all wiring connections for tightness and signs of corrosion. Loose connections can lead to overheating and system malfunction.
  • Cleanliness: Keep the controller free from dust and debris. Use a soft, dry cloth for cleaning. Do not use liquids or abrasive cleaners.
  • Environmental Conditions: Ensure the controller remains in a dry, well-ventilated environment, away from direct sunlight, rain, snow, corrosive gases, and strong electromagnetic interference.
  • Battery Health: Regularly check the battery's condition. If the battery does not work properly after correct connection, it may need replacement.
  • Fuse Inspection: If the controller does not display or function after correct battery connection, check the internal fuse and replace if necessary.

User Tips

  • Solar Panel Voltage Limits: For a 24V system, ensure your solar panel voltage does not exceed 55V. For a 48V system, ensure it does not exceed 95V. Exceeding these limits can damage the controller's MOS tube.
  • MPPT Start Voltage for Wind Generator: For a 12V battery system, the wind generator voltage needs to reach at least 8V to start MPPT charging. For a 24V system, it needs 16V, and for a 48V system, it needs 32V.
  • Bluetooth App Compatibility: The built-in Bluetooth feature currently supports Android devices only.
  • Battery Equalizer: To extend battery life and prevent issues from inconsistent battery voltage in series-connected battery packs, consider using a battery equalizer.
Diagram illustrating how a battery equalizer balances charge and discharge across battery cells

Battery Equalizer: Balances battery cells during charging and discharging to prevent premature battery failure.

Image of a battery balancer product with wiring

Example of a Battery Balancer product.

Warranty Information

This product comes with a one-year warranty from the date of shipment to the original end-user. During the warranty period, if a failure occurs under normal use, our company will repair or replace the product free of charge. After the warranty period, repair services are available for a fee.

Important Notes:

  • This warranty is only provided to the original buyer who purchased the product directly from us and is non-transferable.
  • Our company reserves the right to change products and update specifications without prior notice.
  • The warranty does not cover failures resulting from:
    • Operation not in accordance with this user manual.
    • Accident, negligence, abuse, or improper use.
    • Unauthorized product modification or attempted repair.
    • Damage occurring during shipment.

Support

For further detailed instructions and diagrams, you may refer to the comprehensive user manual available in PDF format. This document contains additional technical information and troubleshooting guides.

A PDF version of this manual is available for download: User Manual (PDF)

For any inquiries or technical assistance not covered in this manual, please contact our customer support.

CE Certification document for Solar Charge Controller

CE Certificate of Compliance.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.