1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of the KKMOON FH8-6CRRB Dual Display Digital Counter. This versatile device functions as both an industrial counter for batch and production line object counting, and a length meter. It is designed for wide application in various industries including machine manufacturing, light industry, electronics, food processing, packaging, leather, and cloth weaving.

2. Safety Information
Please read and understand all safety instructions before installing or operating the device. Failure to follow these instructions may result in electric shock, fire, or personal injury.
- Ensure the power supply is disconnected before any wiring or maintenance.
- Only qualified personnel should perform installation and wiring.
- Do not operate the device in environments with excessive moisture, dust, or corrosive gases.
- Verify all connections are correct and secure before applying power.
- Do not disassemble or modify the device; refer all servicing to qualified personnel.
3. Product Features
- Dual 6-digit light-emitting diode (LED) display for clear reading of Present Value (PV) and Preset Value (SV).
- Switchable NPN and PNP sensor input compatibility.
- Offers 4 distinct input modes and 6 different output modes for versatile application.
- Optional isolated input and output for enhanced electrical safety and noise reduction.
- Wide counting range: -199999 to 999999.
- Adjustable preset range: 0.00001 to 999999.
- Ability to set alarm values for relay output.
- Compatible with various sensors including encoders, proximity switches, photoelectric switches, optical sensors, and laser sensors.
4. Setup and Installation
4.1 Unpacking and Inspection
Carefully unpack the digital counter and inspect for any signs of damage. Ensure all components are present:
- 1 x FH8-6CRRB Digital Counter
- 2 x Mounting Brackets
- 1 x User Manual (English)
4.2 Dimensions
The physical dimensions of the counter are important for proper installation and panel cutout. Refer to Figure 2 for detailed measurements.

- Item Size: 9.5 cm (3.74 in) x 8.5 cm (3.35 in) x 4.7 cm (1.85 in) (Width x Depth x Height)
4.3 Mounting
The counter is designed for panel mounting. Use the provided brackets to secure the device into a suitable panel cutout. Ensure adequate ventilation around the unit.
4.4 Wiring Diagram
Refer to the wiring diagram below (Figure 3) for correct electrical connections. Ensure all connections are made securely and according to local electrical codes.

Terminal Descriptions:
- Terminals 1 & 2: Power Supply (90-265V AC/DC)
- Terminals 3, 4, 5: RELAY Alarm Output (OUT1, OUT2, Common)
- Terminal 8: 24V DC Auxiliary Power Output
- Terminal 9: RESET Terminal
- Terminal 10: GND Terminal
- Terminal 11: B Input (for pulse signals, e.g., from encoder)
- Terminal 12: A Input (for pulse signals, e.g., from encoder)
Important: The input pulse signal should be Square Wave or Sine Wave: 5V ≤ H ≤ 30V, 0 ≤ L ≤ 2V, with up edge active. Input impedance is ≥10KΩ.
5. Operation
5.1 Front Panel Controls and Display
The front panel features a dual LED display and several control buttons. Refer to Figure 4 for an overview.

- PV (Present Value): The upper display shows the current count value measured by the sensor.
- SV (Preset Value): The lower display shows the preset value for output control or output percentage.
- SET Key: Used to enter or exit the program menu and confirm preset values.
- /RST Key: Resets the counter.
- UP Arrow Key: Increases the displayed value during setting.
- DOWN Arrow Key: Decreases the displayed value during setting.
- Shift/Autotune Key: Used for data shifting. Press and hold for more than 3 seconds to initiate auto-tuning.
- Indicator Lamps (OUT1, OUT2, BT/SV2):
- OUT1: Indicates output 1 status (ON: active, OFF: inactive).
- OUT2: Indicates output 2 status (ON: active, OFF: inactive).
- BT: Batch display lamp.
- SV2: No function.
5.2 Basic Counting
Once powered on and sensors are correctly connected, the counter will begin counting based on the configured input mode. The Present Value (PV) will update in real-time.
5.3 Setting Preset Values
To set a preset value (SV):
- Press the SET key to enter the setting mode.
- Use the UP and DOWN arrow keys to adjust the digits of the Preset Value (SV).
- Use the Shift/Autotune key to move between digits.
- Press the SET key again to confirm the value and exit the setting mode.
When the Present Value (PV) reaches the Preset Value (SV), the corresponding relay output (OUT1 or OUT2, depending on configuration) will activate.
5.4 Input and Output Modes
The FH8-6CRRB supports 4 kinds of input modes and 6 kinds of output modes. Specific details on configuring these modes are typically found within the device's programming menu, accessed via the SET key. Refer to the full user manual (if available) for advanced configuration options.
6. Maintenance
- Cleaning: Use a soft, dry cloth to clean the display and casing. Do not use abrasive cleaners or solvents.
- Inspection: Periodically check all wiring connections for tightness and signs of wear or damage.
- Environment: Ensure the operating environment remains within the specified temperature and humidity ranges to prolong the device's lifespan.
7. Troubleshooting
If you encounter issues with your digital counter, consider the following steps:
- No Display/Power:
- Check the power supply connections (Terminals 1 & 2).
- Ensure the input voltage is within the 90-265V AC/DC range.
- Incorrect Counting:
- Verify sensor connections (Terminals 11 & 12 for A/B Input).
- Check sensor type (NPN/PNP) and ensure it matches the counter's configuration.
- Confirm the input signal characteristics (5V≤H≤30V, 0≤L≤2V, up edge active).
- Ensure the counting speed (30/5000CPS) is not exceeded by the sensor's pulse rate.
- Relay Output Not Activating:
- Check relay output connections (Terminals 3, 4, 5).
- Verify the preset value (SV) is correctly set.
- Ensure the output mode is configured appropriately.
- Device Not Responding to Buttons:
- Ensure the device is not in a locked mode (if applicable, refer to advanced settings).
- Try a power cycle (turn off and on).
If the problem persists after attempting these steps, please contact customer support.
8. Specifications
| Parameter | Value |
|---|---|
| Model Number | FH8-6CRRB |
| Type | 6-digit Counter / Length Meter |
| Material | ABS |
| Voltage | 90~265V AC/DC |
| Auxiliary Power | 24V DC |
| Input Signal | Pulse Signal: Square Wave and Sine Wave: 5V≤H≤30V 0≤L≤2V up edge active |
| Input Impedance | ≥10KΩ |
| Counting Speed | 30/5000CPS |
| Counting Range | -199999~999999 |
| Preset Range | 0.00001-999999 |
| Response Speed | Switch type input 0~5000Hz, Incremental encoder input 0~2000Hz |
| Accuracy | ±0.1%F.S |
| Output | 2 Relay Contact Output |
| Environment Temperature | 0~50℃ |
| Storage Temperature | -10~60℃ |
| Environment Humidity | 35~85%RH |
| Insulation Resistance | ≥10MΩ |
| Power Consumption | ≤5W |
| Contact Edge | Up edge active |
| Item Size (W x D x H) | 9.5 x 8.5 x 4.7 cm / 3.74 x 3.35 x 1.85 in |
| Item Weight | 167g / 5.89oz |
9. User Tips
- This device is primarily a 6-digit counter, suitable for applications requiring precise counting and length measurement.
- For optimal performance, ensure your sensors (encoder, proximity switch, etc.) are correctly calibrated and provide a clean pulse signal within the specified voltage range.
- When setting preset values, use the Shift key to navigate between digits for quicker input.
10. Warranty & Support
This product comes with a 1-year guarantee from the date of purchase. This warranty covers defects in materials and workmanship under normal use.
For warranty claims, technical support, or any questions not covered in this manual, please contact your retailer or the manufacturer's customer service. Please have your model number (FH8-6CRRB) and purchase details ready when contacting support.